Surgical Technology Certification UPDATED ACTUAL Exam Questions and CORRECT Answers The surgeon asks that multiple suture and hernia mesh that were not on the preference card be opened during the repair of a large umbilical hernia. The surgical technologist should recognize that: a. items on the preference card are only to be changed by the surgeon or the unit clerk b. sterile supply associates who stock the hernia mesh are responsible for adding hernia mesh to the preference card c. preference card changes are unnecessary; both hernia mesh and suture are case dependent. d. suture may be case dependent, but the hernia mesh is integral to the procedure and should be added to the preference card - CORRECT ANSWER- Answer: D

Mostrar más Leer menos
Institución
Surgical Technology Certification
Grado
Surgical Technology Certification











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Surgical Technology Certification
Grado
Surgical Technology Certification

Información del documento

Subido en
21 de octubre de 2024
Número de páginas
50
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Surgical Technology Certification
UPDATED ACTUAL Exam Questions and
CORRECT Answers

The surgeon asks that multiple suture and hernia mesh that were not on the preference card be
opened during the repair of a large umbilical hernia. The surgical technologist should
recognize that:
a. items on the preference card are only to be changed by the surgeon or the unit clerk
b. sterile supply associates who stock the hernia mesh are responsible for adding hernia mesh
to the preference card
c. preference card changes are unnecessary; both hernia mesh and suture are case dependent.
d. suture may be case dependent, but the hernia mesh is integral to the procedure and should
be added to the preference card - CORRECT ANSWER- ✔✔Answer: D


Which of the following precautions should be taken by the surgical team when working with
polymethyl methacrylate as a bone cement?
a. wear latex free gloves, as polymethyl methacrylate interacts negatively with latex
b. remove contact lenses as polymethyl methacrylate can melt contact lenses and cause
corneal burns
c. make sure the patient does not have a latex allergy because polymethyl methacrylate and
latex have the same chemical properties
d. Limit the # of sponges on the field as polymethyl methacrylate can negatively interact with
the cotton fibers in the sponges. - CORRECT ANSWER- ✔✔Answer: B


Which of the following daily tests must be performed on the pre-vacuum sterilizer before
using it?
a. Gravity
b. Biological indicator
c. Bowie-Dick

d. Chemical indicator - CORRECT ANSWER- ✔✔Answer: C


What is the minimum exposure time in a flash sterilizer for unwrapped instruments?

,a. 1 minute
b. 3 minutes
c. 5 minutes

d. 7 minutes - CORRECT ANSWER- ✔✔Answer: B
[pre-vac] no lumen - 3 minutes ; lumen - 4 minutes


Which of the following is the correct temperature for the flash sterilizer operation?
a. 132*C (270*F)
b. 126*C (260*F)
c. 135*C (275*F)

d. 129*C (265*F) - CORRECT ANSWER- ✔✔Answer: A


Which of the following is the proper temperature and time that the chamber of a steam
sterilizer must reach in order to ensure that all spores have been eliminated?
a. 270*F for 4 minutes
b. 350*F for 4 minutes
c. 240*F for 10 minutes

d. 350*F for 10 mintues - CORRECT ANSWER- ✔✔Answer: A
[pre-vac] temp: 270*F ; time: 3-4 minutes ; pressure: 27 psi


The Sterrad sterilization system most commonly uses which of the following chemical
solutions?
a. hydrogen peroxide
b. gluteraldehyde
c. alcohol

d. peracetic acid - CORRECT ANSWER- ✔✔Answer: A
[Sterrad] make sure its plugged in - needs electricity


Which of the following is used to achieve high level disinfection with a minimum exposure
time of 20-45 minutes?
a. chlorine bleach compounds

,b. gluteraldehyde
c. hydrogen peroxide

d. iodine and iodophors - CORRECT ANSWER- ✔✔Answer: B


During decontamination of a flexible endoscope, which of the following tests should be given
to inspect the proper function of the endoscope and to ensure that it can be properly
sterilized?
a. leak test
b. electrical component test
c. bacteria swab test

d. fiber optic light test - CORRECT ANSWER- ✔✔Answer: A


Which of the following is the fastest method of sterilization?
a. gas
b. steam
c. steris

d. dry heat - CORRECT ANSWER- ✔✔Answer: B


Which of the following is the correct temperature for pre-vacuum sterilization?
a. 212*F
b. 170*F
c. 300*F

d. 270*F - CORRECT ANSWER- ✔✔Answer: D


Which of the following tests is specifically meant to test and monitor the efficiency of the
high - vacuum steam sterilizer?
a. biological indicator test
b. DART test
c. chemical indicator test

d. EtO test - CORRECT ANSWER- ✔✔Answer: B
DART test = Bowie Dick test

, The surgical team must verify each package is properly labeled with
a. date of processing and method of sterilization
b. date of processing and indicator
c. method of sterilization and expiration date

d. indicator and expiration date - CORRECT ANSWER- ✔✔Answer: B


How many times a day should a DART test be preformed?
a. with every load
b. every shift change
c. once every 24 hours

d. weekly - CORRECT ANSWER- ✔✔Answer: C


How often must a biological control test be run?
a. every day
b. every cycle
c. once a week

d. once a month - CORRECT ANSWER- ✔✔Answer: A
[pg. 163]


The Bowie-Dick test for pre-vacuum sterilizers checks for which of the following conditions?
a. that the appropriate steam level was reached
b. air leaks in the sterilizer chamber
c. broken sterilizer jacket

d. that the sterilizer is ready to process instruments - CORRECT ANSWER- ✔✔Answer: B


lot control numbers should be placed on each package sterilized and on the...
a. sterilizer maintenance record
b. sterilization load record
c. nursing documentation
$10.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MGRADES Stanford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1072
Miembro desde
1 año
Número de seguidores
102
Documentos
68976
Última venta
1 día hace
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

170 reseñas

5
73
4
30
3
45
2
8
1
14

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes