Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 6 páginas
Examen

AGR 324 exam 1 || (Needed to Pass) Confirmed A+.

Document preview thumbnail
Vista previa 2 fuera de 6 páginas

what are the 4 questions we ask in lab correct answers 1. Is it too light or too dark? 2. Is it over or under penetrated? 3. Are there any artifacts? 4. Is the positioning okay? what question relates to mAs correct answers is it too light or too dark what question relates to kVp correct answers is it over or underpenetrated do we want a larger number or smaller number for seconds correct answers smallest 1/60 or 1/20 what should our machine equal (mA x sec) correct answers 5 what is indirect proportionality correct answers as one quantity gets larger the other gets smaller what is direct proportionality correct answers if the image gets darker when I increase the mA (the first quantity is a multiple of the second) does it matter if the animal is positioned properly before measuring with the calipers correct answers yes does our stationary x-ray machine use more or less volts than a hair dryer correct answers more the distance between what is called the wavelength correct answers crest or troughs the electrons are boiled off of the ___ and travel to the ___ correct answers cathode, anode who discovered x-rays correct answers Wilhelm Roentgen (1895) do x-rays travel in a straight or curved line correct answers straight what is electrification correct answers electron charges being added to or subtracted from an object what are 3 ways objects can be electrified correct answers contact, friction, induction what is Sante's rule and what setting does it tell us correct answers cm x 2 + 40= kVp what is potential difference correct answers the strength of the electron flow from one end of the wire to the other (volt) which wire has little resistance correct answers large wire if you increase mA will the image get lighter or darker correct answers darker

Vista previa del contenido

AGR 324 exam 1 || (Needed to Pass) Confirmed A+.
what are the 4 questions we ask in lab correct answers 1. Is it too light or too dark?
2. Is it over or under penetrated?
3. Are there any artifacts?
4. Is the positioning okay?

what question relates to mAs correct answers is it too light or too dark

what question relates to kVp correct answers is it over or underpenetrated

do we want a larger number or smaller number for seconds correct answers smallest 1/60 or 1/20

what should our machine equal (mA x sec) correct answers 5

what is indirect proportionality correct answers as one quantity gets larger the other gets smaller

what is direct proportionality correct answers if the image gets darker when I increase the mA
(the first quantity is a multiple of the second)

does it matter if the animal is positioned properly before measuring with the calipers correct
answers yes

does our stationary x-ray machine use more or less volts than a hair dryer correct answers more

the distance between what is called the wavelength correct answers crest or troughs

the electrons are boiled off of the ___ and travel to the ___ correct answers cathode, anode

who discovered x-rays correct answers Wilhelm Roentgen (1895)

do x-rays travel in a straight or curved line correct answers straight

what is electrification correct answers electron charges being added to or subtracted from an
object

what are 3 ways objects can be electrified correct answers contact, friction, induction

what is Sante's rule and what setting does it tell us correct answers cm x 2 + 40= kVp

what is potential difference correct answers the strength of the electron flow from one end of the
wire to the other (volt)

which wire has little resistance correct answers large wire

if you increase mA will the image get lighter or darker correct answers darker

, What mA and kVp setting does a typical x-ray generator supply (max values) correct answers
300 mA, 125 kVp

after the electrical box, power is then carried in what pathway to get to the x-ray tube correct
answers x-ray generator then transformer then the x-ray tube

what does the line voltage compensator do correct answers stabilizes the voltage that's delivered
to the generator

what was the initial problem with the alternating current sent at 100 cycles/sec correct answers it
produced a very slight flicker as the current switched between negative & positive

what 2 transformers increase incoming voltage correct answers autotransformer, high-tension

which transformer decreases voltage correct answers filament

what is single phase full wave rectified circuit correct answers uses all available currents,
occasionally the rectifiers fail and the current it only 1/2 rectified (50% too light)

what is the three phase circuit correct answers has 2 more waveforms added to prevent a ripple,
but is very expensive and high powered

what is the high frequency circuit correct answers many phases overlap to prevent a ripple, is
less expensive and allows for more x-rays

which circuit is better to use correct answers high frequency

do equine portable units have a higher or lower mA and kVp than a stationary unit correct
answers lower (30 mA & 80 kVp)

is heat or x-rays produced more in the x-ray tube correct answers heat (99%)

what helps with heat dissipation correct answers rotating anode and wire types

what does a stationary anode contain to help with heat dissipation correct answers made of
copper and tungsten wire

what is the line focus principle correct answers electrons are directed to the anode, converted to
x-radiation, directed down to patient in a smaller central ray due to the angle of the anode

what is the focal spot bloom correct answers focal spot size expands

what is the anode heel effect correct answers radiation/intensity is greater on the cathode end, the
thicker portion of the patient should be on the cathode end

Información del documento

Subido en
24 de enero de 2025
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$11.19

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
SirAnton
3.7
(118)
Vendido
790
Seguidores
438
Artículos
39806
Última venta
19 horas hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes