Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

IICL Container Inspector's Exam 1. Which of the following defects requires repair? A. A loose door gasket B. A bent J-bar that does not affect door operation C. A dent 13mm (1/2 in) deep on the door sill D. Four dents, each 11mm (7/16 in) deep,

Puntuación
-
Vendido
-
Páginas
18
Grado
A+
Subido en
29-10-2024
Escrito en
2024/2025

IICL Container Inspector's Exam 1. Which of the following defects requires repair? A. A loose door gasket B. A bent J-bar that does not affect door operation C. A dent 13mm (1/2 in) deep on the door sill D. Four dents, each 11mm (7/16 in) deep, on contiguous outboard corrugations of a roof panel: A. A loose door gasket

Mostrar más Leer menos
Institución
IICL
Grado
IICL

Vista previa del contenido

IICL Container Inspector's
Exam
1. Which of the following defects requires repairANS

A. A loose door gasket
B. A bent J-bar that does not affect door operation
C. A dent 13mm (1/2 in) deep on the door sill
D. Four dents, each 11mm (7/16 in) deep, on contiguous outboard corruga- tions of a roof panel: A. A loose door
gasket
2. Of the following conditions in a dry-van container, which one would require cleaningANS
A. Raised mud foot prints in excess of what might normally remain after a sweep out
B. Dry dust covering dried floor stains as might normally be found after a sweep out
C. Coffee beans remaining inside the container as might occur after a sweep out
D. Polyurethane beads as might be expected to lodge in grooves between floorboards after a sweep out: C.
Coffee beans remaining inside the container as might occur after a sweep out
3. An Equipment Interchange Receipt (EIR), based on an inspection with no damage found, can be evidence of a
container's compliance with: A. Australian Timber Component Treatment Regulations B. Convention for Safe
Containers (CSC) regulations through the ACEP Program
C. Transport under custom's seal (TIR) regulations D. International Standards Organization (ISO) CEDEX codes
regulations: B. Convention for Safe Containers (CSC) regulations through the ACEP Program
4. The top of a replacement plastic ventilator should be centered what distance from the top side railANS
A. 50-55mm (2-2 3/16 in) B. 70-75mm (2 5/8 - 3 in)
C. 100mm (4in) D. 150mm (6 in): A. 50-55mm (2-2 3/16 in)
5. When must a reference line extend the full length of a bottom side railANS
A. When there are two or more areas of damage on the bottom side rail B. When there is a sharp bend in the
bottom side rail
C. When there is a bowing over the entire bottom side rail D. When there is additional damage to the bottom
side rail so that the reference line cannot be positioned over the ends of the damage: C. When there is a bowing
over the entire bottom side rail
6. Which of the following is NOT a transverse structural member of the con- tainerANS
A. Front sill B. Tunnel rail
C. Rear header
D. Crossmember: B. Tunnel rail






, IICL Container Inspector's
Exam
7. A steel corner fitting is being replaced. To ensure better weld penetration, IICL recommends that the
edges of parts adjacent to the corner fitting be ground to a minimum bevel ofANS
A. 30 degrees B. 45 degrees
C. 55 degrees D. 60 degrees: B. 45 degrees
8. Which of the following components is sometimes placed longitudinally in the container to support
plywood flooringANS
A. Transverse bow B. Gusset
C. Hat section center spacer
D. Threshold plate: C. Hat section center spacer
9. Assuming owner and environmental regulations permit, which of the fol- lowing procedures is NOT
recommended for repairing tarpaulins or open top containersANS
A. Cleaning the area to be covered with acetone or mineral spirit
B. Using a heat gun to fuse a patch to the tarpaulin C. Sewing on a patch of the same material as the tarpaulin
D. Repairing a 6 mm (1/4 in ) pin hole with an epoxy compound: C. Sewing on a patch of the same material as the
tarpaulin
10. Which of the following is an example of a plank floor condition requiring repair AND which should be
considered as damageANS

A. A crack or split with no evidence of impact, which leaks light
B. A crack or split with a sign of impact which does not leak light
C. A crack or split, adjacent to a dented bottom rail, which leaks light
D. A crack or split, with no evidence of impact, with a loose piece: C. A crack or split, adjacent to a dented bottom
rail, which leaks light
11. Welds to corner fittings should be made withANS

A. CO2 semi-automatic welding
B. Low hydrogen welding rods
C. Fully automatic welding
D. Arc welding: B. Low hydrogen welding rods
12. All of the following procedures are required EXCEPT
A. Weld smoke, spatter, etc. must be removed to permit adhesion of paint
B. The damaged component(s) must be restored as close as possible to original size and profile
C. Welds must be examined using radiographic or magnetic particle non-de- structive testing equipment
D. Replacement steel components must be painted with coating compatible with that originally applied to
the container: C. Welds must be examined using radiographic or magnetic particle non-destructive testing
equipment
13. Where should the reference line be placed in order to determine repairwor- thiness of a crossmember flange
that is bent upwardsANS

A. Along the inside lower formed edge of the crossmember
B. Spaced out from the crossmember web




, IICL Container Inspector's
Exam
C. On the outermost flange surface along the full crossmember length
D. No measurement is necessary: D. No measurement is necessary
14. The damaged top rail X below is to be repaired by sectioning. Care must be taken to ensure that damage
area X is NOT cut less than a minimum of
A. 50mm (2 in)
B. 100mm (4 in)
C. 150mm (6 in)
D. 200mm (9 in): C. 150mm (6 in)
15. Rework of previously straightened panels is required when
A. evidence of considerable hammer marks is present
B. the owner's policy requires repair
C. the straightened area is an incorrect color
D. original profile of the corrugation is changed: B. the owner's policy requires repair
16. Door gaskets that are cut may be repaired by using cyanoacrylate adhe- sives to bond together the cut
edges of the gasket, PROVIDED
(I) No gasket material is missing
(II) The cut edges of the gasket mate together
(III) The cyanoacrylate adhesive will fill voids that exist at the joint

A. I only
B. I and II only
C. II and III only
D. I, II and III: (I) No gasket material is missing
(II) The cut edges of the gasket mate together

B. I and II only
17. With wooden flooring, height variance between adjacent planks or panels is limited to
A. 5 mm (3/16 in)
B. 10 mm (3/8 in)
C. 15 mm (9/16 in)
D. 20 mm (3/4 in): A. 5 mm (3/16 in)
18. In the Guide for Container Damage Measurement, IICL recommends a stan- dardized procedure using set
"reference dimensions" to determine if panel bows exceed ISO tolerances plus an additional IICL tolerance.
The reference dimension for an outward bow in a side panel is
A. 5 mm (3/16 in)
B. 10 mm (3/8 in)

Escuela, estudio y materia

Institución
IICL
Grado
IICL

Información del documento

Subido en
29 de octubre de 2024
Número de páginas
18
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$12.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
LectJordan Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
270
Miembro desde
4 año
Número de seguidores
239
Documentos
2719
Última venta
1 mes hace
One hour per day of study in your chosen field is all it takes. One hour per day of study will put you at the top of your field within three years.

NURSING, ECONOMICS, MATHEMATICS, BIOLOGY, AND ALL STUDY MATERIAL TUTORING, HOMEWORK HELP, EXAMS, TESTS, AND STUDY GUIDE MATERIALS WITH GUARANTEED A+ SUCCESS IN YOUR EXAMS!!!!!!!!!!!!!!

3.7

31 reseñas

5
11
4
6
3
10
2
2
1
2

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes