Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 1 fuera de 3 páginas
Examen

Compression - Refrigeration System Operations Exam Questions and Answers

Document preview thumbnail
Vista previa 1 fuera de 3 páginas

Why must you avoid running a refrigeration system below 14 kPa when pumping down - Answer-A slightly positive system pressure is required to prevent air infiltration This safety control device used on a centrifugal compressors allows the motor to be started unloading - Answer-Vane closed switch What is the purpose of the chilled water flow switch - Answer-Protects the chiller from freezing due to lack of waterflow Where can refrigeration system log sheets be obtained from - Answer-1. Refrigeration system manufacturers. 2. Inspection and insurance companies. 3. Developed by the refrigeration system operator. Which of the following is not a benefit of a preventative maintenance program - Answer-Allows for the accumulation of all spare parts for each piece of equipment in case of a major breakdown What is the symptom of a refrigeration system that has high suction pressure due to an oversized expansion valve - Answer-An abnormally cold suction line If the compressor fails to start but the motor is running, which of the following could be a cause - Answer-The coupling is sheared or broken Why is it recommended that a refrigeration log sheet be used - Answer-It can indicate changes in the system operation The safety control in a centrifugal compressor, which ensures the compressor will only be started under a no-load condition, it's called - Answer-Vane closed switch Which of the following steps is not a step in the start of a reciprocating or Rotary compressor refrigerating system - Answer-Valves in lines connecting suction gauges should be closed If the temperature drops 2.5 - 3°C, below the set point, this Safety control device used on a centrifugal compressor will shut down the compressor. - Answer-Chilled water low-temperature cut out Vane closed switch - Answer-Allows the motor to be started under no load

Vista previa del contenido

Compression - Refrigeration System
Operations Exam Questions and
Answers
Why must you avoid running a refrigeration system below 14 kPa when pumping down -
Answer-A slightly positive system pressure is required to prevent air infiltration

This safety control device used on a centrifugal compressors allows the motor to be
started unloading - Answer-Vane closed switch

What is the purpose of the chilled water flow switch - Answer-Protects the chiller from
freezing due to lack of waterflow

Where can refrigeration system log sheets be obtained from - Answer-1. Refrigeration
system manufacturers.
2. Inspection and insurance companies.
3. Developed by the refrigeration system operator.

Which of the following is not a benefit of a preventative maintenance program - Answer-
Allows for the accumulation of all spare parts for each piece of equipment in case of a
major breakdown

What is the symptom of a refrigeration system that has high suction pressure due to an
oversized expansion valve - Answer-An abnormally cold suction line

If the compressor fails to start but the motor is running, which of the following could be a
cause - Answer-The coupling is sheared or broken

Why is it recommended that a refrigeration log sheet be used - Answer-It can indicate
changes in the system operation

The safety control in a centrifugal compressor, which ensures the compressor will only
be started under a no-load condition, it's called - Answer-Vane closed switch

Which of the following steps is not a step in the start of a reciprocating or Rotary
compressor refrigerating system - Answer-Valves in lines connecting suction gauges
should be closed

If the temperature drops 2.5 - 3°C, below the set point, this Safety control device used
on a centrifugal compressor will shut down the compressor. - Answer-Chilled water low-
temperature cut out

Vane closed switch - Answer-Allows the motor to be started under no load

Información del documento

Subido en
9 de septiembre de 2024
Número de páginas
3
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$10.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
lectknancy
3.8
(80)
Vendido
328
Seguidores
27
Artículos
26139
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes