When a device is inaccessible due to excessive height, such as an
atrium, what it the maximum interval for testing? -ANSWER-18
months

When installing a wall-mounted fire telephone appliance to the public,
what is the acceptable maximum mounting height from the floor? -
ANSWER-66 inches

Elevator lobby smoke detectors shall be mounted within a maximum
of which distance from the center-line of the door? -ANSWER-21 feet

At minimum, when working near power lines with voltage of 600 volts
and lower, an aerial lift operator shall maintain which distance from the
lines? -ANSWER-10 feet

The use of unprotected EMT shall be permitted under which
conditions? -ANSWER-when in direct contact with the earth

According to NFPA 70, what is the maximum unsupported length of
1/2-inch flexible metallic conduit where flexibility is required after
installation? -ANSWER-4 1/2 feet

What is the maximum bend (in degrees) permitted in a conduit run
between outlet boxes? -ANSWER-360 Degrees

,If the primary power is disconnected and the fire alarm system goes
into an alarm condition, what is the minimum acceptable time for
secondary power to operate the voice evacuation systems? -
ANSWER-15 minutes

A riser room temperature switch should activate when the temperature
falls below which level? -ANSWER-40 degrees F

According to NFPA 72, what is the maximum sound pressure level
permitted in a space with notification appliances? -ANSWER-110 dBA

What is the minimum interval for testing a single-station smoke
detector in multifamily units? -ANSWER-Annually

Where should a technician install a detector in relation to beam that is
less than 12 inches deep and less that 8 feet in center? -ANSWER-At
the bottom of the beam

An existing fire alarm cable in a drop ceiling will be spliced. which one
of the following splice locations will comply with NFPA 70? -ANSWER-
secured inside a listed box or enclosure

Which function shall be tested for each newly installed smoke
detector? -ANSWER-smoke entry?

An 180 foot long corridor is 10 feet wide, with a smooth 10 foot ceiling,
interrupted by 4-inch beams spaced every 10 feet. How many heat
detectors with a listed 30 foot spacing are required? -ANSWER-6 heat
detectors

At which height must cables be physically protected when being
installed within an exposed ceiling? -ANSWER-7 feet

,When shall smoke detectors be installed during the construction
process? -ANSWER-After the final cleanup of all trades

Where structural members are provided, intermediate metal conduit
shall be secured within which maximum distance from an outlet box" -
ANSWER-3 feet

The requirement forbidding fire alarm circuits from being T-tapped,
unless indicated by the manufacturer's instructions, is intended to
prevent which type of improper malfunction? -ANSWER-monitoring
integrity of installation conductors?

What is the maximum operating temperature of TW insulation? -
ANSWER-140 Degrees F, Table 310.15 (B)(16)

Which type of meter is used to measure the current draw of a strobe
circuit? -ANSWER-multimeter

What is an acceptable document for finding information on spacing of
video imaging smoke detection systems? -ANSWER-shop drawings in
submittal package

When pulling multiple cable through a junction box, the installer must
leave which minimum length of wire for splicing? -ANSWER-6 inches
of wire

Which three of the following conditions are symptoms of a heart
attack? -ANSWER-heartburn, pain in chest, shortness of breath

, Sprinkler water storage containers shall be supervised to indicate
what the water temperature drops to which level? -ANSWER-40
degrees F

According to NFPA 72, what is the minimum separation between
outgoing and returning conductors for a Class A loop that is
horizontally placed down to an 8 foot-wide corridor? -ANSWER-4 feet
of separation

According to NFPA 72, a public emergency alarm reporting system
shall operate its emergency power source for which minimum time
period? -ANSWER-10 minutes

Where shall employers post a safety data sheet? -ANSWER-in the
technician's work area

According to NFPA 72, during an acceptance test, which method can
be utilized for testing a sprinkler waterflow switch? -ANSWER-Open
the inspector's test valve to cause an actual flow of water, ensure that
the control panel receives the alarm within 90 seconds

I'm technicians are working in a plant, remind to learn of the plants
safety regulations? -ANSWER-from OSHA regulations?

When into a telephone communication system is required, at least one
telephone or Jack shall be installed in which of the following locations?
-ANSWER-in a fire pump room

Who is responsible for fire alarm system and testing and
maintenance? -ANSWER-Property owner

Escuela, estudio y materia

Institución
NICET Fire Alarm
Grado
NICET Fire Alarm

Información del documento

Subido en
14 de noviembre de 2024
Número de páginas
32
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$18.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Tutorhailey Walden University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
30
Miembro desde
3 año
Número de seguidores
14
Documentos
354
Última venta
7 meses hace
The bookstore

Find all past papers and revision material here

4.5

4 reseñas

5
2
4
2
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes