Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 1 fuera de 3 páginas
Examen

Test Bank Solution Manual for Auto Fire Sprinkler Systems Graded A+

Document preview thumbnail
Vista previa 1 fuera de 3 páginas

Test Bank Solution Manual for Auto Fire Sprinkler Systems Graded A+ Design density - Answers Minimum all sprinkler heads in a remote area must be up to deliver the stated minimum amount of water for required amount time Nfpa 11 - Answers Low,medium, high expansion foam design, installation, testing,maintenance Nfpa14 - Answers Standard for installation of standpipe and hoes systems Nfpa 30 - Answers Flammable combustible liquids code Nfpa15 - Answers Water spray fixed systems for fire protection NFPA 16 - Answers Standard for installation of foam water sprinkler in foam water spray systems NFPA 750 - Answers Standard on Watermist protection systems NFPA 409 - Answers Aircraft hangers Types of specialized water-based fire protection systems - Answers Fixedfoam, Waterspray fixed, Watermist foam, water sprinkler and foam water spray systems, ultra high-speed water spray systems Ultra high-speed water spray system - Answers Specialize fire protection system that requires water and piping all the time designed to protect explosive hazards within 100 millisec of detection Foam systems - Answers Fixed, semi fixed, portable, mobile Low expansion foam - Answers Ratio 2 to 1 220 to 1 meaning volume of foam increase is up to 20 times from the original volume of foam concentrate Medium expansion foam - Answers Ratio 20 to 1 to 200 to 1 Hi expansion foam - Answers Ratio 200 to 1 to 1000 to 1 Fixed foam system components - Answers Proportioner,foam concentrate tank,generating distributing equipment, pumps Foam proportions methods - Answers Venturi, pressure , balance pressure proportionate Balanced pressure proportioner - Answers Uses atmospheric tank and pump: direct injection variable output, coupled water motor pumps,balance pressure pump proportioner's Foam concentrate tanks - Answers Usually made of fiberglass so phone will not react. Tanks made of steel will have a bladder Type of Pump used for fix foam system - Answers Positive displacement because centrifugal pumps made out were with foam concentrates viscosities hi Minimum nozzle pressure defined by NFPA 15 - Answers 20 psi Deflagration - Answers Ignition of flammable gas mixture that proceeds at less than the speed of sound Detonation - Answers Ignition a flammable gas mixture that proceeds at greater than the speed of sound Foam water sprinkler system - Answers Use a standard sprinkler heads to apply phone agent over hazard area once foam is applied water than clothes clothes I said flows Phone water spray system - Answers Fire protection system that uses special spray nozzles to apply a phone agent over a specific hazard and wants exhausting the phone agent close water Preprimed - Answers A wet phone water sprinkler system where the piping holds a foam solution in the piping instead of water Watermist systems - Answers Fire protection system that uses specialize spray nozzles to discharge a very fine Watermist Watermist systems - Answers Protect lamp for Sony's including labs data centers underground transit centers transformer areas aircraft hangers museums marine in offshore facilities such as yachts cargo naval ships turbine room Three types of Watermist systems - Answers Low pressure less than one 175 PSI, intermediate pressure system 175 to 500 psi, high-pressure systems I want to psi plus in addition In addition to Watermist systems - Answers Single or twin fluid systemsSingle fluid systems only have one pipe supply water to the nozzle. When fluid has two pipes one for gas and one for water. Twin fluid systems want to miss system - Answers The purpose of gas compressed air or nitrogen mixed with water at the nozzle make droplets smaller Watermist nozzles - Answers Can be automatic nonautomatic, or hybrid Automatic nozzles - Answers Have built in detection and activate devices that operate independently of other nozzles

Vista previa del contenido

Test Bank Solution Manual for Auto Fire Sprinkler Systems Graded A+

Design density - Answers Minimum all sprinkler heads in a remote area must be up to deliver the stated
minimum amount of water for required amount time

Nfpa 11 - Answers Low,medium, high expansion foam design, installation, testing,maintenance

Nfpa14 - Answers Standard for installation of standpipe and hoes systems

Nfpa 30 - Answers Flammable combustible liquids code

Nfpa15 - Answers Water spray fixed systems for fire protection

NFPA 16 - Answers Standard for installation of foam water sprinkler in foam water spray systems

NFPA 750 - Answers Standard on Watermist protection systems

NFPA 409 - Answers Aircraft hangers

Types of specialized water-based fire protection systems - Answers Fixedfoam, Waterspray fixed,
Watermist foam, water sprinkler and foam water spray systems, ultra high-speed water spray systems

Ultra high-speed water spray system - Answers Specialize fire protection system that requires water and
piping all the time designed to protect explosive hazards within 100 millisec of detection

Foam systems - Answers Fixed, semi fixed, portable, mobile

Low expansion foam - Answers Ratio 2 to 1 220 to 1 meaning volume of foam increase is up to 20 times
from the original volume of foam concentrate

Medium expansion foam - Answers Ratio 20 to 1 to 200 to 1

Hi expansion foam - Answers Ratio 200 to 1 to 1000 to 1

Fixed foam system components - Answers Proportioner,foam concentrate tank,generating distributing
equipment, pumps

Foam proportions methods - Answers Venturi, pressure , balance pressure proportionate

Balanced pressure proportioner - Answers Uses atmospheric tank and pump: direct injection variable
output, coupled water motor pumps,balance pressure pump proportioner's

Foam concentrate tanks - Answers Usually made of fiberglass so phone will not react. Tanks made of
steel will have a bladder

Type of Pump used for fix foam system - Answers Positive displacement because centrifugal pumps
made out were with foam concentrates viscosities hi

Minimum nozzle pressure defined by NFPA 15 - Answers 20 psi

Información del documento

Subido en
5 de octubre de 2024
Número de páginas
3
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$8.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TutorJosh
3.4
(74)
Vendido
470
Seguidores
16
Artículos
32483
Última venta
23 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes