100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

MASS PLUMBING CODE QUESTIONS AND ANSWERS

Puntuación
-
Vendido
-
Páginas
5
Grado
A+
Subido en
26-01-2025
Escrito en
2024/2025

MASS PLUMBING CODE QUESTIONS AND ANSWERS

Institución
MASS PLUMBING CODE
Grado
MASS PLUMBING CODE









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
MASS PLUMBING CODE
Grado
MASS PLUMBING CODE

Información del documento

Subido en
26 de enero de 2025
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

MASS PLUMBING CODE QUESTIONS AND ANSWERS
How many foot of head do you need for a test on the sanitary drainage system -
Answers- 10'

The min spacing for hangers on horizontal 1" copper - Answers- 6'

No vent shall be installed within _______ of the trap weir - Answers- 2 pipe diameters

When sheet copper is used in plumbing it shall have a min thickness of - Answers- 12
oz per sq ft

The storage time of a sump shall not exceed - Answers- 12 hours

Min drain size on residential laundry - Answers- 1 1/2

Duplex pumps are required on more than ______ water closets - Answers- 5

The min spacing for hangers on horizontal pex is - Answers- 32"

Max distance of 2" trap from vent - Answers- 6'

Max distance from trap to vent 1 1/2 - Answers- 5'

A waste pipe that discharges through and air gap into a properly trapped and vented
fixture is called - Answers- Inderect waste pipe

Min spacing on horizontal 2" copper is - Answers- 10'

Max flow from a shower head - Answers- 2.5 gpm

Min trap seal - Answers- 2"

Trap size of a tub with overhead shower - Answers- 1 1/2

The min clearance for access to a 3" or larger clean out is - Answers- 18"

How many fixture units can a 2" trap hold - Answers- 3

1 1/2 pipe is how many fixture units - Answers- 2

Clean out plugs can be made of - Answers- Brass or plastic

Copper tubing with smallest inside diameter - Answers- Type k

Max drainage fixture units on a 3" soil stack - Answers- 48

, A flexible connector for gas appliances cannot be used for pressure exceeding -
Answers- .5 psi

The vertical distance between a fixture outlet and trap weir shall not exceed - Answers-
24"

Test done with air on sanitary drainage system shall be how many psi - Answers- 5

The min clearance on clean outs 2" or smaller is - Answers- 12"

The min size floor drain is - Answers- 2"

When battery venting laboratory sinks, each relief vent may serve from one to
________ vents - Answers- Five

The min height of a vacuum brackets above he flood lever rim of a fixture - Answers- 6"

The max distance between clean outs on 4" or smaller is - Answers- 50'

Relief vents are required on sanitary stacks of more than how many floors - Answers-
10

stainless steel tubing grade H or SL shall be marked what color - Answers- Blue

Inspection of neutralizing sumo shall be done - Answers- Monthly

Min size drain for residential Food waste grinder is - Answers- 1 1/2

When building drainage is installed in the same trench as the water service what joints
are allowed for the drainage system - Answers- Lead and oakrum

All pvc pipe passing through concrete walls and floors shall have a sleeve having an
annular spade of - Answers- 1"

The min height for a standpipe for a laundry - Answers- 30"

The max distance to run a hot eater line be for a recirculation line is needed - Answers-
100'

A inspector shall make an inspection within how many working days after being notified
- Answers- 2 working days

When battery venting laboratory sinks the min size relief vent is - Answers- 2"

The color marking for potable water is - Answers- Green
$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
GEEKA YALA UNIVERSITY
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
2009
Miembro desde
3 año
Número de seguidores
1447
Documentos
48320
Última venta
1 día hace

3.8

345 reseñas

5
172
4
61
3
44
2
16
1
52

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes