NERC EXAM, TEST, PRACTICE EXAM AND STUDY GUIDE
LATEST ACTUAL EXAM
What is ACE? - ANSWER: (NIa - NIs) - 10β(fa - fs) - Ime
Calculated every 6 seconds
Uses Tie line Frequency Bias

What is Tie line deviation? - ANSWER: Largest offset to ACE

What is NIA? - ANSWER: Net Interchange Actual (sum of all tie-line values)

What is NIS? - ANSWER: Net Interchange Scheduled (sum of all interchange
schedules)

What is the multiplier for frequency bias? - ANSWER: 10

What is β? - ANSWER: Frequency bias - represented as negative number in ACE
calculation - reflects area natural response to frequency changes (Inertia, Governor,
Load) - atleast 1% of annual peak load for areas with native load - 1% of peak
generation output for area with no load

What is FA? - ANSWER: Frequency Actual

What is FS? - ANSWER: Frequency Schedule - normally 60.00 HZ except for time
corrections - +/- .02 Hz

What is IME? - ANSWER: Meter error
fudge factor
used for inadvertent bilateral payback
Negligible

What should be done if unable to calculate ACE for 30 minutes? - ANSWER: Contact
RC

How often should time error and frequency devices be checked/calibrated? -
ANSWER: Annually

Negative Ace - ANSWER: The BA is Undergenerating

Positve ACE - ANSWER: The BA is Overgenerating

What happens during Internal Loss of Load? - ANSWER: Frequency and ACE increase.

What happens during External Loss of Load? - ANSWER: Frequency increases, no
change in ACE.

, What is the Frequency Bias Setting? - ANSWER: Monthly average >= 1% of estimated
yearly peak demand per 0.1 Hz

When should the Balancing Authority recalculate its Frequency Bias Setting? -
ANSWER: By January 1 of each year

What happens when there is internal generation loss? - ANSWER: Frequency and
ACE drop, tie-line flows increase into the system

What happens when there is external generation loss? - ANSWER: Frequency drops,
no change in ACE, net tie-line flows increase out of the system

What happens when Frequency bias setting is lower than frequency response? -
ANSWER: ACE will be positive causing the AGC to lower generation

What is the percentage change in load required for a 1% change in frequency? -
ANSWER: 1% - 2% change in load

What is the load reduction when Transmission Customer Voltage is reduced by 5%? -
ANSWER: Load will reduce by 3%

What happens to ACE and AGC when the frequency bias setting is set to a less
negative value than the frequency response of a Balancing Authority and a frequency
increase is caused by a sudden loss of load in an external balancing area? - ANSWER:
ACE will be a negative value and AGC will increase generation

What happens to ACE and AGC when the frequency bias setting is less negative than
the frequency response of a Balancing Authority and a frequency decline is caused
by a sudden loss of generation in an external balancing area? - ANSWER: ACE will be
a positive value and AGC will lower generation

What is the normal schedule frequency? - ANSWER: 60.00 Hz

What is the frequency correction for fast clock schedule? - ANSWER: 59.98 Hz

What is the frequency corrections for a slow clock schedule? - ANSWER: 60.02 Hz

When does frequency increase? - ANSWER: Generation increases or load decreases

When does frequency decrease? - ANSWER: Generation decreases or load increases

Who is the Time Monitor? - ANSWER: Can only be RC
one per Interconnection

Who is designated as Interconnection Time Monitor? - ANSWER: Single RC
designated by NERC Operating Committee
$17.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
tutorsection1 Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
40
Miembro desde
1 año
Número de seguidores
8
Documentos
1080
Última venta
1 semana hace

4.9

439 reseñas

5
400
4
30
3
7
2
1
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes