50/125 microns represents a single mode fiber size - answer-False- Single mode fiber is 8/10 microns Cable that is resistant to water damage is - answer-loose tube Composite cables have only fiber - answer-false- they also have copper Connector - answer-non permanent connections Damage to fiber optic cable caused by excessive pulling can be reversed by sending the cable back to the factory. True Or False? - answer-False Distribution cables use mass fusion splicing - answer-False- Ribbion cable uses mass fusion double-stick tape can be used for - answer-collecting and disposing of bare fiber ends. fiber is pulled on the? - answer-Strength Member Fiber optic joints should have - answer-low loss and high mechanical strength For long cable pulls, - answer-the pull should be split up into two or more stages. For safety, all fiber optic work areas must - answer-have sufficient work space Fusion Splicers should not be used - answer-in places that may contain flammable gasses Fusion splicing - answer-permanent singlemode connection In graded index multi mode fiber, does the light travel faster near the center or the outside of the core? Why? - answer-Travels faster outside because the slight change in glass type in order for all rays of light to reach the end at the same time. Installed fiber must be - answer-documented, tested, and terminated correctly. instrument for checking continuity fiber tracing - answer-visual fault locator instrument for checking duplex connector polarity - answer-visual fiber tracer instrument for connector faults such as dirt scratches - answer-Inspection microscope instrument for fault location, splice loss - answer-OTOR graph instrument for insertion loss - answer-Light source and power meter instrument for source or receiver power - answer-power meter Large core step-index is the most common in plastic optical fiber - answer-True List five causes of attenuation in fiber optic connections. - answer-Cores don't line up, NA Miss-Match/wrong patch cord, Dirt on connector, Under polished, End Angle, End Gap, Coaxiality, Axial Run-out, Concentricity, Core ellipticity. List five steps for a mechanical connector installation. - answer-Strip Wire, Clean, Cleave, insert and lock in place, Test. List the Color Code in Order. - answer-Blue Orange Green Brown Slate White Red Black Yellow Violet Rose Aqua List the tools and supplies required for preparation of the ends of tight buffer tube cables. - answer-Razer, strippers, scissor, glasses, closed toe shoes, tape, rubber mat, sufficient work space. Loose tube may require the instalation of what - answer-Breakout kit mechanical splicing - answer-restoration or multimode joints Most singlemode field terminations are made by - answer-fusion splicing a factory pigtail onto the cable Multimode Fiber has a greater bandwidth than single mode fiber - answer-False - Single mode has less dispersion: more bandwidth No fiber optic cable needs to be grounded - answer-False - any electronic material must be grounded Orange cable contains multimode fiber - answer-True Outside cable resistant to rodents - answer-Armored cable Pulling from the center to the ends is a way of pulling long cables in conduits - answer-True Single mode fiber cables are usally color coded in gray - answer-Fase - Yellow Telcom Fttx is typically - answer-single mode fiber Telecom FTTx is typically single mode fiber - answer-True The cable that is used indoors in air handling areas is - answer-plenum rated cable The cladding is the portion of the fiber you are removing during stripping - answer-The buffer is what you take off The most important safety concern specific to fiber optics is? - answer-Shards of bare fibers getting stuck in skin or eyes. The reference cables that are used during testing must be chosen for their low loss characteristics - answer-True The testing phase of a project is when you do loss/budget anaylisis - answer-False - should be done in the planning stage Unit for measuring absoulute power - answer-dBm Unit for measuring bandwidth - answer-GHz Unit for measuring cable length is - answer-Feet or meters

Mostrar más Leer menos
Institución
FOA- Fiber Optic Certification
Grado
FOA- Fiber Optic Certification








Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
FOA- Fiber Optic Certification
Grado
FOA- Fiber Optic Certification

Información del documento

Subido en
19 de noviembre de 2024
Número de páginas
4
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

FOA- Fiber Optic Certification Exam T/F
50/125 microns represents a single mode fiber size - answer-False- Single mode
fiber is 8/10 microns

Cable that is resistant to water damage is - answer-loose tube

Composite cables have only fiber - answer-false- they also have copper

Connector - answer-non permanent connections

Damage to fiber optic cable caused by excessive pulling can be reversed by sending
the cable back to the factory. True Or False? - answer-False

Distribution cables use mass fusion splicing - answer-False- Ribbion cable uses mass
fusion

double-stick tape can be used for - answer-collecting and disposing of bare fiber
ends.

fiber is pulled on the? - answer-Strength Member

Fiber optic joints should have - answer-low loss and high mechanical strength

For long cable pulls, - answer-the pull should be split up into two or more stages.

For safety, all fiber optic work areas must - answer-have sufficient work space

Fusion Splicers should not be used - answer-in places that may contain flammable
gasses

Fusion splicing - answer-permanent singlemode connection

In graded index multi mode fiber, does the light travel faster near the center or the
outside of the core? Why? - answer-Travels faster outside because the slight change
in glass type in order for all rays of light to reach the end at the same time.

Installed fiber must be - answer-documented, tested, and terminated correctly.

instrument for checking continuity fiber tracing - answer-visual fault locator

instrument for checking duplex connector polarity - answer-visual fiber tracer

instrument for connector faults such as dirt scratches - answer-Inspection
microscope

instrument for fault location, splice loss - answer-OTOR graph

instrument for insertion loss - answer-Light source and power meter
$10.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TOPDOCTOR Abacus College, Oxford
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
10
Miembro desde
2 año
Número de seguidores
5
Documentos
3396
Última venta
3 meses hace
TOPGRADER!!

Looking for relevant and updated study material to help you ace your exams? TOPTIERGRADES has your back!!! I have essential exams, test-banks, study bites, assignments all graded A+, Have Complete solutions, and are updated regularly. Please feel free to message me if you are looking for a specific test bank that is not listed on my profile or want a test bank or exam sent to you directly as google doc link. In the event that any of the materials have an issue, please let me know and I\'ll do my best to resolve it or provide an alternative. Thank You & All The Very BEST!!!!!

Lee mas Leer menos
5.0

1 reseñas

5
1
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes