What is the MOST important aspect about installing a rooftop package unit? correct answers The roof will support the weight What could be at fault of an air cooled system that operates 50°F over ambient temperature? correct answers An overcharge, air in the system, or air re-circulating over the condenser Where should the sensing bulb on a TXV be located? correct answers As close to the evaporator as possible on a horizontal line When a transformers secondary windings are wired in parallel, it is important to wire them ____________ correct answers In phase with each other If a single phase compressor is cycling on its overload protector, what should be checked? correct answers Voltage input, test capacitors, start relays, and motor windings. What is the maximum pressure drop across an R-404A suction line filter dryer? correct answers 2 PSI (2 degree saturation temp) What type of maintenance do water cooled condensers require? correct answers Clean the coil with scale remover and adjust the water valve If a CSR motor starts and operates with a high amperage, what could be at fault? correct answers A faulty run capacitor What causes excessive head pressure on water cooled condensers? correct answers Fouled condenser water, dirty water cooled condenser, over charge and air trapped in the condenser What happens during a hot pull down? correct answers The refrigeration system works hard and for low temperature systems a CPR (crankcase pressure regulator) is used to prevent compressor overloading What will ice on the ceiling and floor of a walk-in freezer typically indicate? correct answers A plugged drain line or a defective drain pan heater Name some ways to maintain head pressure during low ambient conditions correct answers Reduce the airflow over the condenser by a reverse acting high pressure switch, an electronic fan speed control, or louvers or use a head pressure control regulating valve (HPR) to back flood the condenser

Mostrar más Leer menos
Institución
NATE Light Commercial Refrigerati
Grado
NATE Light Commercial Refrigerati








Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NATE Light Commercial Refrigerati
Grado
NATE Light Commercial Refrigerati

Información del documento

Subido en
5 de noviembre de 2024
Número de páginas
2
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NATE Light Commercial Refrigeration
What is the MOST important aspect about installing a rooftop package
unit? correct
answers The roof will support the
weight
What could be at fault of an air cooled system that operates 50°F
over ambient correct answers An overcharge, air in the system, or air re-
temperature?
circulating
over the
condenser
Where should the sensing bulb on a TXV be located? correct answers As
close to theas possible on a
evaporator
horizontal line
When a transformers secondary windings are wired in parallel, it is
important to wire correct answers In phase with each
them
other
If a single phase compressor is cycling on its overload protector, what
should be correct answers Voltage input, test capacitors, start relays,
checked?
and motor
winding
s.
What is the maximum pressure drop across an R-404A suction line filter
dryer? correct
answers 2 PSI (2 degree saturation
temp)
What type of maintenance do water cooled condensers require? correct
answers
the Clean
coil with scale remover and adjust the
water valve
If a CSR motor starts and operates with a high amperage, what could
be at fault?
correct answers A faulty run
capacitor
What causes excessive head pressure on water cooled condensers? correct
answers
Fouled condenser water, dirty water cooled condenser, over charge and air
trapped in
the
condenser
What happens during a hot pull down? correct answers The refrigeration
system
hard andworks
for low temperature systems a CPR (crankcase pressure regulator)
is used to
prevent compressor
overloading
What will ice on the ceiling and floor of a walk-in freezer typically
indicate?Acorrect
answers plugged drain line or a defective drain pan
heater
Name some ways to maintain head pressure during low ambient
conditions
answers correct
Reduce the airflow over the condenser by a reverse acting high
pressure
switch, an electronic fan speed control, or louvers or use a head
pressure control
regulating valve (HPR) to back flood the
condenser
$13.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
HopeJewels Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
70
Miembro desde
1 año
Número de seguidores
10
Documentos
8694
Última venta
1 semana hace
macellen education agencies

On this page, you find all documents,testsbank ,solution manuals, package deals, On this page, you find all documents, package deals, and flashcards offered by seller Hopejewels

3.2

5 reseñas

5
2
4
0
3
1
2
1
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes