Gates Exam/ 49 Q&A, 2025.
For Class A loading, no piece of freight can be more _______ of rated load. - Answer: 25%
Loads for Class A are transported on an off of the platform _______ - Answer: Manually
Trucks or automobiles on Class B freight platforms cannot exceed _______ of rated load. -
Answer: 75 %
The load for Class B items must be equally divided no less than _______ feet apart. - Answer: 5
Class C, C1 is designed to carry loads that include the _______ - Answer: Industrial Truck
Class C, C3 freight cars must be lockable at the floor during loading and unloading. - Answer:
True
Page 1 of 6
, The _______ must be capable of supporting the loads to be carried during loading and
unloading. - Answer: Sill
Once the "king" rail is clamped in place, proper opening width between it and the opposite rail
can be determined with a _______. - Answer: Distance gauge
For the installation of guide rails below the sill level, in a water-resistant pit, manufacturers
provide _______ - Answer: Spreaders
When securing the bolts to the guide rails , always locate the bolts _______ of the rail mounting
slot. - Answer: At the top
Door motor and sheaves should be in place before the door panels are put in place. - Answer:
True
When hoisting lower door panels with truckable sills, wire rope is wrapped around the _______.
- Answer: Trucking sill extension
When lower panels are installed, they should be set on the sill stops and the top edge of the
panel adjusted to _______ the landing sill level. - Answer: Level with
If lower panels are installed with guide stops, they should be set on the guide stops and the
panel upper edge should be adjusted to _______ the landing sill level. - Answer: 1/8 inch below
When balancing both vertically bi-parting freight doors, they should be set with a slight
tendency to drift _______ - Answer: Open