NHIE Electrical Part 1 Questions and Answers What is the danger of a fused neutral? - Answer-Circuit remains hot if fixture stops working. What is the ampacity of copper #8? - Answer-40 amps. What is the minimum service required for new single family houses? - Answer-100 amps. What is the appropriate breaker for a 30 amp appliance? - Answer-30 amp breaker. What is the issue with aluminum wire? - Answer-Prone to differential expansion with copper wire. What outlets can aluminum wire be terminated with? - Answer-Outlets labeled 'CO/ALR' or 'CU/AL'. What is the equivalent of 1 kilowatt? - Answer-3412 BTUs. How should wiring for attic fans be run? - Answer-Through rafters or alongside rafters with splices in junction boxes. How often should outlets be placed on a kitchen counter top? - Answer-Every 24 inches. When are three-way switches required? - Answer-On stairways with four or more risers. What is the ampacity of #10 copper wire? - Answer-30 amps. EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 2/6 What should be done if a receptacle is warm to the touch? - Answer-Inform homeowner, suggest electrician, report condition. What is the clearance requirement for a residential overhead service? - Answer-At least 10 feet above where vehicles pass underneath. What is the clearance requirement for an electrical service above a flat roof? - Answer-At least 8 feet above a flat roof, 10 feet if used as a walking surface. What is the size difference between aluminum and copper wire to carry the same ampacity? - Answer-Aluminum must be one size larger. What are some required GFCI locations? - Answer-Whirlpool tubs, kitchens, bathrooms, garage, swimming pools, hot tubs, boat houses, exterior outlets. What is the only over current protection an inspector is required to test or operate? - Answer-GFCIs. What receptacles must an inspector test the polarity and grounding of? - Answer-All within 6 feet of interior plumbing fixtures, all in garage or carport, all on exterior of structure. What is the maximum number of throws to disconnec

Mostrar más Leer menos
Institución
2024/2025
Grado
2024/2025









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
2024/2025
Grado
2024/2025

Información del documento

Subido en
16 de octubre de 2024
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024




NHIE Electrical Part 1 Questions and Answers


What is the danger of a fused neutral? - Answer✔✔-Circuit remains hot if fixture stops working.


What is the ampacity of copper #8? - Answer✔✔-40 amps.


What is the minimum service required for new single family houses? - Answer✔✔-100 amps.


What is the appropriate breaker for a 30 amp appliance? - Answer✔✔-30 amp breaker.


What is the issue with aluminum wire? - Answer✔✔-Prone to differential expansion with

copper wire.


What outlets can aluminum wire be terminated with? - Answer✔✔-Outlets labeled 'CO/ALR' or

'CU/AL'.


What is the equivalent of 1 kilowatt? - Answer✔✔-3412 BTUs.


How should wiring for attic fans be run? - Answer✔✔-Through rafters or alongside rafters with

splices in junction boxes.


How often should outlets be placed on a kitchen counter top? - Answer✔✔-Every 24 inches.


When are three-way switches required? - Answer✔✔-On stairways with four or more risers.


What is the ampacity of #10 copper wire? - Answer✔✔-30 amps.




Page 1/6

, EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


What should be done if a receptacle is warm to the touch? - Answer✔✔-Inform homeowner,

suggest electrician, report condition.


What is the clearance requirement for a residential overhead service? - Answer✔✔-At least 10

feet above where vehicles pass underneath.


What is the clearance requirement for an electrical service above a flat roof? - Answer✔✔-At

least 8 feet above a flat roof, 10 feet if used as a walking surface.


What is the size difference between aluminum and copper wire to carry the same ampacity? -

Answer✔✔-Aluminum must be one size larger.


What are some required GFCI locations? - Answer✔✔-Whirlpool tubs, kitchens, bathrooms,

garage, swimming pools, hot tubs, boat houses, exterior outlets.


What is the only over current protection an inspector is required to test or operate? -

Answer✔✔-GFCIs.


What receptacles must an inspector test the polarity and grounding of? - Answer✔✔-All within

6 feet of interior plumbing fixtures, all in garage or carport, all on exterior of structure.


What is the maximum number of throws to disconnect all power to the house? - Answer✔✔-Six


What is the correct amperage for an air conditioner breaker? - Answer✔✔-40 amps


What does two wires entering a service weather head indicate? - Answer✔✔-110 volt system




Page 2/6
$10.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Emillect West Virginia University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
28
Miembro desde
1 año
Número de seguidores
2
Documentos
3004
Última venta
2 meses hace
GOLDEN ORCHIDS STORE.

On this page, you find all documents, package deals, and flashcards offered by seller Emillect.

3.0

4 reseñas

5
1
4
0
3
2
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes