100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

MACHINIST MATE EXAM, NEWEST 2024 ALL IN ONE DOCUMENT 570 QUESTIONS AND CORRECT ANSWERS

Puntuación
-
Vendido
-
Páginas
5
Grado
A+
Subido en
21-11-2024
Escrito en
2024/2025

MACHINIST MATE EXAM, NEWEST 2024 ALL IN ONE DOCUMENT 570 QUESTIONS AND CORRECT ANSWERS

Institución
MACHINIST MATE
Grado
MACHINIST MATE









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
MACHINIST MATE
Grado
MACHINIST MATE

Información del documento

Subido en
21 de noviembre de 2024
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

What NSTM deals with propulsion and NSTM 231
SSTG Turbines?

Whats type of rotary pump is frequently Simple gear pimp
used as a lubricanting pump on pumpe
and other aux equipment?

What is the normal length of a tapered 3"
plug?

What is installed on a non-condensing Combination exhaust relief valve 2-3 psi above exhaust line pressure
turbone to protect turbine casing from
excessive pressure?

On an SSTG, what protects turbine casing Back pressure trip
from excessive pressure?

When starting an SSTG, what is a minimum 60 degrees
lube oil temp?

What are the four sections of a PQS? Fundamentals, systems, watchstations, qual card

What is the number for a PMS feedback 4790/7B
report?

When should oil coolers be put into When temp of lube oil leaving cooler is 100 degrees
operation on aux machinery?

DFT is designed to operate at what 15 psi and 240-250 degrees
pressure and temp?

What is installed on a centrifugal pump to Wearing rings
eliminate renewing of an entire propellor
and pump casing due to rapid wear?

The federal water pollution control act 1970
was amended in what year?

What is the NSTM for compressed air 551
systems?

What is the max allowable pressure drop 3%
across a fuel oil duplex strainer when
online?

What is the NSTM for general reduction 241
gear?

What is the NSTM for forced draft 554
blowers?

What is the required amount of sodium 10lbs per 1,000 gallons of feed water
nitrate used for a sodium nitrate wet lay
up?

What is the NSTM for insulation and 635
lagging?

What is QA chapter 11? QA forms and instructions

What is QA chapter 12? Submarine preservation

What is QA chapter 13? Wire removal and replacement

What is QA chapter 10? Quality assurance records

What is QA chapter 9? Audits, surveillance, evaluations and assesments

What is QA chapter 3? PQS and training

What is QA chapter 2? Quality maintenance process

, What is QA chapter 4? Welder, brazer, and NDT qualifications

What is QA chapter 5? In process control

When is the current ships maintenance Monthly
project verified and updated?

PMS schedules are categorized in what Cycle, quarterly, weekly
manner?

Multi stage
Main feed pump is classified as what type
High speed
of pump?
Turbine driven

How long must the engine room/fire 2 years
room operating log be kept for?

Main feed pumps are fitted with what two Speed limiting
types of governors? Constant speed

the number of revolutions to major speed 3
change is entered in what column?

Entries for astern pitch are preceded by B
what level?

What is the max allowable super heater 1020 degrees
outlet temp during transition periods of
15mins - 1 hour on a 1200 psig D type
boiler?

What is the first action taken, when you Shift boiler feed water control to remote/manual
are experiencing difficulty in maintaining
boiler water level on an automated ship?

In the engineering bell book, what does I Ahead standard speed
mean?

In the engineering bell book, what does Ahead flank speed
III mean?

In the engineering bell book, what does B Back 1/3 speed
1/3 mean?

In the engineering bell book, what does Z Stop
mean?

In the engineering bell book, what does Back full speed
BF mean?

In the engineering bell book, what does Back emergency speed
BEM mean?

In the engineering bell book, what does II Ahead full speed
mean?

When order received is recorded as RPM 2
in what column?

What QA for is used for testing and QA form 17
inspection?

Boiler high water alarm is set to what +7 inches
parameter

During a white smoke casualty to a boiler, Fuel oil header pressure
what must never be adjusted?

What temp is lube oil maintained on an 120-130 degrees
operating main engine?
$31.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
ProfIby

Conoce al vendedor

Seller avatar
ProfIby University of Pennsylvania
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
5
Miembro desde
1 año
Número de seguidores
1
Documentos
1518
Última venta
4 meses hace
Prof Iby

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes