Answers with complete solution
The type and extent of each special inspections shall be located in? - -The statement
of special inspections -IBC 1704.3.1
Who has the legal authority to enforce a special inspections provision building code? -
-building official -SIM page. 28 -page30
Who can hire an approved inspection agency? - -Owner or owner agent -IBC 1704.2
Who can perform a structural observation? - -Registered design professional - IBC
1704.5
Who is required to receive the final report? - -Owner's or owners authorized agent -SI
Manual pg. 18
All of the following should be performed by the special inspector on the job site, except.....
- -Stop work when nonconforming items are observe _SIM pg. 12
Who is responsible for providing access to the approved plans? - -General contractor
- SIM pg.28
Who shall the special inspector demonstrate competence to? - -Building official -
IBC 1704.2.1
Who can issue stop work order? - -Building official -SIM pg. 30
What type of inspection is required for post-installed adhesive anchors (epoxy) placed in a
horizontal position to an existing 3000 PSI concrete wall? - -Continuous special
inspections-IBC table 1705.3
Which of the following does not need to be on a daly report containing non-conforming
items? - -A propose solution from the special inspector -SIM pg. 18
Discrepancies should be brought to the immediate attention of
the_________________________ - -Contractor -IBC 1704.2.4
, General Requirements ICC All Possible Questions and
Answers with complete solution
Foundation walls built per table 1807. 1.6.2 require what extent of special inspection? -
-None at all -IBC 1705.3 exemption 4
Who must the special inspector notify of their presence on a job site? - -Contractor-
SIM page. 17
When must the statement of special inspections be submitted? - -For permit
issuance - IBC 1704.2.3
The special inspector is required to verify all of the following except....... - -Design
data from concrete mix and approve it - IBC Table 1705.3
A __________________ Is a classification assigned to a structure based on its risk category
and the severity of the design earthquake ground motion at the site. - -Seismic zone -
IBC pg. 36/32
A special inspector is responsible fo all the following except...... - -Approving RFI's -
SIM pg.11/12
Placement of 3000 PSI concrete for grade beams and sampling for fabricate strength
specimens requires what type of special inspection? - -Continuous - IBC 1705.3
Who is responsible for preparing statements of special inspections? - -Register
design professional - IBC 1704.3
All of the following should be on a daily report except..... - -Man count for the rebar
contractor - SIM pg.18
The special inspector shall furnish daily inspections report to the___________________
and_________________. - -Building official and register design professional - IBC
1704.2.4
A special inspector is responsible for all the following except.... - -Structure
observation - IBC 1704.6