Audiology Praxis Study Questions with Correct Answers What features of an assessment will affect reliability - Answer-test-retest, inter-tester and inter-rater reliability. Classroom noise acceptable noise level - Answer-35dBA and less or equal to .6 seconds reverberation time OSHA how much sound for 8 hours - Answer-85dB: then it goes down by half time for every 5 dB increase NIOSH is ____ stringent than OSHA - Answer-more Workplace portable eqiupment - Answer-portable audiometer, tymps and OAES, Sound level meter Screening levels for kids vs adults - Answer-20dB for kids vs 30dB for adults standard threshold shift - Answer-10dB down from baseline in either ear from the puretone average of 2k, 3k and 4k. Time weighted average - Answer-time you're able to be exposed to a certain amount of noise Person failed a screening, then what - Answer-screen again, make sure they are noise free for 14 hours, see if an age directive needs to be applied in case it's presbycusis. JIH screening guidelines - Answer-1, 3, 6 : screen, diagnose, treat Headphone options - Answer-TDH headphones (on the ear): some high frequencies might slip out, good for people with medical stuff (40dB IAA) Over the ear headphones: high frequency audiometry inserts: better for high frequencies but easier to collapse ear canals, also you don't have mask as much (60dB) Why is the warble tone used in the sound field - Answer-so standing waves aren't created

Mostrar más Leer menos
Institución
Audiology Praxis
Grado
Audiology Praxis









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Audiology Praxis
Grado
Audiology Praxis

Información del documento

Subido en
13 de septiembre de 2024
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Audiology Praxis Study Questions
with Correct Answers

What features of an assessment will affect reliability - Answer-test-retest, inter-tester
and inter-rater reliability.

Classroom noise acceptable noise level - Answer-35dBA and less or equal to .6
seconds reverberation time

OSHA how much sound for 8 hours - Answer-85dB: then it goes down by half time for
every 5 dB increase

NIOSH is ____ stringent than OSHA - Answer-more

Workplace portable eqiupment - Answer-portable audiometer, tymps and OAES, Sound
level meter

Screening levels for kids vs adults - Answer-20dB for kids vs 30dB for adults

standard threshold shift - Answer-10dB down from baseline in either ear from the
puretone average of 2k, 3k and 4k.

Time weighted average - Answer-time you're able to be exposed to a certain amount of
noise

Person failed a screening, then what - Answer-screen again, make sure they are noise
free for 14 hours, see if an age directive needs to be applied in case it's presbycusis.

JIH screening guidelines - Answer-1, 3, 6 : screen, diagnose, treat

Headphone options - Answer-TDH headphones (on the ear): some high frequencies
might slip out, good for people with medical stuff (40dB IAA)
Over the ear headphones: high frequency audiometry
inserts: better for high frequencies but easier to collapse ear canals, also you don't have
mask as much (60dB)

Why is the warble tone used in the sound field - Answer-so standing waves aren't
created

WRS presented at - Answer-30 above SRT or 5 below LDL/UCL

jerger type A - Answer-normal

, jerger type B - Answer-flat

jerger type C - Answer-negative

jerger type D - Answer-high admittance

reflex decay indications? - Answer-neuroma, schwannoma

Subjective questionnaires - Answer-APHAB, COSI, HHIE, COAT

Rotational testing - Answer-no ear specific information, looks at the whole body.
Indicated when you have an inconclusive VNG.

Cold water is used in VNG/ENG to - Answer-inhibit the auditory system. Shocks the
system if you can't get a response with cool or warm

Gaze - Answer-look different directions

saccade parameters - Answer-accuracy, latency, peak velocity [random dots and
movements]

Acoustic parameters - Answer-amplitude, frequency, phase, wavelength

frequency is the inverse of - Answer-period

period = - Answer-1/f

libbyhorn - Answer-used to increase high frequency response

longer the libbyhorn - Answer-the more high frequency boost

precedence effect - Answer-if a sound is coming from two directions and arrives at the
same time, you will localize whichever sound is louder

ILD - Answer-interaural level difference

vowels carry ____ energy than consonants - Answer-more

At what frequencies and intensities are most speech sounds produced? - Answer-
Around 40-50dB and between 250 and 500.

What is the relationship between SPL and HL? - Answer-The difference is biggest in the
low and high frequencies, and smallest in the mid frequencies. HL has been normed on
lots of normal hearing people to create a more visually appealing scale.
$11.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Scholarsstudyguide nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
782
Miembro desde
3 año
Número de seguidores
475
Documentos
15281
Última venta
12 horas hace
NURSING

Here you will find everything you need in nursing Assignments, EXAMS AND TESTBANKS. For students who want to see results twice as fast. I strive for my content to be of the highest quality. Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied.

3.9

164 reseñas

5
87
4
21
3
26
2
6
1
24

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes