100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

ABYC Marine Systems Questions With Correct Detailed Answers.

Puntuación
-
Vendido
-
Páginas
24
Grado
A+
Subido en
13-11-2024
Escrito en
2024/2025

ABYC Marine Systems Questions With Correct Detailed Answers.

Institución
ABYC Marine Electrical
Grado
ABYC Marine Electrical










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ABYC Marine Electrical
Grado
ABYC Marine Electrical

Información del documento

Subido en
13 de noviembre de 2024
Número de páginas
24
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ABYC Marine Systems 2022-2023
Questions With Correct Detailed
Answers.
1. What is the most often used material for a potable water system? - ANSWER-
Polyethylene

. Name 5 materials allowable for contact use in potable water systems: - ANSWER- 1.
Copper Alloys (incl. bronze, brass and nickelcopper) 2. AISI Type 300 series stainless
steel
3. Glass-lined metal
4. FDA approved plastic 5. FDA approved rubber

What device can be used to separate potable water from other water systems? -
ANSWER- Siphon Break

What is the device used to maintain a stable pressure and minimize pump cycling, and
where should it be located? - ANSWER- Accumulator Tank, after pump/filter and before
check- valve

At what what percentage of nominal working pressure shall a water heater relief valve
be set? - ANSWER- 175%

Is a standard household type relief valve acceptable for hot water tanks? - ANSWER-
No, typically these are too high (up to 400% of nominal pressure)

For the pressure reducing valve and check valve installed after a shore water
connection, what is the maximum allowable pressure?r - ANSWER- nominal working
pressure, not to exceed 80 PSI

Where shall the storage tank be vented? - ANSWER- overboard

. What is the maximum allowable pressure to which a storage tank and vent system be
subjected? - ANSWER- 3 PSI or mnfg's maximum, which ever is greater.

What temperate range is required for pumps to be able to tolerate exposure? -
ANSWER- -40 °F to +140 °

When operating at an ambient temperature of 140 F, what is the max allowable surface
temperature of a pump? - ANSWER- 257 F

A potable water systems tank must be equipped with a drain. T or F? - ANSWER- True

,. Storage tank inlets may also serve as the tank vent. T or F? - ANSWER- False

Storage tank inlet caps must be retained to prevent loss. T or F - ANSWER- True

Storage tanks must be equipped with a vent. T or F? - ANSWER- True

Storage tank vents may be used for filling purposes. T or F? - ANSWER- False

What rate of static pressure must a storage tank withstand? - ANSWER- At least 1.5X
the pressure exerted by the distance from the tank bottom to the deck fill plate or vent,
but not less than 3 PSI.

What is the max pressure that a desalinator can impart to a storage tank? - ANSWER- 3
PSI

Each desalinator must be equipped with an automatic shutoff salinity detector. T or F? -
ANSWER- True

What marking must be on pipe or tubes that are not capable of handling hot water? -
ANSWER- "For Cold Water Use Only"

What is the test pressure for water heater tank 15 gal or less? over 15 gal but under 120
gal? - ANSWER- 125 PSI, 300 PSI

What is the max temperature relief setting for hot water tanks? - ANSWER- 210 F

What is the max allowable water output temperature for hot water system? - ANSWER-
125 F

All potable water system connections shall be positioned above the normal bilge water
accumulation level. T or F? - ANSWER- True

. Exposed metallic parts of a potable water system shall have provisions for electrical
bonding. T or F? - ANSWER- True

For what reason might a holding tank collapse during pump-out? - ANSWER- Improper
venting

What type of MSD (Marine Sanitation Device) discharges effluent with fecal coliform
bacteria count <= 1,000 (per 100 ml) and no suspended solids? - ANSWER- Type I

What type of MSD (Marine Sanitation Device) discharges effluent with fecal coliform
bacteria count <= 200 (per 100 ml) and <= 150 mg suspended solids per liter? -
ANSWER- Type II

, What type of MSD (Marine Sanitation Device) is designed to hold sewage or any waste
derived from sewage? - ANSWER- Type III

What is the name given to the complete system including toilets, hoses, pipes, holding
tanks and fittings designed to receive, retain, vent and pump out sewage? - ANSWER-
Retention System

What is the name of the system that includes all sanitation equipment and fittings
designed to receive, treat, vent and discharge sewage? - ANSWER- Treatment System

What is another name for a vented loop that prevents back siphoning by breaking
suction yet allowing normal flow when pressurized? - ANSWER- Siphon break

When calculating holding tank size, how many flushes per day are included in the
calculation? - ANSWER- 5

What volume of human waste is used per flush when calculating holding tank size? -
ANSWER- 0.14 gallons

True or False: If a portable toilet is secured and fitted with a deck pump-out fitting and
vent it qualifies as a type III device. - ANSWER- True

Why must careful consideration be given to the location and routing of inlet and
discharge lines for manual flush toilets when the "shut-off" merely bleeds air into the
inlet line? - ANSWER- Prevention of siphoning

. When and why must siphon breaks be installed in a sewage system? - ANSWER-
Whenever components are installed below the max heeled water line - to prevent back
flow into the vessel or unintentional siphoning of untreated effluent overboard.

A seacock may be installed instead of a siphon break to prevent discharge and back
siphoning. T or F? - ANSWER- True

. What special provision must be included for a sewage y-valve when the discharge
seacock is not lockable? - ANSWER- The handle must be lockable in the direction of
the holding tank

Name four ways to separate a fresh water flushing system from potable water system. -
ANSWER- Air Gap, Vacuum Break, Double Check Valve, Dedicated Water Tank

. What is the minimum hose ID for use on un-macerated sewage? - ANSWER- 1.5
inches

What provisions should be made if using rigid PVC for sewage? - ANSWER- Secure
mounting to minimize vibration effect, use flexible hose to connect to fitting and hull.
$10.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Divinehub Exam
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
275
Miembro desde
3 año
Número de seguidores
172
Documentos
4250
Última venta
1 mes hace
NURSING EXAMS AND STUDY GUIDES

Welcome to the best educational world with the brightest, most amazing, and all complete study materials. I wish you great,easy learning and success throughout your course. Kindly message me if you can\'t find your tutorials

3.9

45 reseñas

5
24
4
6
3
8
2
0
1
7

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes