Technician Exam
Questions With Revised
Correct Detailed Answers
|ALREADY GRADED A+ PASS
>> BRAND NEW VERSION!
1) What are the components of the Fire Triangle?
Fuel, Heat/Ignition Source, Oxygen
2) If equipped with an over fill alarm, it must be located?
So it can be seen or heard from the delivery location.
If installed, the following requires independent 3rd party
certification to prove compliance with established regulations.
3) Where are ATG's installed?
Opening in top of the tank
4) What is true about ATG's
They're capable of alarming operator of low product level
5) The following types of releases must be reported to the
local agency.
,Releases greater than 25 gallons that escape secondary
containment. Release that escape primary containment.
Releases less than 25 gallons which escape secondary
containment
6) If an unauthorized product release meets the
requirements for reporting to the local agency, verbal
notification must be made within ____hours, followed by a
written notification within ____days.
24 HRS, 5 DAYS
7) The following unusual conditions shall be reported to the
local agency, EXCEPT:
Water in spill buckets
8) If the monitoring system detects a leak that has occurred,
the local agency must be notified unless______.
Unless the monitoring device is found to be defective and is
immediately repaired.
9) The written report submitted to the local agency after an
unauthorized release is required to include the following
EXCEPT:
Cause of release
10) An unauthorized release which does not escape
secondary containment, requires only recordation on the
Operators Manual Report provided if what criteria is met?
,It did not cause deterioration of secondary containment. It did
not increase the hazard of fire. It was cleaned up within eight
hours and it was cleaned up within eight hours detection.
11) Recording of an authorized release in the operators
monitoring records shall include?
Actions taken to prevent further releases.
12) If a authorized release meets reporting requirements
of Title 23, section 2652, the report must be filed within
the? (Un or A?)
Local agency
13) Which statement concerning the annual monitor
certification is most correct?
Local agencies must be notified 48 hours prior to certification in
results must be submitted within 30 days of certification.
14) The annual monitor certification may be performed
by?
A person possessing the appropriate contractor's license. An
individual trained and certified by the manufacture of the
monitoring equipment.
15) The following is true of secondary containment
EXCEPT:
Must be tested every 24 months.
, 16) Enhanced the detections results must be submitted
to ___ within ___days
the local agency and state water resources control board within
60 days.
The EPA recommends that monthly the operator should
conduct a walk-through inspection of the following EXCEPT: the
operator should conduct a monthly walk-through inspection...
or is this a DO walk thorough?- the monthly DO should conduct
a walk-through inspection...
Facility lighting
Cathodic protection systems must be tested within
____months of installation and every ____months thereafter.
tested within 6 months of installation and every 36 months
thereafter.
Impressed current catholic protection systems shall be
inspected no less then every___?
30 days
The EPA suggested list of supplies for spill containment and
clean up include all the following EXCEPT:
Wet dry shop vacuum
According to the Health and Safety Code, the owner of a new
tank must conduct a one-time ELD test if the tank is located
within 1000 ft. of a public drinking water well. This test must
accomplish by? When was did this become required?