Which components make up the Primary system? Answer - LD PWB, Lens and
Polygon mirror
The Fusing Belt Meandering Adjustment must be performed for the following
cases. Answer - 1. When you replace parts in the Fusing Unit
2. If SIM 6-8 results other than OK
Which Sensor detects when there is paper in Paper Feed Tray 2? Answer -
C2PED
Which sensor detects movement of the fusing belt? Answer - FBMD
True or False: The LED DRV PWB illuminates the document with light so the
CCD PWB can read it. Answer - False
If the transfer roller loses the transfer bias voltage, what symptoms might you
observe? Answer - Blank or faint images on copies
The HV MC PWB interfaces with which PWB(s)? Answer - PCU PWB
What symptoms might you observe if the OPC drum cleaning blade failed to
clean the surface of the drum correctly? Answer - 1. Dark or dirty background
on copies