100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

MDCB Practice Questions With 100% Verified Correct Answers

Puntuación
-
Vendido
-
Páginas
15
Grado
A+
Subido en
07-09-2024
Escrito en
2024/2025

MDCB Practice Questions With 100% Verified Correct Answers A patient is to receive 55 Gy to a tumor in the mediastinum. In order to meet the acceptable dose limits for the spinal cord, you could: a. use high energy photon beams to decrease the entrance dose. b. block the spinal cord out of all treatment fields after 40 Gy is delivered. c. use a BID treatment technique to achieve greater repair time for the normal tissue cells. d. utilize a 3DCRT beam arrangement including oblique beam angles. - Correct Answer d. utilize a 3DCRT beam arrangement including oblique beam angles. Which of the following statements are true for Iodine-125? a. half-life 86.4 days. b. has life-long radiation protection issues. c. energy of 0.412 MeV. d. decays exclusively by electron capture. - Correct Answer d. decays exclusively by electron capture. The most significant effect(s) of an air cavity in a megavoltage beam treatment is: a. a change in the spectral energy distribution within the cavity. b. an increased primary photon transmission through the cavity. c. an enhanced absorption of dose in and beyond the cavity. d. a partial gain of electronic equilibrium at the cavity interface. - Correct Answer b. an increased primary photon transmission through the cavity. For patients with limited life expectancy the common dose fractionation for cord compression is: a. 800cGy in 1 fraction. b. 2000cGy in 5 fractions. c. 3000cGy in 10 fractions. d. 3750cGy in 15 fractions. - Correct Answer a. 800cGy in 1 fraction. Mayneord F factor corrects PDD for: a. heterogeneity. b. scatter. c. Inverse square. d. exponential attenuation. - Correct Answer b. Inverse square- does not correct for scatter For quality assurance of brachytherapy treatment planning computers, the dose rates should agree with published data tables to which of the following degrees? a. +- 1% b. +- 2% c. +- 3% d. +- 5% - C

Mostrar más Leer menos
Institución
MDCB
Grado
MDCB









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
MDCB
Grado
MDCB

Información del documento

Subido en
7 de septiembre de 2024
Número de páginas
15
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

MDCB Practice Questions With 100% Verified
Correct Answers
A patient is to receive 55 Gy to a tumor in the mediastinum. In order to meet the acceptable dose
limits for the spinal cord, you could:

a. use high energy photon beams to decrease the entrance dose.

b. block the spinal cord out of all treatment fields after 40 Gy is delivered.

c. use a BID treatment technique to achieve greater repair time for the normal tissue cells.

d. utilize a 3DCRT beam arrangement including oblique beam angles. - Correct Answer d. utilize a
3DCRT beam arrangement including oblique beam angles.



Which of the following statements are true for Iodine-125?

a. half-life 86.4 days.

b. has life-long radiation protection issues.

c. energy of 0.412 MeV.

d. decays exclusively by electron capture. - Correct Answer d. decays exclusively by electron capture.



The most significant effect(s) of an air cavity in a megavoltage beam treatment is:

a. a change in the spectral energy distribution within the cavity.

b. an increased primary photon transmission through the cavity.

c. an enhanced absorption of dose in and beyond the cavity.

d. a partial gain of electronic equilibrium at the cavity interface. - Correct Answer b. an increased
primary photon transmission through the cavity.



For patients with limited life expectancy the common dose fractionation for cord compression is:

a. 800cGy in 1 fraction.

b. 2000cGy in 5 fractions.

c. 3000cGy in 10 fractions.

d. 3750cGy in 15 fractions. - Correct Answer a. 800cGy in 1 fraction.



Mayneord F factor corrects PDD for:

a. heterogeneity.

b. scatter.

, c. Inverse square.

d. exponential attenuation. - Correct Answer b. Inverse square- does not correct for scatter



For quality assurance of brachytherapy treatment planning computers, the dose rates should agree
with published data tables to which of the following degrees?

a. +- 1%

b. +- 2%

c. +- 3%

d. +- 5% - Correct Answer b. +- 2%



The expected accuracy of treatment planning systems that perform brachytherapy dose calculations
should be within: a. +/- 3%

b. +/- 5%

c. +/- 7%

d. +/- 10% - Correct Answer b. +/- 5%



With LINAC based SBRT/SABR and a plan that has a 100% maximum IDL, what is the typical range of
prescription isodose line covering the PTV?

a. 40 - 60 %

b. 60 - 90 %

c. 90 - 100 %

d. > 100 % - Correct Answer c. 90 - 100 %



The ratio of the dose rate of a given field size to the dose rate of the reference field size is:

a. Relative output factor

b. Back scatter factor

c. Percent depth dose

d. Tissue maximum ratio - Correct Answer A. Relative output factor



During which stage of mitosis do the chromosomes align across the equator of the spindle fibers?

a. prophase

b. metaphase
$10.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Winfred West Virgina University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
756
Miembro desde
3 año
Número de seguidores
473
Documentos
7353
Última venta
1 día hace
StudySmart

Revising without a good structure can be so frustrating but with StudySmart you are able to get revision questions, summary notes and exams to help you pass with flying colors

3.9

157 reseñas

5
78
4
28
3
26
2
8
1
17

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes