100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

EPA 608 Type 3 Exam Questions Fully Solved Latest Update 2025 Already Passed

Puntuación
-
Vendido
-
Páginas
4
Grado
A+
Subido en
01-02-2025
Escrito en
2024/2025

EPA 608 Type 3 Exam Questions Fully Solved Latest Update 2025 Already Passed Type 3 - Answers Technicians maintaining, servicing, repairing or disposing of low-pressure appliances must be certified as a universal technician or a _______ ___. enter - Answers Because a low-pressure system operates below atmospheric pressure (in a vacuum), leaks in the gaskets or fittings will cause air and moisture to ______ the system. heater - Answers The most efficient method of leak checking a charged, low-pressure refrigeration unit is to pressurize the system by the use of controlled hot water or ______ blankets. nitrogen - Answers When unable to heat a low-pressure system for leak-checking, use ______ to increase pressure. 10 - Answers When pressurizing a low-pressure system with nitrogen, do not exceed _____ psig. rupture - Answers Exceeding 10 psig when pressurizing a low-pressure system, can cause the _____ disc to fail. removed - Answers When leak testing a water box, be certain the water has been ______ before placing the leak detector probe through the drain valve. hydrostatic - Answers When leak-testing a tube, use a _______ tube test kit. seal - Answers Systems with open drive compressors are prone to leaks at the shaft _____. hot - Answers For the purpose of opening the system for a non-major repair, controlled ______ water can be used to pressurize a system. high pressure - Answers A recovery unit's _____ _____ cut-out is set for 10 psig when evacuating the refrigerant from a low-pressure chiller. 15 - Answers A low-pressure chiller and a rupture disc on a low-pressure recovery vessel relieves at _____ psig. liquid vapor - Answers Refrigerant recovery from a system using R-11 or R-123 starts with ______ removal and is followed by _____ recovery. vapor - Answers A substantial amount of _____ will remain in the appliance after all liquid is removed. 100 - Answers An average 350 ton R-11 chiller at 0 psig still contains _____ lbs. of vapor after all the liquid has been removed. circulated - Answers Water must be ______ through the tubes when evacuating refrigerant in order to prevent freezing the water. condenser - Answers Most low-pressure recovery machines utilize a water-cooled ______ that is connected to the municipal water supply. on - Answers When recovering refrigerant, the system water pumps, the recovery compressor, and the recovery condenser water should all be ______. drained - Answers If a chiller is suspected of tube leaks, the water sides of the evaporator and condenser should be ______ prior to recovering the refrigerant. 2.5 - Answers The ASHRAE Guideline 3-1996 states that if the pressure in a system rises from 1 mm Hg to a level above ____ mm Hg during vacuum testing, the system should be leak checked. 130 - Answers A temperature of _____ F should be attained when removing oil from a low-pressure system. oil - Answers Less refrigerant is contained in the _____ at the higher temperature of 130 degrees

Mostrar más Leer menos
Institución
EPA 608 Type 3
Grado
EPA 608 Type 3








Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
EPA 608 Type 3
Grado
EPA 608 Type 3

Información del documento

Subido en
1 de febrero de 2025
Número de páginas
4
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

EPA 608 Type 3 Exam Questions Fully Solved Latest Update 2025 Already Passed

Type 3 - Answers Technicians maintaining, servicing, repairing or disposing of low-pressure appliances
must be certified as a universal technician or a _______ ___.

enter - Answers Because a low-pressure system operates below atmospheric pressure (in a vacuum),
leaks in the gaskets or fittings will cause air and moisture to ______ the system.

heater - Answers The most efficient method of leak checking a charged, low-pressure refrigeration unit
is to pressurize the system by the use of controlled hot water or ______ blankets.

nitrogen - Answers When unable to heat a low-pressure system for leak-checking, use ______ to
increase pressure.

10 - Answers When pressurizing a low-pressure system with nitrogen, do not exceed _____ psig.

rupture - Answers Exceeding 10 psig when pressurizing a low-pressure system, can cause the _____ disc
to fail.

removed - Answers When leak testing a water box, be certain the water has been ______ before placing
the leak detector probe through the drain valve.

hydrostatic - Answers When leak-testing a tube, use a _______ tube test kit.

seal - Answers Systems with open drive compressors are prone to leaks at the shaft _____.

hot - Answers For the purpose of opening the system for a non-major repair, controlled ______ water
can be used to pressurize a system.

high pressure - Answers A recovery unit's _____ _____ cut-out is set for 10 psig when evacuating the
refrigerant from a low-pressure chiller.

15 - Answers A low-pressure chiller and a rupture disc on a low-pressure recovery vessel relieves at
_____ psig.

liquid vapor - Answers Refrigerant recovery from a system using R-11 or R-123 starts with ______
removal and is followed by _____ recovery.

vapor - Answers A substantial amount of _____ will remain in the appliance after all liquid is removed.

100 - Answers An average 350 ton R-11 chiller at 0 psig still contains _____ lbs. of vapor after all the
liquid has been removed.

circulated - Answers Water must be ______ through the tubes when evacuating refrigerant in order to
prevent freezing the water.

condenser - Answers Most low-pressure recovery machines utilize a water-cooled ______ that is
connected to the municipal water supply.
$9.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TutorJosh Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
332
Miembro desde
1 año
Número de seguidores
16
Documentos
28211
Última venta
1 día hace
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.6

53 reseñas

5
18
4
14
3
12
2
0
1
9

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes