100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Home inspector test Exam Questions With Correct Answers 100% Verified.

Puntuación
-
Vendido
-
Páginas
9
Grado
A+
Subido en
10-02-2025
Escrito en
2024/2025

©THESTAR 2024/2025 ALL RIGHTS RESERVED 11:42PM. A+ 1 Home inspector test Exam Questions With Correct Answers 100% Verified. Which of the following soils can support the least load-bearing pressure? - AnswerSilt with high compressibility In general, the grading around a building should be positively sloped for how many feet away from the building? - Answer10 feet Flashing is not required at which of the following locations? - AnswerAbove projecting masonry Under which of the following conditions is a two-coat stucco system acceptable on the exterior of a building? - AnswerIf the system is installed over masonry or concrete Which of the following locations is the worst place to cut a hole in an I-joist? - AnswerNear the end of the joist in the web Why must building footings extend below the frost line? - AnswerSo that the soil around the footing does not freeze, expand, and cause the footing to shift Which of the following locations does not require a GFCI outlet? - AnswerReceptacles that serve appliances Which of the following is a way that many homes' electrical systems are grounded? - AnswerThrough a connection to the cold water piping What are the types of heat that must be taken into account when calculating the cooling loads for an HVAC system? - AnswerSensible and latent heat How many BTU's per hour is a ton of cooling capacity in HVAC equipment equal to? - Answer12,000 btu per hour A gas furnace is being installed in a brand new building. What is the most likely reason that an outdoor air source would be required? - AnswerThe building has unusually tight construction ©THESTAR 2024/2025 ALL RIGHTS RESERVED 11:42PM. A+ 2 What is the purpose of an expansion tank in a hot water system? - AnswerIt allows the water to expand as it warms without increasing the pressure in the system Which of the following is not a code requirement for electric clothes dryer exhaust ducts? - AnswerThe diameter of the duct must be per the manufacturer's requirements but not less than 6" The utility bills for heating and cooling a home are much higher than expected. Which of the following choices is probably not a reason for this increased cost? - AnswerThe fresh air intake for the HVAC system is incorrectly sized Which of the following would be most likely to have the highest R-value? - Answer6" fiberglass batt insulation Which of the following is not a form of home inspection report? - AnswerDisclaimer The home inspection report should be delivered to the client: - AnswerAfter the report has been finalized by the home inspector Home inspectors must inspect the low voltage wiring. True or false ? - AnswerFalse Home inspection standards generally require that the inspector test the drinking water quality. True or false - AnswerFalse A typical exterior inspection includes an examination of the shutters, if they are part of the structure. True or false - AnswerFalse Home inspectors must inspect readily accessible systems. True or false - AnswerTrue An example of a latent defect is a cracked sewer drain under the foundation. True or false - AnswerTrue What is the minimum allowed slope of graded soil next to a building's foundation, according to the International Residential Code (IRC)? - Answer¥ 6"/10' Which of the following is not a solid fuel heating device? - AnswerElectrical heater Every basement and sleeping room is required to have an easily operable emergency escape window. How large must this window be? - AnswerAt least 5.7 sq. ft The roofing material on a house or other building is considered a part of the roof drainage system. True or false - AnswerFalse You are inspecting a residential property. You have to observe and/or test all of the readily accessible components of each system. Determine which of the following is not considered to be a readily accessible component of a

Mostrar más Leer menos
Institución
Home Inspector
Grado
Home inspector









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Home inspector
Grado
Home inspector

Información del documento

Subido en
10 de febrero de 2025
Número de páginas
9
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

©THESTAR 2024/2025 ALL RIGHTS RESERVED 11:42PM. A+




Home inspector test Exam Questions With
Correct Answers 100% Verified.



Which of the following soils can support the least load-bearing pressure? - Answer✔Silt with
high compressibility
In general, the grading around a building should be positively sloped for how many feet away
from the building? - Answer✔10 feet

Flashing is not required at which of the following locations? - Answer✔Above projecting
masonry
Under which of the following conditions is a two-coat stucco system acceptable on the exterior
of a building? - Answer✔If the system is installed over masonry or concrete

Which of the following locations is the worst place to cut a hole in an I-joist? - Answer✔Near
the end of the joist in the web

Why must building footings extend below the frost line? - Answer✔So that the soil around the
footing does not freeze, expand, and cause the footing to shift

Which of the following locations does not require a GFCI outlet? - Answer✔Receptacles that
serve appliances
Which of the following is a way that many homes' electrical systems are grounded? -
Answer✔Through a connection to the cold water piping
What are the types of heat that must be taken into account when calculating the cooling loads
for an HVAC system? - Answer✔Sensible and latent heat
How many BTU's per hour is a ton of cooling capacity in HVAC equipment equal to? -
Answer✔12,000 btu per hour
A gas furnace is being installed in a brand new building. What is the most likely reason that an
outdoor air source would be required? - Answer✔The building has unusually tight construction



1

, ©THESTAR 2024/2025 ALL RIGHTS RESERVED 11:42PM. A+


What is the purpose of an expansion tank in a hot water system? - Answer✔It allows the water
to expand as it warms without increasing the pressure in the system
Which of the following is not a code requirement for electric clothes dryer exhaust ducts? -
Answer✔The diameter of the duct must be per the manufacturer's requirements but not less
than 6"
The utility bills for heating and cooling a home are much higher than expected. Which of the
following choices is probably not a reason for this increased cost? - Answer✔The fresh air
intake for the HVAC system is incorrectly sized

Which of the following would be most likely to have the highest R-value? - Answer✔6"
fiberglass batt insulation

Which of the following is not a form of home inspection report? - Answer✔Disclaimer

The home inspection report should be delivered to the client: - Answer✔After the report has
been finalized by the home inspector

Home inspectors must inspect the low voltage wiring. True or false ? - Answer✔False
Home inspection standards generally require that the inspector test the drinking water quality.
True or false - Answer✔False
A typical exterior inspection includes an examination of the shutters, if they are part of the
structure. True or false - Answer✔False

Home inspectors must inspect readily accessible systems. True or false - Answer✔True
An example of a latent defect is a cracked sewer drain under the foundation. True or false -
Answer✔True
What is the minimum allowed slope of graded soil next to a building's foundation, according to
the International Residential Code (IRC)? - Answer✔¥ 6"/10'

Which of the following is not a solid fuel heating device? - Answer✔Electrical heater
Every basement and sleeping room is required to have an easily operable emergency escape
window. How large must this window be? - Answer✔At least 5.7 sq. ft
The roofing material on a house or other building is considered a part of the roof drainage
system. True or false - Answer✔False
You are inspecting a residential property. You have to observe and/or test all of the readily
accessible components of each system. Determine which of the following is not considered to
be a readily accessible component of a room. - Answer✔Nails or screws in the floor


2
$11.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TheStar Florida State University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
610
Miembro desde
2 año
Número de seguidores
178
Documentos
24049
Última venta
23 horas hace
Stuvia Prodigy

Tested, Verified and Updated Study Materials with 100% Guaranteed Success.

3.8

121 reseñas

5
58
4
21
3
21
2
4
1
17

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes