Redo Multimeter Test UPDATED Actual Exam Questions and CORRECT Answers After testing the fuses it was determined that the 0.5 amp fuse was bad. Student A indicates they do NOT have an exact replacement fuse, but a cheaper replacement fuse of similar size is acceptable to use. Student B states the correct replacement fuse is specially designed to protect the user in case of an unexpected high amperage draw. Who is correct? - CORRECT ANSWER- Student B

Vista previa del contenido

Redo Multimeter Test UPDATED Actual
Exam Questions and CORRECT Answers
After testing the fuses it was determined that the 0.5 amp fuse was bad. Student A indicates
they do NOT have an exact replacement fuse, but a cheaper replacement fuse of similar size
is acceptable to use. Student B states the correct replacement fuse is specially designed to
protect the user in case of an unexpected high amperage draw. Who is correct? - CORRECT
ANSWER✔✔✔- Student B


A student uses a multimeter to measure a resistance of a wire and gets a reading of 7.4 k?
What would this value be in ohms ? - CORRECT ANSWER✔✔✔- 7400 ohms



The function buttons on the meter may be used to ______ - CORRECT ANSWER✔✔✔-
Both A and B


Using the illustration, with the rotary dial set to test micro-amps which two test lead terminal
locations should be used? - CORRECT ANSWER✔✔✔- Terminals 2 and 3


A student can compare known values to measured values when using the REL function of the
multimeter - CORRECT ANSWER✔✔✔- True


Of the following four diagnostic products which is the best suited for making exact voltage
measurements when pinpoint testing an electronic circuit. - CORRECT ANSWER✔✔✔-
High impedance digital multi-meter


Safety is a concern when using the test instruments. Protect yourself by testing the meters for
one of the following before conducting any tests. - CORRECT ANSWER✔✔✔- Test leads
for breaks for damage.


Safety is a concern when using the test instruments. You can protect yourself by testing the
meters for one of the following before conducting any tests. - CORRECT ANSWER✔✔✔-
Test for good meter fuses

, Student A states using the Amperage setting on the multi meter you can measure the current
flow in a circuit. Student B states that the Frequency setting is used to test for Ohms. Who is
correct? - CORRECT ANSWER✔✔✔- Student A


The bar graph on the display enables the user to see __________ more easily. - CORRECT
ANSWER✔✔✔- rapidly changing signals


To capture a maximum value automatically during testing, which function button would you
press? - CORRECT ANSWER✔✔✔- REC


Using the illustration, with the rotary dial set to measure capacitance which two test leads
terminal location should be used? - CORRECT ANSWER✔✔✔- Terminals 3 and 4


When using the meter in the Frequency setting you are measuring what? - CORRECT
ANSWER✔✔✔- The number of times per second a signal happens


Which of the following rotary dial setting would be best for measuring the number of cycles
per second. - CORRECT ANSWER✔✔✔- Hz


The meter is set-up and testing mV but an OL reading is displayed to correct this situation.
Student A state the REL button should be pressed. Student B state the RANGE button should
be pressed. Who is correct? - CORRECT ANSWER✔✔✔- Student B


Which function button sets the display to zero and factors out undesired reading? -
CORRECT ANSWER✔✔✔- REL


Two Students are discussing the HOLD function button. Student A states the HOLD button
will pause or freeze the screen to capture a reading. Student B states the pressing the HOLD
button again will return to the live electrical reading. Who is correct? - CORRECT
ANSWER✔✔✔- Both Student A and Student B



What does it mean when a meter has "high-impedance" - CORRECT ANSWER✔✔✔- Can
measure a high voltage

Información del documento

Subido en
14 de septiembre de 2024
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$8.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MGRADES
3.8
(246)
Vendido
1487
Seguidores
106
Artículos
102621
Última venta
8 horas hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes