NMTCB PET PRACTICE QUESTIONS #1 WITH ACCURATE ANSWERS

Document preview thumbnail
Vista previa 2 fuera de 13 páginas

NMTCB PET PRACTICE QUESTIONS #1 WITH ACCURATE ANSWERSNMTCB PET PRACTICE QUESTIONS #1 WITH ACCURATE ANSWERSNMTCB PET PRACTICE QUESTIONS #1 WITH ACCURATE ANSWERS Quantitative bias that refers to the underestimation of counts density which differs from what they should be is called: (A) Motion artifact (B) Partial-volume effect (C) Recovery coef fi cient (D) Truncation artifact - ANSWER-(B) Partial-volume effect Truncation artifacts in PET/CT imaging are produced by: (A) Contrast medium (B) Difference in size of FOV between PET and the CT (C) Difference in scanning time between PET and the CT (D) Beds overlapping - ANSWER-(B) Difference in size of FOV between PET and the CT Property of PET detectors that allows them faster timing signals for coincidence detection and to work at high count rates is called: (A) The stopping power (B) Energy resolution (C) The decay constant

Vista previa del contenido

NMTCB PET PRACTICE QUESTIONS #1
WITH ACCURATE ANSWERS

Quantitative bias that refers to the underestimation of counts density which
differs from what they should be is called:
(A) Motion artifact
(B) Partial-volume effect
(C) Recovery coef fi cient
(D) Truncation artifact - ANSWER-(B) Partial-volume effect

Truncation artifacts in PET/CT imaging are produced by:
(A) Contrast medium
(B) Difference in size of FOV between PET and the CT
(C) Difference in scanning time between PET and the CT
(D) Beds overlapping - ANSWER-(B) Difference in size of FOV between PET and the
CT

Property of PET detectors that allows them faster timing signals for coincidence
detection and to work at high count rates is called:
(A) The stopping power
(B) Energy resolution
(C) The decay constant
(D) The light output - ANSWER-(C) The decay constant

The first PET radiopharmaceutical to receive the U.S. Food and Drug
Administration approval in 1989 was:
(A) Rb-82
(B) F-18 Fluoride
(C) F-18 FDG
(D) N-13 ammonia - ANSWER-(A) Rb-82

The dose calibrator quality control procedure performed to assess the device's
ability to measure accurately a range of a low to high activities is called:
(A) Geometry
(B) Accuracy
(C) Linearity
(D) Constancy - ANSWER-(C) Linearity


The earliest disposal of the decay-in-storage waste material is permitted if it
was held for a minimum 10 half-lives and has decayed to less than:
(A) Background level

, (B) Two times background levels
(C) 0.05 mR/h
(D) 0.5 mR/h - ANSWER-(B) Two times background levels

The recommended time interval for PET imaging after biopsy is:
(A) 1 week
(B) 2-4 weeks
(C) 2-6 months
(D) > 6 months - ANSWER-(A) 1 week

The example of the anatomic diagnostic modality employed in the work-up of
the patient with seizures is:
(A) Electroencephalography (EEG)
(B) Positron emission tomography (PET)
(C) Magnetic resonance imaging (MRI)
(D) Single-photon emission computed tomography (SPECT) - ANSWER-(C) Magnetic
resonance imaging (MRI)

The following positron-emitting radionuclides are isotopes of natural elements present in
most biochemical processes EXCEPT:
(A) O-15
(B) F-18
(C) C-11
(D) N-13 - ANSWER-(B) F-18

Two photons arising from the same annihilation event and detected by two
detectors within the coincidence time-window are:
(A) True coincidences
(B) Random events
(C) Scatter coincidences
(D) Single events - ANSWER-(A) True coincidences

Positronium (Ps) is an arrangement of:
(A) Two positrons
(B) Two electrons
(C) An electron and a positron
(D) A positron and a neutrino - ANSWER-(C) An electron and a positron

The combined whole-body effective dose for a clinically diagnostic PET/CT is
typically in the range:
(A) <10 mSv
(B) 10-20 mSv
(C) 20-30 mSv
(D) >30 mSv - ANSWER-(C) 20-30 mSv

The positron has the same mass as an electron and an electric charge of:

Información del documento

Subido en
25 de noviembre de 2024
Número de páginas
13
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
NursingTutor1
3.9
(459)
Vendido
1697
Seguidores
1073
Artículos
18441
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes