Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 14 páginas
Examen

PET/CT MIDTERM| 99 QUESTIONS AND ANSWERS 100% CORRECT

Document preview thumbnail
Vista previa 2 fuera de 14 páginas

PET/CT MIDTERM| 99 QUESTIONS AND ANSWERS 100% CORRECT PET/CT MIDTERM| 99 QUESTIONS AND ANSWERS 100% CORRECT PET/CT MIDTERM| 99 QUESTIONS AND ANSWERS 100% CORRECT Explain the meaning of pitch - ANSWER-The table movement of the patient going through the gantry. The smaller the pitch the longer the scan time and increased patient dose there is. If the pitch is bigger then it can cause gaps and miss sections of the body that are needing to be imaged and also degrades contrast. What is the purpose of windowing (window level and window width) of a set of CT images? - ANSWER-Allowing the certain tissue to be displayed while the other values (HU) that are below and above the set window to be out of range with lower intensity. CT voxel values are given in terms of _______________ , which express the attenuation of a given tissue relative to that of ____________. - ANSWER-Hounsfield units, water The two types of x-rays produced in an x-ray tube are

Vista previa del contenido

PET/CT MIDTERM| 99 QUESTIONS AND
ANSWERS 100% CORRECT
Explain the meaning of pitch - ANSWER-The table movement of the patient going
through the gantry. The smaller the pitch the longer the scan time and increased patient
dose there is. If the pitch is bigger then it can cause gaps and miss sections of the body
that are needing to be imaged and also degrades contrast.

What is the purpose of windowing (window level and window width) of a set of CT
images? - ANSWER-Allowing the certain tissue to be displayed while the other values
(HU) that are below and above the set window to be out of range with lower intensity.

CT voxel values are given in terms of _______________

, which express the attenuation of a given tissue relative to that of ____________. -
ANSWER-Hounsfield units, water

The two types of x-rays produced in an x-ray tube are

and _____________. - ANSWER-Characteristic, Bremssstrahlung

The x-ray beam used for CT imaging is polychromatic. (True or false) - ANSWER-True

A larger value for pitch indicates higher radiation exposure to the patient. (True or false)
- ANSWER-False

All of the following are true about increasing the kVp setting EXCEPT

A. it selects the maximum possible energy of the x-ray beam
B. it defines the fraction of photons that will reach the detectors
C. it affects the radiation exposure to the patient
D. it increases beam hardening - ANSWER-D. it increases beam hardening

Modern CT scanners rely on _____ to process acquired data.

A. supercomputers
B. mainframe computers
C. minicomputers
D. microcomputer - ANSWER-C. minicomputers

To assure fast scan times and immediate data processing, CT computers depend on:

A. distributed processing.

, B. multitasking
C. multiprocessing
D. parallel processing. - ANSWER-D. parallel processing

Large array parallel processors are responsible for:

A. executing several tasks sequentially.
B. performing numerous tasks simultaneously .
C. assessing faulty detector arrays
D. hardening the x-ray beam. - ANSWER-B. performing numerous tasks simultaneously

Collimators in CT scanning are used to do all of the following EXCEPT

A. limit the beam size
B. reduce scattered x-rays
C. define slice thickness
D. offset the alignment of the tube and detector array to optimize the beam location -
ANSWER-D. offset the alignment of the tube and detector array to optimize the beam
location

Computed tomography (CT) scanning accomplishes all of the following EXCEPT

A. minimal superimposition of tissues
B. improved contrast resolution
C. reduction of radiation dose compared to conventional radiography
D. differentiation of tissue densities - ANSWER-C. reduction of radiation dose
compared to conventional radiography

In a CT scanner, the oil bath that may surround the rotating anode tubes serves to

A. make the tubes rotate more quickly
B. make the tubes rotate more smoothly
C. cool the tubes
D. provide efficient conduction of the current - ANSWER-C. cool the tubes

In an x-ray tube, of the energy applied to the system, the percentage of x-rays that exit
is

A. 1%
B. 10%
C. 50%
D. 99% - ANSWER-A. 1%

The purpose of using an aluminum filter in CT scanning is

A. to absorb the very-low-energy x-rays

Información del documento

Subido en
23 de noviembre de 2024
Número de páginas
14
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$15.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
NursingTutor1
3.9
(459)
Vendido
1697
Seguidores
1073
Artículos
18441
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes