100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

North Carolina Home Inspection Licensing Exam Study Guide (Verified Solution).

Puntuación
-
Vendido
-
Páginas
26
Grado
A+
Subido en
11-11-2024
Escrito en
2024/2025

North Carolina Home Inspection Licensing Exam Study Guide (Verified Solution).

Institución
North Carolina Home Inspection Licensing
Grado
North Carolina Home Inspection Licensing










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
North Carolina Home Inspection Licensing
Grado
North Carolina Home Inspection Licensing

Información del documento

Subido en
11 de noviembre de 2024
Número de páginas
26
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

North Carolina


North Carolina Home Inspection Licensing
Exam Study Guide (Verified Solution).
The ________ and _________ breaker panels are known to be major electrical fire hazards and have
been recalled. - ✔✔✔ - FPE Stab-lok and Zinsco



The service drop cable running over a 4:12 or greater pitch roof has to be ____ over the ridge. -
✔✔✔ - 3'



If you have a 8 gauge stranded aluminum cable running to a 40 amp breaker that goes to an
electric stove and a 10 gauge single strand copper cable running to a 40 amp breaker that goes
to the condenser unit, which one is wrong and how would you fix it? - ✔✔✔ - The aluminum
wire is too small for the breaker, it requires a 6 gauge wire



In the sub panel the grounding bus bar has been bonded to the neutral bus bar, this action is
called what? - ✔✔✔ - Parallel Paths



Indoor staircases are required to have a three-way switch at the top and bottom if they have __
or more risers. - ✔✔✔ - 6



In a complete circuit the ___ wire carries the current with no energy back to the source. - ✔✔✔
- Neutral



Every Home must have at least __ plumbing Vents extending through the roof by at least __
inches. - ✔✔✔ - 1 and 6 inches



Minimum size for the bathroom drain fixtures? - ✔✔✔ - 1 ¼ in




Home Inspection Licensing

,North Carolina


Must have a union fitting on all pipes within __ feet of the water heater? - ✔✔✔ - 5 ft



What does the R-Value mean in attic Insulation? - ✔✔✔ - Resistant



Electric Safety eye sensor should be __ Inches from floor? - ✔✔✔ - 3 - 6"



With a vapor Barrier there should be __ Sqft per __ of attic Space? - ✔✔✔ - 1 sq ft per 300 Sq ft



What should a steam boil have to prevent cross connections? - ✔✔✔ - BFP: back flow
preventer



_______ are any material which allow its electrons to move through the material. - ✔✔✔ -
Conductors



A complete circuit must include a ______. - ✔✔✔ - Load



The amount of energy is known as _____. - ✔✔✔ - Amps



The pressure behind electrical current is _____. - ✔✔✔ - Volts



The resistance to current flow is known as ______. - ✔✔✔ - Ohms



Higher Amp circuits need thicker wire gage because more amps generate more _____. - ✔✔✔ -
Heat




Home Inspection Licensing

, North Carolina


The rate of work or power is known as _____ . - ✔✔✔ - Watts



Doubling the ____ quadruples the amount of ____ generated. - ✔✔✔ - Current / heat



Service ____ are overhead from a utility pole and service ____ are underground from a utility
trench. - ✔✔✔ - Drops / Laterals



The neutral wire has the same _____ as the black/hot wire but does not have the ____ to shock
you. - ✔✔✔ - Amps / Energy



How many wires in a Three Phase service drop cable? - ✔✔✔ - 4, (3) 120 volts and (1) neutral



A Mansard style of roof is most likely to have leaks where? - ✔✔✔ - The eyebrows



You are inspecting a 25 year old roof that has cedar shakes, the full length of the shake is 24",
how much of the cedar shake can be exposed? - ✔✔✔ - 8" / ⅓ of the shingle



_____ is a moisture protection barrier that is installed on top of the roof sheathing prior to
installing shingles. - ✔✔✔ - Underlayment



You are inspecting a home in December that has architectural shingles and notice ice damming
around the eaves and gutters of the roof, what are two things that could cause this? - ✔✔✔ -
Lack of ventilation and Lack of Insulation in the attic



______ flashing is always interwoven with each course of roof material, starting at the eaves
(bottom roof edge) and working up. - ✔✔✔ - Step Flashing




Home Inspection Licensing
$15.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Boffin Harvard University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1775
Miembro desde
4 año
Número de seguidores
1469
Documentos
7146
Última venta
1 día hace
Pilot Study

Prevent resits and get higher grades.

3.8

438 reseñas

5
210
4
76
3
71
2
16
1
65

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes