Detailed Answers.
Every 18 inches. - ANSWER- How often (in inches) shall wire bundles be supported?

Insulated Metallic Hanger Clamps - ANSWER- What type of clamps are to be used for
supporting wire bundles when routed over engines and machinery?

40 lbs (E-11 Table XV) - ANSWER- What tensile force must a 10 Gauge crimp
connector withstand for one minute?

36 inches - ANSWER- What is the max allowed unsupported cable length for battery
cables?

True - ANSWER- T or F: Running AC and DC conductors together is allowed so long as
the AC conductors are sheathed.

C. Unwanted open - ANSWER- The most common electrical circuit problem in marine
applications is:
A. Short circuits
B. Too much continuity
C. Unwanted open
D. Inter circuit Short

D. Heat - ANSWER- The primary by-product of excessive electrical resistance is:
A. Increased Amperage
B. Increased Voltage
C. Reduced Ambient Temperature
D. Heat

1 HP = 746 Watts - ANSWER- One HP = how many watts?

D. TDR (time-domain reflectometer) - ANSWER- What is the preferred tool for tracing
shorted and open circuits?
A. Ohm meter
B. Amp clamp
C. Volt meter
D. TDR (time-domain reflectometer)

0 AWG - ANSWER- A technician is installing a cable run from the batteries to the main
DC panel board on a boat as part of a refit. The boat has a 12-volt system and the

,distance form the panel to the batteries is 15 ft. The maximum current draw from the
panel is calculated at 90 amps. What guage cable should be used (minimum)?

Yellow - ANSWER- DC grounded conductors on new boats that are also equipped with
AC systems should use what color insulated wire?

16 AWG - ANSWER- What is the smallest guage wire allowed for unsheathed wire runs
through the boat?

False. Start batteries have a greater number of thinner plates within each cell. -
ANSWER- T or F: Compared to deep cycle (house) batteries, cranking batteries will
have thicker lead plates to facilitate the higher, short-duration current draws.

Cranking - ANSWER- Which type of battery generally recharges faster? Deep cycle or
cranking?

Wire brush and backing soda. - ANSWER- What tool and common household staple are
used to clean battery terminals?

Most of the sulfuric acid has been absorbed into the lead plates, leaving mostly water in
the electrolyte. - ANSWER- Why might a fully-discharged wet-cell type battery freeze?

1 inch, 90 lbs or 2x the battery weight, for 1 minute in each direction. - ANSWER-
Batteries must be secured to prevent movement of more than ______ inches in any
direction when a pulling force of _____ or _____, whichever is less, is applied through
the center of gravity of the battery for how long?

True - ANSWER- T or F: it is ok to install batteries directly below an uninterrupted fuel
line?

Must be protected with dielectric insulating material - ANSWER- What provision must be
in place on any fuel line located within 12 inches of a battery terminals?

80 F, 25 Amps, 10.5 Volts - ANSWER- Define: Battery reserve capacity = the number of
minutes that a new, fully charged battery at ______ degrees F can be continuously
discharged at ______ amps while maintaining _____ volts (for a 12 v battery)

90 minutes - ANSWER- According to ABYC, what is the minimum battery reserve
capacity?

32 degrees F, 30 seconds, 7.2V - ANSWER- Define: Marine Cranking Amps = the
discharge load, in amperes, that a new, fully-charged battery at _____ degrees F can
deliver for ______ seconds while maintaining a voltage of _____ volts (for a 12 v
battery).

,0 degrees F, 30 seconds, 7.2V - ANSWER- Define: Cold Cranking Amps = the
discharge load, in amperes, that a new, fully-charged battery at _____ degrees F can
deliver for ______ seconds while maintaining a voltage of _____ volts (for a 12 v
battery).

8 AWG - ANSWER- What is the largest guage wire that may be connected to a bettery
with wing-nuts?

800 CCA or 100 Ahr (exceptions: electronic equipment with battery backed memories;
safety equipment such as bilge pumps, alarms, CO detectors, bilge blowers; battery
chargers; I'm pressed current systems. - ANSWER- Per ABYC E-10, a battery switch
must be installed in the positive conductor from each battery bank with a CCA rating
greater than ____ (or greater than _____ Ah if CCA rating not available).

AIC = 5000 Amps (E-11 table IV-A) - ANSWER- What is the minimum ampere
interrupting capacity (AIC) for main overcurrent protection on a battery bank rated at 12
V, 1500 CCA?

AIC = 2X mnfg's short-circuit rating or 100X nominal Ahr rating. - ANSWER- What is the
minimum ampere interrupting capacity (AIC) for main overcurrent protection on a
battery bank rated at more than 2200 CCA or more than 500 Ahr?

False. "Readily accessible" defines entry into the engine room in an emergency as
dangerous - use a remote battery switch. - ANSWER- T or F: it is ok to mount a battery
switch inside an engine room, because ABYC startes that it must be located as close to
the batteries as practical.

Overcurrent protection must be located withing 7 inches of the power source unless
contained within a sheath, in which case it may be up to 40 inches away. If the power
source is a battery and the conductors are sheathed, OC may be up to 72 inches away.
- ANSWER- Explain the "7-40-72" rule

Resetting mechanism cannot overrid over current interrupting mechanism. (Note: some
residential breakers are not trip free) - ANSWER- What does "trip free" breaker mean?

C. 14.1 V - ANSWER- The maximum sustained charging voltage acceptable to some
gell cell battery manufacturers is:
A. 13.8 V
B. 14.5 V
C. 14.1 V
D. 13.2 Vll

0.050 points of specific gravity below other cells = bad cell. - ANSWER- When testing a
wet-cell battery with a hydrometer, what threshold is used to determine a bad cell?

, 1.260 - 1.285 (temperature dependent) - ANSWER- When testing a wet-cell battery with
a hydrometer, what reading indicates a fully charged battery?

50% - ANSWER- When testing a fully charged start battery for capacity with a load
tester, what % of CCA rating should be induced by the load to test resulting voltage?

C. Between 150% and 200% - ANSWER- Most engine-driven alternators are optimally
spun at what percentage of engine RPMs?
A. Between 10% and 50%
B. Less than 10%
C. Between 150% and 200%
D. Greater than 200%

False. the battery charger case shall be tied to the engine negative terminal/bus, along
with the negative output terminal of the battery charger, not at the battery charger case
itself., - ANSWER- T or F: A battery charger case shall be tied to the DC negative
output terminal at the battery charger.

In case of an internal short to the case, the AC grounding wire would not carry enough
current. - ANSWER- Why do battery chargers require a separate case connection to
main AC grounding bus and Engine negative / DC grounding bus?

No smaller than 1 size below the DC current carrying conductors between the charger
and batteries - provided OC protection on positive DC output is no greater than 135% of
DC grounding cable ampacity and conductor is no smaller than 16 AWG. - ANSWER-
What is the minimal wire size required for a battery charger case connection to DC
ground/engine negative?

Class T fuse rated for appropriate AIC - ANSWER- What device is typically found to
satisfy the required OC protection between a battery charger and the batteries?

Batteries will feed back into solar array or wind generator coil and discharge (possibly
damage). Note: many voltage regulators have integral blocking diodes. - ANSWER-
What may happen to a solar array or wind generator used to charge batteries without a
blocking diode?

24 inches or more (unless waterproof!) - ANSWER- How far above bilge water level
must a battery charger be mounted?

At least 24 inches - ANSWER- How far away from a gasoline tank must a pre-wired
battery charger's AC connection plug be located?

False. (only when installed in location that required GFCI per ABYC E-11) - ANSWER-
T or F: All marine inverters shall utilize an internal or external GFCI on their AC outlets.

Información del documento

Subido en
13 de noviembre de 2024
Número de páginas
37
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$10.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Divinehub
3.8
(47)
Vendido
284
Seguidores
172
Artículos
4253
Última venta
3 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes