What are the ideal parameters for using ultrasound to treat a pressure ulcer? - Answers 3MHz, 0.5-1.0
W/cm^2, pulsed 20%
-Overall, the studies published so far indicate that pulsed ultrasound may facilitate wound healing, but
good evidence of this effect is lacking.
-The treatment parameters that have been found to be effective for this application are 20% duty cycle,
0.8-1.0 W/cm^2 intensity, 3 MHz frequency, for 5-10 minutes
What are the ideal treatment parameters for using ultrasound to treat pain via stimulation of cutaneous
thermal receptors? - Answers 3 MHz, 0.5 W/cm^2, continuous
-Only continuous ultrasound provides significant thermal effects to activate thermoreceptors, The
treatment parameters that have been found to be most effective for control of pain are continuous
ultrasound at 0.5-2.0 W/cm^2 intensity and 1.5 MHz freequency
Which of the following accurately describes the cause and effect relationship of ultrasound? - Answers
Increased frequency: decreased depth of penetration
-The correct answer is increased frequency: decreased depth of penetration because higher freqeucny
sound waves penetrate less deeply
Attenuation of ultrasound is caused by all of the following EXCEPT: - Answers Repulsion
-Attenuation is the result of absorption, reflection, and refraction with absorption accounting for about
50% of attenuation.
-Attenuation is greatest in tissues with high collagen content and with the use of high ultrasound
frequencies.
-Repulsiton is not a cause of ultrasound attenuation
What is the most common adverse effect of ultrasound? - Answers Burns
Although adverse effects are rare, the most common adverse effect is a burn.
-To minimize the risk of burning a patient, always move the ultrasound head and do not apply thermal-
level ultrasound to areas with impaired circulation or sensation.
-Reduce the ultrasound intensity in ares with superficial bone or if the patient complains of any increase
in discomfort
Which of the following statements is true given the same ultrasound intensity in all cases? - Answers 1
MHz will penetrate deeper than 3 MHz although temperature will be less