Exam Study Guide for Sprinkler Systems Rated A+ When will the red vial break in a sprinkler system - Answers Depending on the heat that is admitted What is the main defense against fires in a building - Answers Sprinkler system Who should be formed the maintenance an inspection of a sprinkler system - Answers Must be done by a third party What temperature will the vial break at - Answers 182 degrees Celsius What two types of sprinkler systems do you get - Answers A wet sprinkler system and a dry sprinkler system Definition of wet sprinkler system - Answers There's water in the line at all times it is fitted on the inside of the building and as a standpipe connection Definition of a dry sprinkler system - Answers It is filled with a or nitrogen and used on the outside of the building like a Parkade there is a time limit to when water comes out of the sprinkler pre-action valve opens up and water pushes out the air or nitrogen extinguishing the fire What is a fire pump - Answers A fire pump is used in the case where the city water pressure is not enough to raise the water to the top floor in the sprinkler system of a building When should a fire pump be inspected - Answers A fire pump should be inspected monthly What test must be done annually on a fire pump - Answers A float this must be done

Vista previa del contenido

Exam Study Guide for Sprinkler Systems Rated A+

When will the red vial break in a sprinkler system - Answers Depending on the heat that is admitted

What is the main defense against fires in a building - Answers Sprinkler system

Who should be formed the maintenance an inspection of a sprinkler system - Answers Must be done by
a third party

What temperature will the vial break at - Answers 182 degrees Celsius

What two types of sprinkler systems do you get - Answers A wet sprinkler system and a dry sprinkler
system

Definition of wet sprinkler system - Answers There's water in the line at all times it is fitted on the inside
of the building and as a standpipe connection

Definition of a dry sprinkler system - Answers It is filled with a or nitrogen and used on the outside of the
building like a Parkade there is a time limit to when water comes out of the sprinkler pre-action valve
opens up and water pushes out the air or nitrogen extinguishing the fire

What is a fire pump - Answers A fire pump is used in the case where the city water pressure is not
enough to raise the water to the top floor in the sprinkler system of a building

When should a fire pump be inspected - Answers A fire pump should be inspected monthly

What test must be done annually on a fire pump - Answers A float this must be done

Deluge fire system - Answers In this system there is a water tank placed on the roof which is connected
to the sprinkler system and is gravity feeding it water into system

How many sprinklers will be set off in case of a fire - Answers I need the sprinkler affected by the fire
directly one at a time

Where is the pre-action valve located - Answers In water entry rooms

Where do you find wet pipe systems - Answers Office Buildings schools manufacturing facilities hotels
Healthcare facilities

Where do you find dry pipe systems - Answers Outside canopies instructions and Cold Storage
warehouses

Maximum pressure allowed in a dry pipe system - Answers 275 KVA

The process which causes fires to endure and renew themselves - Answers Molecular activity due to
high temperature spontaneous combustion

Información del documento

Subido en
5 de octubre de 2024
Número de páginas
1
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$8.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TutorJosh
3.4
(74)
Vendido
470
Seguidores
16
Artículos
32483
Última venta
23 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes