Definitions - UST Exam UPDATED ACTUAL Questions and CORRECT Answers Which agency approves a site-specific variance which allows for an alternative method of construction or monitoring: a.) The Regional Water Quality Board b.) The State Water Resources Control Board c.) The Department of Toxic Substance Control d.) The local agency - CORRECT ANSWER - a.) The Regional Water Quality Board CCR Title 23, Sec 2681(

Mostrar más Leer menos
Institución
Underground Storage Tanks
Grado
Underground Storage Tanks











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Underground Storage Tanks
Grado
Underground Storage Tanks

Información del documento

Subido en
27 de noviembre de 2024
Número de páginas
32
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Definitions - UST Exam UPDATED
ACTUAL Questions and CORRECT
Answers
Which agency approves a site-specific variance which allows for an alternative method of
construction or monitoring:
a.) The Regional Water Quality Board
b.) The State Water Resources Control Board
c.) The Department of Toxic Substance Control

d.) The local agency - CORRECT ANSWER - a.) The Regional Water Quality Board
CCR Title 23, Sec 2681(a)


The regulations to enforce compliance of underground storage tank systems in the state are found
in?
a.) Code of Federal Regulations, 40 CFR Part 281
b.) California Code of Regulations, Title 23, Chapter 16
c.) Code of Federal Regulations, 40 CFR Part 280

d.) California Code of Regulations, Title 23, Chapter 17 - CORRECT ANSWER - b.)
California Code of Regulations; Title 23, Chapter 16


By definition an "underground storage tank system" includes
a.) The tank, all connected piping and dispensers
b.) The tank, all connected piping, ancillary equipment and containment system
c.) Only the tank

d.) Only tanks totally beneath the surface of the ground - CORRECT ANSWER - b.) The
tank, all connected piping, ancillary equipment and containment system


(H&SC, Sec 25281(z))

,The written report submitted to the local agency after an unauthorized release is required to
include the following except:
a.) Description of actions taken to stop the release
b.) Cause of the release
c.) Method of disposal of released product

d.) Date on which the release was discovered - CORRECT ANSWER - b.) Cause of the
release
CCR Title 23, Sec 2652(c)


An unauthorized release which does not escape from secondary containment only requires a
record on the operator's monitoring reports provided:
A. It did not increase the hazard of fire
B. It did not cause any deterioration of the secondary containment
C. It was cleaned up within 8 hours of detection

D. All of the above - CORRECT ANSWER - D. All of the above
H&SC, Sec 25294


The annual monitoring certification may be performed by:
A. A person possessing the appropriate contractors licenses
B. An individual trained and certified by the manufacturer of the monitoring equipment
C. A designated UST operator

D. A person who meets the requirements of both a and b - CORRECT ANSWER - D. A
person who meets the requirements of both a and b
CCR Title 23, Sec 2715(i)


When an automatic tank gauge is utilized for single-walled tank leak detection, it shall generate a
post-test hard copy data report of the following information, except:
a.) Liquid volume
b.) Fuel depth
c.) Outside air temperature

,d.) Time and date of test - CORRECT ANSWER - c.) Outside air temperature
CCR Title 23, Sec 2643(b)(1)


If a UST system is utilizing an overfill alarm, the alarm must be triggered to alert the transfer
operator when the tank is no more than ___________ full
a.) 85%
b.) 95%
c.) 90%

d.) 80% - CORRECT ANSWER - c.) 90%


An automatic tank gauge is utilized for leak detection of the ______________.
a.) Tank
b.) Tank and Piping
c.) Piping

d.) Interstitial space - CORRECT ANSWER - a.) Tank
CCR Title 23, Sec 2643(b)(1)


After completion of enhanced leak detection (ELD) test, the ELD test results must be submitted
to the _________________.
a.) The local agency
b.) The SWRCB
c.) Owner of the UST system

d.) To both the SWRCB and the local agency - CORRECT ANSWER - d.) To both the
SWRCB and the local agency
CCR Title 23, Sec 2644.1(a)(5)


A permit to operate a UST system must have all of the following listed on the permit, EXCEPT:
a.) The state UST identification number(s)
b.) Name of the tank manufacturer and tank capacity

, c.) Permit expiration date

d.) Monitoring requirements - CORRECT ANSWER - b.) Name of the tank manufacturer
and tank capacity
CCR Title 23, Sec 2712(c)


A temporary closure is appropriate for which of the following:
a.) The UST system is empty and will be removed from service indefinitely
b.) The UST system has ceased to store hazardous materials but will be used within the next 12
consecutive months
c.) The UST system is unable to meet compliance requirements and will be removed

d.) The UST system has been red-tagged - CORRECT ANSWER - b.) The UST system
has ceased to store hazardous materials but will be used within the next 12 consecutive months
CCR Title 23, Sec 2671 & 2670


A local agency determines that a UST facility within the last year had compliance issues. Prior to
issuing a new permit or renewal to operate an UST the local agency shall:
a.) Ask the state to assist in a joint inspection
b.) Request the owner/operator to submit a "Return to Compliance" form.
c.) Refer to a District Attorney Investigator

d.) Inspect the facility and determine compliance - CORRECT ANSWER - d.) Inspect the
facility and determine compliance
CCR Title 23, Sec 2712(c)


All the following components require third party certification, except:
a.) Automatic tank gauging systems
b.) Statistical inventory reconciliation methods
c.) Spill Containment lids

d.) Liquid phase out-of-tank products - CORRECT ANSWER - c.) Spill Containment lids
$10.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MGRADES Stanford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1123
Miembro desde
1 año
Número de seguidores
104
Documentos
68962
Última venta
10 horas hace
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

178 reseñas

5
76
4
31
3
47
2
9
1
15

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes