100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

MASSACHUSETTS OIL BURNER EXAM | QUESTIONS AND CORRECT ANSWERS | GRADED A+ | LATEST EXAM | VERIFIED ANSWERS | JUST RELEASED

Puntuación
-
Vendido
-
Páginas
78
Grado
A+
Subido en
12-10-2024
Escrito en
2024/2025

MASSACHUSETTS OIL BURNER EXAM | QUESTIONS AND CORRECT ANSWERS | GRADED A+ | LATEST EXAM | VERIFIED ANSWERS | JUST RELEASED

Institución
MASSACHUSETTS OIL BURNER
Grado
MASSACHUSETTS OIL BURNER











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
MASSACHUSETTS OIL BURNER
Grado
MASSACHUSETTS OIL BURNER

Información del documento

Subido en
12 de octubre de 2024
Número de páginas
78
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

MASSACHUSETTS OIL BURNER EXAM |
QUESTIONS AND CORRECT ANSWERS
| GRADED A+ | LATEST EXAM |
VERIFIED ANSWERS | JUST RELEASED

What must be done to install an additional fuel tank in a building that
already has a tank holding 1320 gallons ---------CORRECT ANSWER--------
---------They must have a firewall around them



What must be done with the bypass plug on a two pipe system and on a
one pipe system ---------CORRECT ANSWER-----------------On a one pipe
system. the bypass plug must be removed .on a two pipe system the
bypass must be installed.



What is a bypass plug ---------CORRECT ANSWER-----------------A 1/16 inch
plug to convert 1 pipe to a 2 pipe system



What is a power burner ---------CORRECT ANSWER-----------------Anything
that's not a vaporizing oil burner



Can a series 10 .3 wire thermostat be used with a 2-wire control? explain. -
--------CORRECT ANSWER-----------------Yes by jumping out the ground



Can a series 80 dryer thermostat be wired into a 3-wire control ---------
CORRECT ANSWER-----------------No

,What is the greatest loss in a boiler ---------CORRECT ANSWER--------------
---Heat loss through the chimney



How high on the wall should thermostat be installed ---------CORRECT
ANSWER-----------------5 feet from the ground



What must be checked while installing a Mercury bulb thermostat ---------
CORRECT ANSWER-----------------Must be checked to be level



Why are low voltage thermostats use more than line voltage ones ---------
CORRECT ANSWER-----------------Safety



What additional requirements are there for installing two or more tanks to a
common discharge line ---------CORRECT ANSWER-----------------They
must be on a common slab at the same height and secure to one another



6 oil burners have been installed in a large room which is of tight
construction and which must be kept closed at all times there is decidedly
not enough combustion air for proper burner operation there burner sizes
are 1.35 gallons per hour under these conditions what is the minimum free
area of an opening connecting to the outdoors which must be provided -----
----CORRECT ANSWER-----------------567 inch by 2 inch vent going to
outside



what is the maximum voltage allowed for an oil burner circuit ---------
CORRECT ANSWER-----------------150 volts

,Is carbon monoxide a desirable element in flue gases ---------CORRECT
ANSWER-----------------No



How much air is needed to burn a gallon of fuel oil and why ---------
CORRECT ANSWER-----------------14.4 plus 50% 192 feet cubed 154 CF to
ensure enough oxygen



When visually adjusting the flame on an oil burner you should try to get -----
----CORRECT ANSWER-----------------An orange flame with red Flame tips



Explain how a burner should be piped when the supply tank is located
below the burner ---------CORRECT ANSWER-----------------2. Pipe dual
stage with a bypass plug



How should a stack switch be installed according to 527 CMR 4.00 ---------
CORRECT ANSWER-----------------With a flexible conduit



Why should a stack switch not be rigidly mounted ---------CORRECT
ANSWER-----------------So you can pull it out and check it



When Shall steam heating boiler and a hot water boiler require inspection
by the commissioner of mass Dept of Public Safety before it is put into
service ---------CORRECT ANSWER-----------------Any time a permit is
pulled to install or alter a burner

, Where is the check valve installed on a two pipe system when there is a lift
situation ---------CORRECT ANSWER-----------------As close to the tank as
possible supply-side



How many seconds must have primary safety control shut off the burner ---
------CORRECT ANSWER-----------------Firing Less Than 3 gallons per hour
45 seconds firing 3 - 7 gallons per hour 15 seconds



What is normal pump pressure ---------CORRECT ANSWER-----------------
100 PSI



What would be the advantages of a pump pressure higher than 100 PSI ----
-----CORRECT ANSWER-----------------A cleaner burn



What determines the size of a nozzle gallons per hour ---------CORRECT
ANSWER-----------------The maximum firing rate



What is the purpose of a draft regulator ---------CORRECT ANSWER---------
--------To get the proper amount of air flow through the burner



What are two ways to adjust draft ---------CORRECT ANSWER-----------------
Primary and secondary air ,and the draft regulator
$26.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
nevilletadayo Capella University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
845
Miembro desde
2 año
Número de seguidores
457
Documentos
3250
Última venta
11 horas hace
INVEST IN YOUR FUTURE EXCELLENCE TODAY!

Unlock Your Academic Success: Gain Access to Expertly Crafted Exams, Flash Cards, Test Banks, and Study Guides on this Premium Stuvia Account. Elevate Your Learning Experience and Achieve Top Grades with our Comprehensive and Time-Saving Resources.

4.6

318 reseñas

5
249
4
37
3
15
2
6
1
11

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes