Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

PSI Journeyman Online exam with correct answers Graded A+ 2024

Puntuación
-
Vendido
-
Páginas
8
Grado
A+
Subido en
28-11-2024
Escrito en
2024/2025

A fitting is a part of a wiring system that is intended primarily to perform which type of function? correct answers mechanical When the disconnecting means of a transformer is located remotely it must be? correct answers lockable If installed and routed on the outside of a raceway, the length of the equipment bonding jumper shall not exceed how many feet? correct answers 6 feet What is an askarel? correct answers a group of nonflammable synthetic chlorinated hydrocarbons used as electrical insulating media In which locations are the installation of flexible metal conduit permitted? correct answers concealed locations Unlisted nonconductive outside plant optical fiber cables shall not be permitted to be installed in which type of raceways? correct answers flexible metal conduit. Where the negative polarity of a dc system does not serve as the connection point for the grounded conductor, which color finish can be used to identify the negative ungrounded conductor? correct answers black Where a feeder supplies continuous loads or any combination of continuous and noncontinuous loads, the minimum feeder conductor size shall have an allowable ampacity not less than the noncontinuous load plus what percentage of the continuous load? correct answers 125% Where an ac system is grounded at any point, the grounded conductors shall be routed with the ungrounded conductors to each service disconnecting means and shall be connected to each disconnecting means grounded conductors terminal or bus for an ac system operating at how many volts? correct answers 1,000 volts or less What is the maximum spacing for supports of 10 AWG copper conductors located in a vertical raceway? correct answers 100 feet What is the maximum overcurrent protection for a 10 AWG copper conductor? correct answers 30 amperes A circuit breaker does not have an interrupter rating shown on it. What is the interrupter rating of this circuit breaker? correct answers 5,000 amperes

Mostrar más Leer menos
Institución
PSI Journeyman Online Practice
Grado
PSI Journeyman Online Practice

Vista previa del contenido

PSI Journeyman Online Practice

A fitting is a part of a wiring system that is intended primarily to perform
which typecorrect
function? of answers
mechanical
When the disconnecting means of a transformer is located remotely it must
be? correct
answers
lockable
If installed and routed on the outside of a raceway, the length of the
equipment
jumper shallbonding
not exceed how many feet? correct
answers 6 feet
What is an askarel? correct answers a group of nonflammable synthetic
chlorinated
hydrocarbons used as electrical insulating
media
In which locations are the installation of flexible metal conduit
permitted?
answers correct
concealed
locations
Unlisted nonconductive outside plant optical fiber cables shall not be
permittedintowhich
installed be type of raceways? correct answers flexible
metal conduit.
Where the negative polarity of a dc system does not serve as the
connection
the grounded point for
conductor, which color finish can be used to identify
the negative conductor? correct answers
ungrounded
black
Where a feeder supplies continuous loads or any combination of
continuous andloads, the minimum feeder conductor size shall have an
noncontinuous
allowable
ampacity not less than the noncontinuous load plus what percentage of the
load? correct answers
continuous
125%
Where an ac system is grounded at any point, the grounded conductors shall
be routed
with the ungrounded conductors to each service disconnecting means
and shall be
connected to each disconnecting means grounded conductors terminal or
bus for an ac
What is the maximum spacing for supports of 10 AWG copper conductors
system operating at how many volts? correct answers 1,000
located
volts or in
vertical a
raceway?
less correct answers
100 feet
What is the maximum overcurrent protection for a 10 AWG copper
conductor?
answers 30 correct
amperes
A circuit breaker does not have an interrupter rating shown on it. What is the
interrupter
rating of this circuit breaker? correct answers 5,000
amperes

, Dry-type transformers rated over which voltage shall be installed in a
vault? correct
answers 35,000
volts
A panelboard for a mobile home shall be rated not less than which of the
following?
correct answers 50
amperes
An electrical appliance is rated at 1,500 watts, and is connected to 120
volts.
the What is associated with this appliance? correct answers
resistance
9.6 ohms
High-impedance grounded neutral systems in which a grounding
impedance
ground faultlimits theto a low value shall be permitted for which type of
current
system? 3-phase
answers correct ac systems of 480 volts to
1,000 volts
Where the positive polarity of a dc system does not serve as the
connectionconductor,
grounded for the which color finish can be used to identify the positive
ungrounded
conductor? correct answers
red
Information technology equipment shall be permitted to be connected to a
branch
by circuit
a power-supply cord with a maximum length of how many feet? correct
answers 15
fee
t
What is the maximum distance that the emergency controls for an attended
self-service
motor fuel dispensing facility shall be located from the dispensers? correct
answers 100
fee
t
What is the greatest root-mean-square (effective) difference of potential
between
two any of a circuit defined as? correct answers
conductors
voltage
A motor controller disconnecting means shall be permitted to be out of
sight of the
controller for motor circuits over how many volts? correct answers 1,000
volts, nominal
The following measurements are taken on a 3-phase load: power used is
11,250
208 watts,
volts applied, and current is 35 amperes per phase leg. What is the
power
the factor
load? of answers
correct
89%
Alternating-current systems of less than 50 volts shall be grounded where
supplied by if the transformer supply system exceeds which of the
transformers,
following?
answers 150correct
volts to
ground
In a fire alarm system, single conductors shall not be smaller than? correct
answers 18
AWG

What is the maximum voltage drop for any branch circuit, separately
derived system,
operating at 120 volts line-to-line and 60 volts to ground, serving sensitive
electronic
equipment? correct answers
1.5%

Escuela, estudio y materia

Institución
PSI Journeyman Online Practice
Grado
PSI Journeyman Online Practice

Información del documento

Subido en
28 de noviembre de 2024
Número de páginas
8
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$14.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
HopeJewels Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
88
Miembro desde
2 año
Número de seguidores
11
Documentos
8867
Última venta
1 semana hace
macellen education agencies

CHAMBERLAIN EXAM SHOP YOU WANT AN EXAM - I GOT YOU. Why choose us? ☑️ Committed to your SATISFACTION. ☑️ Competitive pricing ☑️ Guaranteed EXCELLENCE! Feel welcome to contact us. BUY DOUBT FREE!!!!

3.6

8 reseñas

5
4
4
0
3
2
2
1
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes