NICET LEVEL 1 EXAM QUESTIONS AND ANSWERS |100% PASS 4 wires - Answer-what is the maximum number of 14 AWG RHH conductors which can be installed in 1/2 rigid metal conduit? 3.5'-48" to the actuator - Answer-Which of the following would be an appropriate mounting height for a pull station? 1 flash per second - Answer-What is the minimum flash rate for a visible notification device? 90" to the top of the device - Answer-What is the minimum mounting height for audible notification devices? Such that the entire lens is not less then 80" - Answer-What is the minimum mounting height for visible notification devices? Voltage=Current X Resistence - Answer-What is the formula for Ohm's Law Put your meter in series with the circuit - Answer-When using your mult-meter to measure, you must: Semi-annually - Answer-Waterflow devices shall be tested with that frequency? Annually - Answer-With what frequency shall ionization smoke detectors be given a functional test? EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED FIRST PUBLISH SEPTEMBER 2024 Page 2/9 24 hours in normal operation, 5 minutes in alarm - Answer-What are the standby power requirements for a proprietary signaling system? Shunt type - Answer-Which of the following is a type of auxiliary protective signaling system? A UL listed central station A receiver located at an unlisted monitoring facility A fire department or communications center - Answer-Remote station signaling systems are permitted to send signals to: 600V - Answer-Non-power limited fire alarm cable shall have an insulation rating of: 20,000 CFM HVAC system serving a single floor 15,000 CFM HVAC system serving 3 floors 20,000 CFM HVAC system serving 2 floors - Answer-Which of

Mostrar más Leer menos
Institución
Nicet
Grado
Nicet









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Nicet
Grado
Nicet

Información del documento

Subido en
6 de octubre de 2024
Número de páginas
9
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024




NICET LEVEL 1 EXAM QUESTIONS
AND ANSWERS |100% PASS

4 wires - Answer✔✔-what is the maximum number of 14 AWG RHH conductors which can be installed in

1/2 rigid metal conduit?


3.5'-48" to the actuator - Answer✔✔-Which of the following would be an appropriate mounting height

for a pull station?


1 flash per second - Answer✔✔-What is the minimum flash rate for a visible notification device?


90" to the top of the device - Answer✔✔-What is the minimum mounting height for audible notification

devices?


Such that the entire lens is not less then 80" - Answer✔✔-What is the minimum mounting height for

visible notification devices?


Voltage=Current X Resistence - Answer✔✔-What is the formula for Ohm's Law


Put your meter in series with the circuit - Answer✔✔-When using your mult-meter to measure, you

must:


Semi-annually - Answer✔✔-Waterflow devices shall be tested with that frequency?


Annually - Answer✔✔-With what frequency shall ionization smoke detectors be given a functional test?




Page 1/9

, EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024


24 hours in normal operation, 5 minutes in alarm - Answer✔✔-What are the standby power

requirements for a proprietary signaling system?


Shunt type - Answer✔✔-Which of the following is a type of auxiliary protective signaling system?


A UL listed central station


A receiver located at an unlisted monitoring facility


A fire department or communications center - Answer✔✔-Remote station signaling systems are

permitted to send signals to:


600V - Answer✔✔-Non-power limited fire alarm cable shall have an insulation rating of:


20,000 CFM HVAC system serving a single floor


15,000 CFM HVAC system serving 3 floors


20,000 CFM HVAC system serving 2 floors - Answer✔✔-Which of these HVAC systems would require duct

detectors on supply and return?


Group A, E, F - Answer✔✔-According to the IBC, which of the following use Groups require visual

notification?


Every 4 hours - Answer✔✔-Digital Alarm communicator transmitters (DACT) which use call forwarding to

the DACR shall be tested with what frequency?


True - Answer✔✔-When connecting 4 wires smoke detectors to a fire alarm system, the power

conductors shall be monitored for integrity.




Page 2/9
$9.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EmillyCharlotte Howard Community College
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
94
Miembro desde
1 año
Número de seguidores
4
Documentos
11951
Última venta
2 días hace
ALL-MAJOR.

On this page, you find all documents, package deals, and flashcards offered by seller Emilly Charlotte.

3.6

20 reseñas

5
7
4
6
3
2
2
2
1
3

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes