NICET Level 2 Water-Based Systems Exam (Latest Update) Questions and Answers (100% Correct) NICET Level 2 Water-Based Systems Exam (Latest Update) Questions and Answers (100% Correct)

Institución
NICET Level 2 Water-Based Systems
Grado
NICET Level 2 Water-Based Systems










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NICET Level 2 Water-Based Systems
Grado
NICET Level 2 Water-Based Systems

Información del documento

Subido en
7 de noviembre de 2024
Número de páginas
16
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NICET Level 2 Water-Based Systems Exam
(Latest Update2024-2025) Questions and
Answers (100% Correct)
Where located above floor (within 2.1m or 7ft.) cables shall be securely fastened at intervals of ANSWER>>

not more than 18 inches




Which cable types can be installed in fireproof riser shafts ANSWER>>

FPLP, FPLR, and FPL




How many THHN conductors can fit in a 3/4 size Rigid PVC conduit ANSWER>>

17




This is the defined as the height from the continuous floor of a room to the continuous ceiling of a room
or space ANSWER>>

Ceiling height




The visible annunciation of the location of operated initiating device shall not be ANSWER>>

by the means used to deactivate alarm notification appliances.




Subsequent trouble signals shall cause trouble notification appliances to activate as required by what
ANSWER>>

system input/ output matrix

,System equipment shall be maintained in accordance with what ANSWER>>

Manufacturer's published instructions




The detector sensitivity shall not be tested or measured using any device that administers ANSWER>>

an unmeasured concentration of smoke or other aerosol into the detector or smoke alarm




Sensitivity shall be checked within how long ANSWER>>

1 year after installation




Where partitions extend to within 15% of the ceiling height, the spaces separated by the partitions shall
be ANSWER>>

considered separate rooms




Spot-type heat detectors shall include ANSWER>>

Response time index




The first line of detectors shall be located at or within ANSWER>>

36 inches of the peak of the ceiling




Smoke detectors shall be marked with ANSWER>>

with their nominal production sensitivity and tolerance in in percent per foot obscuration

, Spot-type smoke detectors shall be permitted to be located on ceiling or on the bottom of beams for
ceilings with beam depths of ANSWER>>

less than 10% of the ceiling height.




If any barrier, such as a door, curtain, or retractable partition is located in sleeping areas, sound pressure
level shall be measured ANSWER>>

with the barrier placed between the appliance and pillow




Appliances intended for use in special environments, such as outdoors vs. indoors shall be what
ANSWER>>

listed for the intended purpose




In-building emergency mass notification system shall be permitted to be initiated how ANSWER>>

by manual or automatic means




Any signal received by the supervising station that has not restored to normal condition within 24 hours
of initial receipt shall be re-displayed to an operator as a nonrestored signal and shall be ANSWER>>

reported to the subscriber




All operator controls at the proprietary supervising station shall be ANSWER>>

operated at each change of shift
$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
kiarienaomi88 Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
187
Miembro desde
1 año
Número de seguidores
11
Documentos
3369
Última venta
6 días hace
I am a PhD student at Chamberlain College of Nursing. I provide a wide range of thoroughly tested and proven nursing documents. These documents are 100% authentic and have been verified. Browse through my collection to find the most relevant resources to

I am a PhD student at Chamberlain College of Nursing. I provide a wide range of thoroughly tested and proven nursing documents. These documents are 100% authentic and have been verified. Browse through my collection to find the most relevant resources to help you improve your scores.

3.5

25 reseñas

5
10
4
4
3
5
2
1
1
5

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes