SAMPLE EXAM QUESTIONS FROM NMTCB WEBSITE WITH 100% CORRECT SOLUTIONS

Document preview thumbnail
Vista previa 2 fuera de 6 páginas

SAMPLE EXAM QUESTIONS FROM NMTCB WEBSITE WITH 100% CORRECT SOLUTIONSSAMPLE EXAM QUESTIONS FROM NMTCB WEBSITE WITH 100% CORRECT SOLUTIONSSAMPLE EXAM QUESTIONS FROM NMTCB WEBSITE WITH 100% CORRECT SOLUTIONS According to NRC criteria, which of the following is a misadministration? a. Infiltration of an attempted intravenous injection b. Administration of 10 mCi I-131 instead of the prescribed 9 mCi c. Administration of 20 mCi Tc-99m pertechnetate instead of the prescribed 10 mCi d. Administration of 15 mCi I-131 sodium iodide intravenously instead of orally as prescribed. e. Administration of 5 mCi Tc-99m sulfur colloid to the wrong patient. - ANSWER-d. Administration of 15 mCi I-131 sodium iodide intravenously instead of orally as prescribed. Chromatography testing of technetium radiopharmaceuticals is done to check for: a. Aluminum Contamination b. Molybdenum breakthrough c. Radionuclidic purity d. Radiochemical purity e. Chemical purity - ANSWER-d. Radiochemical purity The use of elliptical and/or body contour orbits in SPECT imaging should result in improved: a. Temporal resolution b. Spatial resolution c. Reconstruction times d. Acquisition times

Vista previa del contenido

SAMPLE EXAM QUESTIONS FROM
NMTCB WEBSITE WITH 100% CORRECT
SOLUTIONS
According to NRC criteria, which of the following is a misadministration?
a. Infiltration of an attempted intravenous injection
b. Administration of 10 mCi I-131 instead of the prescribed 9 mCi
c. Administration of 20 mCi Tc-99m pertechnetate instead of the prescribed 10 mCi
d. Administration of 15 mCi I-131 sodium iodide intravenously instead of orally as
prescribed.
e. Administration of 5 mCi Tc-99m sulfur colloid to the wrong patient. - ANSWER-d.
Administration of 15 mCi I-131 sodium iodide intravenously instead of orally as
prescribed.

Chromatography testing of technetium radiopharmaceuticals is done to check for:
a. Aluminum Contamination
b. Molybdenum breakthrough
c. Radionuclidic purity
d. Radiochemical purity
e. Chemical purity - ANSWER-d. Radiochemical purity

The use of elliptical and/or body contour orbits in SPECT imaging should result in
improved:
a. Temporal resolution
b. Spatial resolution
c. Reconstruction times
d. Acquisition times
e. Patient comfort - ANSWER-b. Spatial resolution

Which of the following variables does not affect spatial resolution in nuclear medicine
imaging systems:
a. Physical design of the collimator
b. Material of which the collimator is constructed
c. Energy of the gamma rays being counted
d. Computer matrix pixel size
e. Byte vs. word acquisition mode - ANSWER-e. Byte vs. word acquisition mode

Full width at half maximum (FWHM) is often used as a measure of:
a. Uniformity
b. Sensitivity
c. Intensity
d. Resolution

, e. Dead time - ANSWER-d. Resolution


According to NRC, an unrestricted area is one in which a person would receive a
radiation dose of less than:
a. 2 mrem/hr
b. 5 mrem/hr
c. 10 mrem/hr
d. 20 mrem/hr
e. 50 mrem/hr - ANSWER-a. 2 mrem/hr

The dose rate during preparation of a radiopharmaceutical is 1.66 mrem/hr. With this
rate reduced by 2 HVLs, how many hours would it take a worker to accumulate 10
mrems?
a. 3
b. 6
c. 12
d. 24
e. 48 - ANSWER-d. 24

In a euthyroid patient, which of the following describes the result of Cytomel (T3)
administration for 8 days prior to a radioactive iodine thyroid uptake?
a. Elevated protein bound iodine
b. Suppressed "cold" nodules
c. Increased thyroid uptake
d. Decreased thyroid uptake
e. No variation in uptake - ANSWER-d. Decreased thyroid uptake

Uncorrected flood field nonuniformities cause ____________ artifacts in tomographic
reconstruction.
a. Irregular
b. Dropout
c. Circular
d. Undulating
e. Linear - ANSWER-Circular

How many 16-bit words of memory are required for a 64 x 64 byte mode image?
a. 2,048
b. 4,096
c. 16,384
d. 32,768
e. 65,535 - ANSWER-a. 2,048

Areas of prolonged retention of Xe-133 in the lungs are associated with:
a. Reduced trapping in the lung
b. Obstructive lung disease

Información del documento

Subido en
23 de noviembre de 2024
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$15.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
NursingTutor1
3.9
(459)
Vendido
1697
Seguidores
1073
Artículos
18441
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes