2024/2025

EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED FIRST PUBLISH SEPTEMBER 2024 Page 3/10 Gauges on a dry, preaction system, and deluge systems shall be inspected? - Answer-Monthly When the gauge near the compressor is reading higher than the gauge near the dry pipe valve, the air line shall be what? - Answer-Taken out of service Waterflow alarm and supervisory alarm devices shall be inspected? - Answer-Quarterly The hydraulic design information sign for hydraulically designed systems shall be inspected? - Answer-Quarterly The information sign shall be inspected? - Answer-Annually, Where sprinklers have been on service for 50 years shall be? - Answer-Replaced Sprinklers manufactured prior to 1920 shall be? - Answer-Replaced Sprinklers manufactured using fast-response elements that have been in service for 20 years shall be? - Answer-Replaced or tested at 10 year intervals Representative samples of solder-type sprinklers with a temperature classification of extra high (325*F) or greater that are exposed to semi continuous to continuous maximum allowable ambient temperature conditions shall be? - Answer-Tested at 5 year intervals Dry sprinklers that have been in service for 10 years shall be? - Answer-Tested Where sprinklers are subjected to harsh environments, including corrosive atmospheres and corrosive water supplies, on a five years basis shall be? - Answer-replaced or representative sprinkler samples shall be tested, Gauges shall be replaced every? - Answer-5 years EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED FIRST PUBLISH SEPTEMBER 2024 Page 4/10 Gauges not accurate within 3 percent of the full scale shall be? - Answer-Recalibrated or replaced Mechanical waterflow alarm devices including, but not limited to, water motor gongs shall be tested? - Answer-Quarterly Vane-Type and pressure-type waterflow alarm devices shall be tested? - Answer-Semi-annually Testing waterflow alarm devices on a dry pipe, preaction, or deluge system shall be accomplished by? - Answer-Using the bypass connection For protected facilities having under 300 sprinklers there should be ho

Mostrar más Leer menos
Institución
Nicet
Grado
Nicet









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Nicet
Grado
Nicet

Información del documento

Subido en
6 de octubre de 2024
Número de páginas
10
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024




NICET Level 1 ITM Of Water-Based
Systems Exam Practice Questions and
Answers |100% Pass

Who is responsible for the inspection, testing, maintenance and impairment of a water based fire

protection system? - Answer✔✔-The Property owner or designated representative


Who's responsibility is it to provide accessibility to components of a water based fire protection system?

- Answer✔✔-The property owner or designated representative


Who shall correct or repair deficiencies or impairments found during the inspection, test and

maintenance required by standard? - Answer✔✔-The property owner or designated representative


Who is qualified to preform the corrections and repairs of a water based fire protection system? -

Answer✔✔-Qualified maintenance personal or a qualified contractor


A permanently marked metal or rigid plastic information sign shall be placed at the system control riser

supplying an antifreeze loop, dry system, preaction, or auxiliary system control valve? - Answer✔✔-An

Information Sign,


Records made during all inspections, tests and maintenance shall be made available to who upon

request? - Answer✔✔-The Authority Having Jurisdiction


All records shall be maintained by? - Answer✔✔-The Property Owner


How long should subsequent records be retained? - Answer✔✔-1 year,


Page 1/10

, EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024


After the testing and reinstallation of plugs and caps for auxiliary drain and test valves, what action is

required? - Answer✔✔-Shall be restored to full operational condition,


To avoid false alarms where a supervisory service is provided the alarm receiving facility shall be notified

by the property owner or designated representative before? - Answer✔✔-conducting any test or

procedure that could result in the activation of an alarm,


Sprinklers shall be inspected when and how? - Answer✔✔-Shall be inspected from the floor level

annually


Sprinklers shall not show signs of the following? - Answer✔✔-leakage; shall be free of corrosion, foreign

materials, paint, and physical damage; and shall be installed in the correct orientation


Sprinklers installed installed in concealed spaces such as above ceilings shall what? - Answer✔✔-Shall

not require inspection,


Sprinklers installed in areas that are inaccessible for safety considerations due to process operations shall

be inspected? - Answer✔✔-During each scheduled shutdown


The supply of spare sprinklers shall be inspected when? - Answer✔✔-Annually,


A spare sprinkler wrench shall be required for what? - Answer✔✔-Every type of sprinkler,


Sprinkler pipe and fittings shall be inspected from where and when? - Answer✔✔-Annually from from

the floor level,


Sprinkler Pipe hangers and seismic bracing shall be inspected? - Answer✔✔-Annually from the floor level


Gauges on a wet pipe sprinkler system shall be inspected? - Answer✔✔-Monthly,


Page 2/10
$9.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EmillyCharlotte Howard Community College
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
94
Miembro desde
1 año
Número de seguidores
4
Documentos
11951
Última venta
2 días hace
ALL-MAJOR.

On this page, you find all documents, package deals, and flashcards offered by seller Emilly Charlotte.

3.6

20 reseñas

5
7
4
6
3
2
2
2
1
3

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes