Charging a heat pump with refrigerant is best accomplishes in the _____ mode. correct answers Cooling mode Heat pumps can provide both heating in the winter and cooling in the summer. In which mode is the heat pump more efficient? correct answers Heating mode Which of the following components is exclusive to the heat pump? correct answers Reversing valve Which of the following airflow rates is the most reasonable for a heat pump system operating in the heating cycle? correct answers 450 cfm per ton During the heat pumps cooling cycle, the outdoor coil is utilized as a _____ while the indoor coil is utilized as a _____. correct answers Condenser, Evaporator Heat is present in winter outdoor air until the outside air ambient temperature reaches a low temperature of: correct answers -459 degrees F The heat pump utilizes: correct answers Some use of the bi-flow filter drier and others use two filter driers with check valves The correct way to size a heat pump is to perform both heating and cooling load calculations and select the heat pump size by: correct answers Using the cooling load to size the system Auxiliary electric heat is necessary because: correct answers -It provides heat for the home during defrosts -It provides heat for the home in the event of a heat pump failure -It provides heat for the home if the heat pump is unable to meet the demand for heat Reading a voltage across the contracts of the outdoor thermostat means: correct answers The thermostat contacts are open What is not a type of heat pump? correct answers Direct coupled The coefficient of performance is determined by: correct answers Dividing the input btuh by the output btuh The "balance point" of a heat pump is: correct answers The lowest temperature at which the heat pump can meet the heating requirement for the structure

Mostrar más Leer menos
Institución
NATE HEAT PUMPS
Grado
NATE HEAT PUMPS








Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NATE HEAT PUMPS
Grado
NATE HEAT PUMPS

Información del documento

Subido en
5 de noviembre de 2024
Número de páginas
3
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NATE HEAT PUMPS

Charging a heat pump with refrigerant is best accomplishes in the
mode. correct
answers Cooling
mode
Heat pumps can provide both heating in the winter and cooling in the
summer.
mode In which
is the heat pump more efficient? correct answers
Heating mode
Which of the following components is exclusive to the heat pump?
correct answers
Reversing
valve
Which of the following airflow rates is the most reasonable for a heat
pump system
operating in the heating cycle? correct answers 450
cfm per ton
During the heat pumps cooling cycle, the outdoor coil is utilized as a
while the
indoor coil is utilized as a . correct answers Condenser,
Evaporator
Heat is present in winter outdoor air until the outside air ambient
temperature
low temperature reaches a
of: correct answers -459
degrees F
The heat pump utilizes: correct answers Some use of the bi-flow filter drier
and two
use others
filter driers with check
valves
The correct way to size a heat pump is to perform both heating and
cooling load and select the heat pump size by: correct answers Using the
calculations
cooling
to load
size the
system
Auxiliary electric heat is necessary because: correct answers -It provides
heat for
home the
during
defrosts
-It provides heat for the home in the event of a heat
pump
-It failureheat for the home if the heat pump is unable to meet the
provides
demand for heat
Reading a voltage across the contracts of the outdoor thermostat
means: correct
answers The thermostat contacts are
open
What is not a type of heat pump? correct answers Direct
coupled
The coefficient of performance is determined by: correct answers
Dividing
btuh the output
by the input
btuh
The "balance point" of a heat pump is: correct answers The lowest
temperature
which the heat at pump can meet the heating requirement for
the structure
$14.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
HopeJewels Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
70
Miembro desde
1 año
Número de seguidores
10
Documentos
8694
Última venta
1 semana hace
macellen education agencies

On this page, you find all documents,testsbank ,solution manuals, package deals, On this page, you find all documents, package deals, and flashcards offered by seller Hopejewels

3.2

5 reseñas

5
2
4
0
3
1
2
1
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes