Fresenius Virtual Learning PCT New Hire Exam Review Questions and Answers 100% Pass How long does the RO have to be running before we perform any water testing? - 15 minutes What does IFU stand for? - instructions for use ***Instructions written by the manufacturer that are approved by the FDA. How long does the sample valve need to be flushed after the RO has been running for 15 minutes before a sample is collected? - 2 minutes What is the frequency for testing the Total Chlorine? - Before the first patient of the day is put on AND every 4 hours after that. Name the test trip used to test Total Chlorine: - RPC Ultra-Low Total Chlorine Strips What does TDS stand for? - Total Dissolved Solids The RPC Ultra-Low Total Chlorine Strips are used to test the functionality of what tanks in the water room? - GAC (Granular Activated Carbon) tanks Which tanks in the water room are responsible for removing Total Chlorine? - GAC tanks (Granular Activated Carbon tanks) 2 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE What is the TDS meter used to measure? - The TDS meter measures the functionality of the RO and how well it is removing those particles we do not want to expose the patient to during treatment. What 3 things does the pHoenix Meter, pHoenix XL Meter and Myron L-D6 Meter test dialysate for? - 1. conductivity 2. pH 3. temperature What strips are used to measure water hardness? - SteriChek Water Hardness Reagent Strips What do the SteriChek Water Hardness Reagent Strips measure for? - water hardness SteriChek Water Hardness Reagent Strips measure water hardness. What two minerals do these strips specifically measure that are responsible for hard water? - calcium and magnesium The water system uses a water softener to remove calcium and magnesium. When calcium and magnesium are removed, what is added to the water in their place? - sodium (Na+) How often is water hardness tested? - 2 times a day When is water hardness (caused by calcium and magnesium) tested? - Before the first patient and at the end of the day When the water is tested for water hardness (caused by calcium and magnesium) before the first patient is put on AND at the end of the day (twice daily), what is the acceptable amount of these minerals found with the SteriChek Water Hardness Reagent Strips? - < 20 ppm (pa

Mostrar más Leer menos
Institución
Fresenius
Grado
Fresenius










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Fresenius
Grado
Fresenius

Información del documento

Subido en
22 de diciembre de 2024
Número de páginas
23
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

1|Page




Fresenius Virtual Learning PCT New
Hire Exam Review Questions and
Answers 100% Pass

How long does the RO have to be running before we perform any water testing? - ✔✔15 minutes


What does IFU stand for? - ✔✔instructions for use




***Instructions written by the manufacturer that are approved by the FDA.


How long does the sample valve need to be flushed after the RO has been running for 15 minutes before

a sample is collected? - ✔✔2 minutes


What is the frequency for testing the Total Chlorine? - ✔✔Before the first patient of the day is put on

AND every 4 hours after that.


Name the test trip used to test Total Chlorine: - ✔✔RPC Ultra-Low Total Chlorine Strips


What does TDS stand for? - ✔✔Total Dissolved Solids


The RPC Ultra-Low Total Chlorine Strips are used to test the functionality of what tanks in the water

room? - ✔✔GAC (Granular Activated Carbon) tanks


Which tanks in the water room are responsible for removing Total Chlorine? - ✔✔GAC tanks (Granular

Activated Carbon tanks)




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

,2|Page


What is the TDS meter used to measure? - ✔✔The TDS meter measures the functionality of the RO and

how well it is removing those particles we do not want to expose the patient to during treatment.


What 3 things does the pHoenix Meter, pHoenix XL Meter and Myron L-D6 Meter test dialysate for? -

✔✔1. conductivity


2. pH


3. temperature


What strips are used to measure water hardness? - ✔✔SteriChek Water Hardness Reagent Strips


What do the SteriChek Water Hardness Reagent Strips measure for? - ✔✔water hardness


SteriChek Water Hardness Reagent Strips measure water hardness. What two minerals do these strips

specifically measure that are responsible for hard water? - ✔✔calcium and magnesium


The water system uses a water softener to remove calcium and magnesium. When calcium and

magnesium are removed, what is added to the water in their place? - ✔✔sodium (Na+)


How often is water hardness tested? - ✔✔2 times a day


When is water hardness (caused by calcium and magnesium) tested? - ✔✔Before the first patient and at

the end of the day


When the water is tested for water hardness (caused by calcium and magnesium) before the first patient

is put on AND at the end of the day (twice daily), what is the acceptable amount of these minerals found

with the SteriChek Water Hardness Reagent Strips? - ✔✔< 20 ppm (parts per million)


What test strips are used to measure residual chlorine? - ✔✔Water Check RC Strips


When do we use the Water Check RC Strips during the week? - ✔✔after bleach day and before the first

patient is put on




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

, 3|Page


If you find a vile of test strips that are not dated, can we use them for testing purposes? - ✔✔no


What is the minimum number for GAC (carbon tanks) your clinic can have? - ✔✔2




***Your clinic may have 4 GAC tanks


In a clinic with 2 GAC tanks, the first tank is called the ______ tank, and the second tank is called the

______ tank. - ✔✔worker, polisher


The worker tank is also called the _______ tank. - ✔✔primary


The polisher tank is also called the _______ tank. - ✔✔secondary


When the opener at your clinic runs the RO for 15 minutes then waits the required 2 minutes for the

sample valve to run before collecting a sample, after which GAC tank is the valve located for testing Total

Chlorine? - ✔✔worker tank (primary tank)




***We are checking the functionality of the worker tank


How many employees have to watch the sample for the Total Chlorine test be obtained? - ✔✔2 (opener

plus a second employee)




***One employee MUST be a RN


Two employees (the opener plus a second employee) must be present when the sample for the Total

Chlorine test is obtained. How many employees total must be present when the test strip is gently moved

back and forth in the sample cup? - ✔✔2




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE
$12.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
KatelynWhitman West Virginia University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1094
Miembro desde
2 año
Número de seguidores
482
Documentos
33057
Última venta
1 día hace
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online&amp; Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&amp;A MATERIALS.

3.6

238 reseñas

5
95
4
38
3
54
2
20
1
31

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes