NICET Level 1 Questions with Correct Answers The operable part of a manually actuated alarm initiating device shall be not less than ____ inches AFF? - Answer-42 Consider the use of grounding electrodes. Rod and pipe electrodes shall not be less than____ feet in length? - Answer-8 Smoke detectors should not be located in a direct airflow or closer than ____ inches from an air supply diffuser or return air opening? - Answer-36 Consider the use of visible notification appliances. Wall mounted appliances shall be mounted such that the entire lens is not less than ____ inches above the finished floor? - Answer-80 How many 16 gauge conductors are permitted in a 4 x 1 1/2 inches square box? - Answer-12 Wall mounted audible appliances shall have their tops above the finished floors at heights of not less than ____ inches and below the finished ceilings at distances of not less than 6 inches? - Answer-90 A minimum ____ db ambient sound level with a 6 hour exposure time requires hearing protection? - Answer-92 Spot type heat sensing fire detectors shall be located on the ceiling not less than ____ inches from the sidewall. - Answer-4 EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED FIRST PUBLISH SEPTEMBER 2024 Page 2/7 While operating an aerial lift, the use of a body harnes and ____ is not required? - Answer-Stabilizer Hook, Grounding Pole, Insulation Mat Spot type smoke detectors shall be located on the ceiling or, if on a sidewall, between the ceiling and ____ inches down from the ceiling to the top of the detector. - Answer-12 The distance between spot type heat detectors shall not exceed their listed spacing, and there shall be detectors within a distance of ____ the listed spacing, measured at right angles from the walls? - Answer-One Half Where partitions extend to within ____ percent of the ceiling height, the spaces separated by the partitions shall be considered as separate rooms? - Answer-15 Consider 1,000 feet total of 18 gauge soild coated copper at 167o Fahrenheit. The resistance of this conductor is ____ ohm? - Answer-8.08 Consider the installation of heat detectors on a ceiling with beams. A ceiling shall be treated as a smooth ceiling if the beams project no more than____ inches below the ceiling? - Answer-4 Which of the following conductor types is an acceptable substitute for FPLR? - Answer-FPLP, CMP Consider the use of PLFA fire alarm cable. The size of conductors in

Mostrar más Leer menos
Institución
Nicet
Grado
Nicet









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Nicet
Grado
Nicet

Información del documento

Subido en
6 de octubre de 2024
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024




NICET Level 1 Questions with Correct
Answers

The operable part of a manually actuated alarm initiating device shall be not less than ____ inches AFF?

- Answer✔✔-42


Consider the use of grounding electrodes. Rod and pipe electrodes shall not be less than____ feet in

length? - Answer✔✔-8


Smoke detectors should not be located in a direct airflow or closer than ____ inches from an air supply

diffuser or return air opening? - Answer✔✔-36


Consider the use of visible notification appliances. Wall mounted appliances shall be mounted such that

the entire lens is not less than ____ inches above the finished floor? - Answer✔✔-80


How many 16 gauge conductors are permitted in a 4 x 1 1/2 inches square box? - Answer✔✔-12


Wall mounted audible appliances shall have their tops above the finished floors at heights of not less

than ____ inches and below the finished ceilings at distances of not less than 6 inches? - Answer✔✔-90


A minimum ____ db ambient sound level with a 6 hour exposure time requires hearing protection? -

Answer✔✔-92


Spot type heat sensing fire detectors shall be located on the ceiling not less than ____ inches from the

sidewall. - Answer✔✔-4




Page 1/7

, EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024


While operating an aerial lift, the use of a body harnes and ____ is not required? - Answer✔✔-Stabilizer

Hook, Grounding Pole, Insulation Mat


Spot type smoke detectors shall be located on the ceiling or, if on a sidewall, between the ceiling and

____ inches down from the ceiling to the top of the detector. - Answer✔✔-12


The distance between spot type heat detectors shall not exceed their listed spacing, and there shall be

detectors within a distance of ____ the listed spacing, measured at right angles from the walls? -

Answer✔✔-One Half


Where partitions extend to within ____ percent of the ceiling height, the spaces separated by the

partitions shall be considered as separate rooms? - Answer✔✔-15


Consider 1,000 feet total of 18 gauge soild coated copper at 167o Fahrenheit. The resistance of this

conductor is ____ ohm? - Answer✔✔-8.08


Consider the installation of heat detectors on a ceiling with beams. A ceiling shall be treated as a smooth

ceiling if the beams project no more than____ inches below the ceiling? - Answer✔✔-4


Which of the following conductor types is an acceptable substitute for FPLR? - Answer✔✔-FPLP, CMP


Consider the use of PLFA fire alarm cable. The size of conductors in multiconductor cable shall not be

smaller than____ AWG? - Answer✔✔-26


You are using a power tool that has a 3 prong (grounded) plug. The only outlets available are 2 prong

(non grounded). What can be done? - Answer✔✔-Locate a 3 prong plug or used a tool with a 2 prong

plug.




Page 2/7
$9.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EmillyCharlotte Howard Community College
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
94
Miembro desde
1 año
Número de seguidores
4
Documentos
11951
Última venta
2 días hace
ALL-MAJOR.

On this page, you find all documents, package deals, and flashcards offered by seller Emilly Charlotte.

3.6

20 reseñas

5
7
4
6
3
2
2
2
1
3

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes