Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 4 fuera de 87 páginas
Examen

BREAST ARDMS EXAM WITH COMPLETE QUESTIONS AND CORRECT ANSWERS RATED A+

Document preview thumbnail
Vista previa 4 fuera de 87 páginas

BREAST ARDMS EXAM WITH COMPLETE QUESTIONS AND CORRECT ANSWERS RATED A+

Vista previa del contenido

BREAST ARDMS EXAM WITH COMPLETE
QUESTIONS AND CORRECT ANSWERS
RATED A+

Which method of patient positioning is the best for evaluation the
medial aspect of the breast ? Correct Answer Supine

The two-handed technique is used to image : Correct Answer
The main breast duct and nipple

Which of the following transducers would be the best choice for
breast imaging ? Correct Answer 10 MHz linear array

Selecting multiple focal zones will : Correct Answer Decrease
frame rate

When viewing a mammogram, one always sees the marker in the
region toward : Correct Answer Axilla

If a breast sonographic image is labeled "Rt. AR 2:00 1A", the
area described is : Correct Answer Antiradial scan of the right
breast, upper inner quadrant near the nipple, under the skin

When viewing a mammogram, a mass is marked near the CC
marker in the right breast. This will indicate to the sonographer
that the mass is located : Correct Answer In the lateral breast

A transducer that can operate at multiple frequencies is said to
have : Correct Answer Broad bandwidth

All of the following statements about high-frequency transducers
are true : Correct Answer - Axial resolution is increased
- Lateral resolution is increased

,- Sound penetration is decreased
- Best for breast imaging

The following statement about high-frequency transducers is false
: Correct Answer Sound travels faster

Decreasing depth will : Correct Answer Increase the frame rate

Increasing the overall gain control will : Correct Answer Cause
artifactual echoes

What allows for better demonstration of small, tortuous vessels ?
Correct Answer Power doppler

What affects the frame rate ? Correct Answer Number of focal
zones and size of image

Ideally, the elevational focus for breast imaging should be fixed at
: Correct Answer 1.5 cm

An increase in the intensity of echoes beneath a structure is
called : Correct Answer Enhancement

What is not a good indication for performing a breast sonogram?
Correct Answer Evaluate a mass for microcalcifications

When setting the TGC control for breast imaging, the following
tissue should demonstrate a medium level of gray. Correct
Answer Fat

The lactiferous ducts are best seen when scanning : Correct
Answer Radial

The orthogonal (defined as perpendicular) view from the
longitudinal scan is : Correct Answer Transverse

,Adequate penetration of the breast is determined by imaging the :
Correct Answer Pectoral muscles

If a mass is isoechoic with surrounding tissues, what maneuver
would accentuate the mass to make it show up better ? Correct
Answer Apply harmonics

What transducer feature would not be good for breast imaging ?
Correct Answer Curved linear array format

Lateral resolution is best at the : Correct Answer Focal zone

Which technique would eliminate useful artifacts such as posterior
enhancement and shadowing? Correct Answer Spatial
compound imaging

According to AIUM standards, all of the following information
should be indicated on sonographic images : Correct Answer -
Patient's name / ID #
- Patient's age
- Facility name
- Date

What information should not be indicated of sonographic images
? Correct Answer Patient's social security number

What is considered an appropriate annotation method for breast
imaging ? Correct Answer - Side / Quadrant
- Clock face
- 123-ABC

What statement would be false when considering doppler artifacts
? Correct Answer If the gain and filter settings are too low, it can
cause noise

, What statements are true when considering doppler artifacts ?
Correct Answer - If the filter setting is too high, it will inhibit the
ability to detect low-velocity blood flow.
- A PRF / velocity scale that is too low will cause aliasing.
- If the doppler angle is perpendicular to flow, no flow will be
detected.
- Spectral mirroring causes a duplication of the waveform on the
opposite side of the baseline

What is true about propagation speed error ? Correct Answer - If
the propagation speed is slower than 1540 m/sec, posterior
echoes will be displayed on he sonogram deeper than they
actually are.

- If the propagation speed is faster than 1540 m/sec, reflectors will
appear closer to the transducer than they actually are.

The brightness of echoes on an ultrasound image is affected by :
Correct Answer - Overall gain
- Power output
- Dynamic range
- TGC

The brightness of echoes on an ultrasound image is not affected
by : Correct Answer Transducer frequency

What would not be part of the examination preparation? Correct
Answer Present the informed consent to the patient for signature

What would be part of the examination preparation? Correct
Answer - Obtain pertinent clinical information from the patient.
- Explain the examination to the patient.
- Review the pertinent correlative imaging tests.
- Know the indication for the exam.

Información del documento

Subido en
30 de septiembre de 2024
Número de páginas
87
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$26.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Topbrainers
3.0
(2)
Vendido
9
Seguidores
0
Artículos
352
Última venta
5 meses hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes