Fluoroscopy exam Questions and Answers- Updated 2024 Total filtration permanently required in the useful fluoroscopic beam should not be less than - Answer-2.5mm Aluminum If X-ray source is below the table, useful beam exposure must be measured at what distance above the table top - Answer-30 cm Table top exposure rates for units without auto exposure control must be measured every - Answer-3 years Dark adaptation for the eye takes how long - Answer-30 minutes Target-to-tabletop distance must be greater than and should be greater than... - Answer-12 and 18 inches Integration time for brain to recognize an object - Answer-0.2 seconds Most scatter occurs at which direction from the primary beam - Answer-135 degrees mA setting for spot filming where a spot film camera is not used - Answer-150 mA Greatest dose to the patient comes from spot filming cameras using this film size - Answer- 105 mm EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 2/16 SI unit analogous to the rad is - Answer-Gray _________ is a variation in density resulting from the random spatial distribution of quanta. - Answer-Quantum sink SI unit analogous to the rem - Answer-Sievert (unit) Exposure reduction of .25 mm lead - Answer-97% Scattered radiation received is proportional to - Answer-Dose received by the patient Most effective medium for static viewing in terms of reducing patient dose - Answer-Video disc recorder Contrast of the image intensifying tube is measured by - Answer-conversion factor maximum magnification for cinefluorography is done via which method - Answer-total over framing Ratio of photons that leave the output phosphor to the number of Xray photons that strike the input phosphor - Answer-Flux gain Half value layer determines which characteristic of the Xray - Answer-Xray quality Ability to distinguish separate objects in line pairs per mm - Answer-Resolving power The portion of the image intensifier responsible for magnification - Answer-electrostatic lenses resolution of a 9 inch image intensifier tube - Answer-3.5 line pairs per millimeter EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 3/16 light photons intercepting when electrons strike a fluorescent screen forms a... - Answer- Real image Fluoro with a grid in place affects exposure rates how - Answer-1.5-2 x higher Greatest radiosensitivity of fetus occurs when - Answer-2-8 weeks gestation The quantity of the beam is controlled by which unit of measurement - Answer- miliamperage Which fluoroscopic method gives patient dose reduction of up to to 95%? - Answer-video disc recorder 100erg/gram is equivalent to? - Answer-1 rad Fluoro units with AECs or CINE cameras must have physicist calibration how often - Answer- every year Which imaging modality has the best resolution - Answer-Radiograph Compared to the input phosphor, the image output phosphor is... - Answer-Smaller and brighter As spot film size increases, what happens to the patient dose? - Answer-Patient dose increases Unit used to specify the quality of an X-ray beam - Answer-HVL

Mostrar más Leer menos
Institución
Fluoroscopy
Grado
Fluoroscopy










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Fluoroscopy
Grado
Fluoroscopy

Información del documento

Subido en
16 de octubre de 2024
Número de páginas
16
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024




Fluoroscopy exam Questions and
Answers- Updated 2024

Total filtration permanently required in the useful fluoroscopic beam should not be less than -

Answer✔✔-2.5mm Aluminum


If X-ray source is below the table, useful beam exposure must be measured at what distance

above the table top - Answer✔✔-30 cm


Table top exposure rates for units without auto exposure control must be measured every -

Answer✔✔-3 years


Dark adaptation for the eye takes how long - Answer✔✔-30 minutes


Target-to-tabletop distance must be greater than and should be greater than... - Answer✔✔-12

and 18 inches


Integration time for brain to recognize an object - Answer✔✔-0.2 seconds


Most scatter occurs at which direction from the primary beam - Answer✔✔-135 degrees


mA setting for spot filming where a spot film camera is not used - Answer✔✔-150 mA


Greatest dose to the patient comes from spot filming cameras using this film size - Answer✔✔-

105 mm


Page 1/16

,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


SI unit analogous to the rad is - Answer✔✔-Gray


_________ is a variation in density resulting from the random spatial distribution of quanta. -

Answer✔✔-Quantum sink


SI unit analogous to the rem - Answer✔✔-Sievert (unit)


Exposure reduction of .25 mm lead - Answer✔✔-97%


Scattered radiation received is proportional to - Answer✔✔-Dose received by the patient


Most effective medium for static viewing in terms of reducing patient dose - Answer✔✔-Video

disc recorder


Contrast of the image intensifying tube is measured by - Answer✔✔-conversion factor


maximum magnification for cinefluorography is done via which method - Answer✔✔-total over

framing


Ratio of photons that leave the output phosphor to the number of Xray photons that strike the

input phosphor - Answer✔✔-Flux gain


Half value layer determines which characteristic of the Xray - Answer✔✔-Xray quality


Ability to distinguish separate objects in line pairs per mm - Answer✔✔-Resolving power


The portion of the image intensifier responsible for magnification - Answer✔✔-electrostatic

lenses


resolution of a 9 inch image intensifier tube - Answer✔✔-3.5 line pairs per millimeter

Page 2/16

, EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


light photons intercepting when electrons strike a fluorescent screen forms a... - Answer✔✔-

Real image


Fluoro with a grid in place affects exposure rates how - Answer✔✔-1.5-2 x higher


Greatest radiosensitivity of fetus occurs when - Answer✔✔-2-8 weeks gestation


The quantity of the beam is controlled by which unit of measurement - Answer✔✔-

miliamperage


Which fluoroscopic method gives patient dose reduction of up to to 95%? - Answer✔✔-video

disc recorder


100erg/gram is equivalent to? - Answer✔✔-1 rad


Fluoro units with AECs or CINE cameras must have physicist calibration how often - Answer✔✔-

every year


Which imaging modality has the best resolution - Answer✔✔-Radiograph


Compared to the input phosphor, the image output phosphor is... - Answer✔✔-Smaller and

brighter


As spot film size increases, what happens to the patient dose? - Answer✔✔-Patient dose

increases


Unit used to specify the quality of an X-ray beam - Answer✔✔-HVL


cycles per time unit in a TV camera is known as... - Answer✔✔-bandwidth

Page 3/16
$10.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Emillect West Virginia University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
28
Miembro desde
1 año
Número de seguidores
2
Documentos
3004
Última venta
1 mes hace
GOLDEN ORCHIDS STORE.

On this page, you find all documents, package deals, and flashcards offered by seller Emillect.

3.0

4 reseñas

5
1
4
0
3
2
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes