Terms in this set (127) A journeyman plumber and an apprentice, who are employed by a master plumber, are installing the DWV- system and water distribution system in a 2-½ story single family dwelling. QUESTION: What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: A trap that serves a single shower stall that is equipped with a hand shower, a rain head, and a standard shower head shall be no less than ________ in minimum diameter A) 1-½" B) 2" C) 2-½" D) 3" 2 inches 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… A journeyman plumber and apprentice are installing 3-inch floor drains in an open- parking-garage that is subject to freezing temperatures. QUESTION: What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: The installation of traps at the floor drain locations which are found susceptible to freezing temperatures may be __________. A)Increased to 4-inch B) Eliminated C) Wrapped with freeze protection cable D) Insulated eliminated 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… A journeyman plumber and apprentice are installing lab sinks with faucets that are connected to an acid waste system for- (special hazardous waste) in a medical lab. What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: Vacuum breakers shall be installed with the critical level at least _____-inches above the flood level rim of the fixture they serve and on the discharge side of the last control valve to the fixture. A) 12 B) 6 C) 18 D) 3 6 inches 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: No plumbing permit shall be issued for cross connection installations that require ______________ until the application for a permit is accompanied by a letter of approval from the Massachusetts Department of Environmental Protection or its designee. A) RPBP B) A "critical level" height C) Atmospheric vacuum breakers D) Water recycling systems reduced pressure backflow preventer (RPBP) 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… : What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: The waste discharge from safe waste pans serving water heaters or hot water storage tanks where there is _______ below and shall be piped indirectly to a properly trapped and vented fixture. A) People B) Occupancy C) Floors D) Plumbing connections occupancy 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… GIVEN: A journeyman plumber and an apprentice, (who are employed by a master plumber), are installing the sanitary DWV and water distribution system in a five-story residential condominium complex. QUESTION: What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: CPVC- (Chlorinated Polyvinyl Chloride) pipe and fittings may be used provided that none of this material is located within ____-inches of any connection to a hot water tank as defined in MGL. c. 142, § 17 A) 12 B) 18 C) 20 D) 24 E) 30 24 inches 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… : A journeyman plumber and apprentice are roughing-in multiple fixtures in a new fitness center. The facility will include a juice bar, temporary daycare room, men's and women's toilet facilities and men's and women's locker rooms. QUESTION: What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: A ________-vent is a branch vent that serves two or more floor-outlet fixtures that are battery wasted. The vent extends from the top of the horizontal soil and/or waste branch in front of the last fixture waste and connects to a vent stack or stack vent that is adjacent to the down-stream end of the horizontal branch. A) Side B) Loop C) Relief D) Circuit loop 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… MATCH: Elevated pressure Flow designation Ten P.S.I.G. or less Less than 2-P.S.I A) 3 P.S.I.G. or ten times B) Inlet pressure C) E.H.D. D) Prof. Engineer elevated pressure- d flow designation-c Ten P.S.I.G. or less-a Less than 2-P.S.I-b N: A journeyman plumber is installing category-I gas appliances and equipment in the basement of a building. A 120,000 BTU/hr. boiler and 40,000 BTU/hr. water heater are being installed. QUESTION: What answer below shall be considered most correct to complete the following "Gas code knowledge" related statement: The boiler requires a minimum of _____-cu. ft. of air to support proper combustion A) 2,400 cu. ft. B) 120 sq. in. C) 3,200 sq. ft. D) 800 cu. ft. 2,400 cu. ft. 120,000/50 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… ) QUESTION: What answer below shall be considered most correct to complete the following "Gas code knowledge" related statement: The code would require the gas vent penetrating the roof in-[FIGURE-TP-B- Q1-1A: GAS VENT SIZING] as identified at point-[A] to be not less than ______ above any portion of a building within 10-feet horizontally. A) 24" B) 3-feet C) 30- inches D) Forty-two- inches 24

Vista previa del contenido

12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM 2024-2025 ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G…




PLUMBING LEVEL 3 EXAM 2024-2025 ACTUAL
EXAM 60 QUESTIONS AND CORRECT
DETAILED ANSWERS |ALREADY GRADED A


Practice questions for this set


Learn 1 /7 Study with Learn




Reforming pocket



Choose matching term



A journeyman plumber/gas-fitter is connecting schedule-40 steel gas piping to a
natural gas fired roof-top heating and air conditioning unit that has been place
on the roof of a 1-story commercial building by the HVAC mechanical contractor.
QUESTION: What answer below shall be considered most correct to complete
1 the following "Gas code knowledge" related statement: The journeyman
plumber/gas-fitter is responsible to determine that this gas equipment has been
placed or set on its curb at least ______ from the roof's edge.

A) 8-feet B) 6-feet C) 5-feet D) 4-feet




https://quizlet.com/985457417/plumbing-level-3-exam-2024-2025-actual-exam-60-questions-and-correct-detailed-answers-already-graded-a-flash-car… 1/93

,12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM 2024-2025 ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G…

) GIVEN: A journeyman and apprentice plumber are completing the installation
of a vacuum powered sanitary drainage systems. The system is in a supermarket
serving drainage connections for vegetable and produce display coolers.
QUESTION: What answer below shall be considered most correct to complete
the following "Plumbing code knowledge" related statement: The image
2 presented in-[FIGURE-TP-B-Q1-4B: VACUUM DRAINAGE SYSTEM
KNOWLEDGE] IS known as a _______ and represents a method of assembling pipe
and fittings in a manner to re-establish a waste slug.

A) Accumulator B) Vacuum interface C) Collector D) Reforming pocket E) No
answer is correct




: A journeyman plumber has installed a 3-inch cast iron horizontal branch drain in
the basement of a building. The overall length of the branch is 42-feet.
QUESTION: What answer below shall be considered most nearly correct to
complete the following "Plumbing math knowledge" related statement: When
3
filled with water for the purpose of a rough underground plumbing inspection
the capacity in gallons of the branch will be approximately ________.

A) 10 to 12 B) 12 to 14 C) 15 to 17 D) 20 to 22




Ice machines =
Residential dishwasher =
Drips or drainage outlets =
Standpipe-(clothes washer) =
4
Safe waste pans =
Sterile materials=

air gap, air break either



Don't know?




https://quizlet.com/985457417/plumbing-level-3-exam-2024-2025-actual-exam-60-questions-and-correct-detailed-answers-already-graded-a-flash-car… 2/93

,12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM 2024-2025 ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G…

Terms in this set (127)

A journeyman plumber 2 inches
and an apprentice, who
are employed by a
master plumber, are
installing the DWV-
system and water
distribution system in a
2-½ story single family
dwelling. QUESTION:
What answer below
shall be considered
most correct to
complete the following
"Plumbing code
knowledge" related
statement: A trap that
serves a single shower
stall that is equipped
with a hand shower, a
rain head, and a
standard shower head
shall be no less than
________ in minimum
diameter


A) 1-½" B) 2" C) 2-½" D)
3"




https://quizlet.com/985457417/plumbing-level-3-exam-2024-2025-actual-exam-60-questions-and-correct-detailed-answers-already-graded-a-flash-car… 3/93

, 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM 2024-2025 ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G…

A journeyman plumber eliminated
and apprentice are
installing 3-inch floor
drains in an open-
parking-garage that is
subject to freezing
temperatures.
QUESTION: What
answer below shall be
considered most
correct to complete the
following "Plumbing
code knowledge"
related statement: The
installation of traps at
the floor drain locations
which are found
susceptible to freezing
temperatures may be
__________.


A)Increased to 4-inch B)
Eliminated C) Wrapped
with freeze protection
cable D) Insulated




https://quizlet.com/985457417/plumbing-level-3-exam-2024-2025-actual-exam-60-questions-and-correct-detailed-answers-already-graded-a-flash-car… 4/93

Información del documento

Subido en
17 de diciembre de 2024
Número de páginas
93
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
OliviaWest
2.7
(23)
Vendido
119
Seguidores
17
Artículos
8395
Última venta
1 mes hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes