100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

Load calculation Feeders and services Level 4 Module 1 exam 2025 with 100% correct answers

Puntuación
-
Vendido
-
Páginas
4
Grado
A+
Subido en
29-01-2025
Escrito en
2024/2025

What is the demand factor allowed by the NEC® for calculating the neutral conductor size for electric range load? - correct answer️️70% Using the VA/linear foot method, the total VA that must be used in a service calculation for a 50' show window is - correct answer️️12,500VA Before it is considered a continuous load, a load must operate for at least how many hours without interruption? - correct answer️️3 Which of the following factors does not affect conductor ampacity adjustments? - correct answer️️Number of phase If a continuous connected load totals 120A, what is the minimum current-carrying capacity required for the feeder? - correct answer️️150A What is the load center length for a tapped feeder with loads of 120A at 50', 110A at 60', 75A at 90', and 70A at 150'? - correct answer️️79.60 Which of the following lighting loads would be used in a residence that is 1,650 sq ft? - correct answer️️4,950VA What is the load for 40 non-dwelling unit receptacles? (Assume that the load is not continuous.) - correct answer️️7,200VA The minimum service rating for a residential service is - correct answer️️100A Residential small appliance circuit must be rated at - correct answer️️1,500VA Use of the 100' tap rule is limited to installation in high-bay manufacturing buildings with wall heignt over - correct answer️️35 feet Which part of a residential lighting and small appliance load must be rated at 35% for service calculations? - correct answer️️The next 177,000VA If a store lighting load is 14,000VA (continuous), which of the following must be used for the circuit calculation? - correct answer️️17,500VA In most cases, feeder conductor size is adjusted when - correct answer️️there are more than three current-carrying conductors in the raceway When calculating the service requirement for a particular building, the step is to - correct answer️️determine the floor area of the building What is the feeder ampacity for a three-phase, 120/208V subpanel with a connected load of 84,563VA? - correct answer️️235A Which part of a residential lighting and small appliance load must be rated at 35% for servives - correct answer️️ An optional method for determining feeder to schools is covered in - correct answer️️NEC® Section 220.86 Refer to the figure above. What is the total load of a feeder serving four 230V motors rated 5hp, 15hp, 20hp, and 40hp? - correct answer️️241.2 Refer to the figure above. Calculate the minimum ampacity for a feeder serving the following 460V motor: 10hp, 20hp, and 30hp. - correct answer️️91A Refer to the figure above. What is the total load a feeder serving four 2hp motors, three 5hp motors, one 15hp motor, and one 25 hp motor? All motors are 208V. - correct answer️️219.8 A NEC Section ——————-permits an alternative method for calculating loads in multi-family dwelling. - correct answer️️220.84 The smallest size locking and grounding type receptacle that may be used to provide shore power for boats is - correct answer️️30A

Mostrar más Leer menos
Institución
Load Calculation Feeders And Services Level 4
Grado
Load calculation Feeders and services Level 4








Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Load calculation Feeders and services Level 4
Grado
Load calculation Feeders and services Level 4

Información del documento

Subido en
29 de enero de 2025
Número de páginas
4
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

STUDYSAGE

Load calculation Feeders and
services Level 4 Module 1 exam
2025 with 100% correct answers
What is the demand factor allowed by the NEC® for calculating the neutral
conductor size for electric range load? - correct answer✔️✔️70%


Using the VA/linear foot method, the total VA that must be used in a service
calculation for a 50' show window is - correct answer✔️✔️12,500VA


Before it is considered a continuous load, a load must operate for at least how
many hours without interruption? - correct answer✔️✔️3


Which of the following factors does not affect conductor ampacity adjustments?
- correct answer✔️✔️Number of phase


If a continuous connected load totals 120A, what is the minimum current-
carrying capacity required for the feeder? - correct answer✔️✔️150A


What is the load center length for a tapped feeder with loads of 120A at 50',
110A at 60', 75A at 90', and 70A at 150'? - correct answer✔️✔️79.60


Which of the following lighting loads would be used in a residence that is 1,650
sq ft? - correct answer✔️✔️4,950VA


What is the load for 40 non-dwelling unit receptacles? (Assume that the load is
not continuous.) - correct answer✔️✔️7,200VA


The minimum service rating for a residential service is - correct
answer✔️✔️100A
1
$11.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
STUDYSAGE

Conoce al vendedor

Seller avatar
STUDYSAGE Yale University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
3
Miembro desde
1 año
Número de seguidores
0
Documentos
1049
Última venta
6 meses hace
SELLING NOTES ONLINE,,GET ALL YOUR STUDY MATERIALS,QUALITY DOCUMENTS FOR BETTER RESULTS

Welcome to my online store, where I offer a variety of high-quality study documents designed to help students excel in their studies. Whether you need notes, summaries, or exam preparation materials, you'll find resources tailored to different subjects and learning styles. My goal is to support your academic journey by providing accessible and effective study aids." offer a variety of high-quality study documents designed to help students excel in their studies. Whether you need notes, summaries, or exam preparation materials, you'll find resources tailored to different subjects and learning styles. My goal is to support your academic journey by providing accessible and effective study aids."

Lee mas Leer menos
0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes