Air Conditioning and Refrigeration Air Conditioning and Refrigeration Air Conditioning and Refrigeration Air Conditioning and Refrigeration Air Conditioning and Refrigeration Air Conditioning and Refrigeration Air Conditioning and Refrigeration Air Conditioning and Refrigeration Air Conditioning and Refrigeration Air Conditioning and Refrigeration

Vista previa del contenido

Air Conditioning and Refrigeration
After disconnecting the refrigerant cylinder during leak troubleshooting it is replaced with a cylinder
of what type of inert gas? - ANSWER-Nitrogen

After how many hours of initial use it is recommended to renew the dehydrator charge in a new or
newly charged refrigeration system? - ANSWER-12-15

Air conditioning hydraulic hoses are hydrostatically tested at how many month intervals? - ANSWER-
60

Can refrigerant gases ever be mixed? - ANSWER-No

Compressor suction valves are working satisfactorily when checking them for proper operation if the
compressor can hold a minimum of how many inches of vacuum with the line stop valve shut? -
ANSWER-20" Hg

Cooling coils must be deefrosted when the average frost thickness reaches how many inches? -
ANSWER-3/16"

How are refrigerant leaks detected? - ANSWER-Electronic tester or soapsuds

How is chill water piping color coded? - ANSWER-Striped light blue and dark green

How many hours at a minimum must the system hold system pressure for with no pressure loss after
all refrigerant leaks have been found and corrected? - ANSWER-6

How many personnel must be present when charging a refrigeration system? - ANSWER-2

How often are air conditioning lube oil samples submitted to NOAP? - ANSWER-Quarterly

How often are machinery resilient mounts inspected? - ANSWER-Annually

How often at a minimum are operating refrigeration plant moisture indicators inspected? - ANSWER-
Weekly

How often at a minimum is it recommended to test the air conditioning control system for proper
operation? - ANSWER-Quarterly

How often at a minimum is the lube oil checked via the crackcase sight glass during operation? -
ANSWER-Daily

How often at a minimum must refrigerant usage logs be reviewed? - ANSWER-Monthly

How often is testing of refrigerant systems for leaks accomplished IAW PMS? - ANSWER-Semi
annually

If vapor bubbles can be noticed when viewing the flow of refrigerant through a sight flow indicator it
could indicate an inadequate supply of what? - ANSWER-Refrigerant

Inspecting solenoid coils, cleaning valves, or which other action must be taken if you suspect the
thermostatic cooling-coil magnetic valve is not operating? - ANSWER-Adjust pilots

Lithium bromide absorption along with which other type of chilled-water air conditioning system are
used aboard ships? - ANSWER-Vapor compression

Refrigerant usage logs must be kept when the refrigeration plant holds how many or more pounds of
refrigerant? - ANSWER-50

, Air Conditioning and Refrigeration
Taking care of thermal expansion of the water, making up for small losses and ensuring that a
positive water pressure exists at the highest water coil are the two functions of what component? -
ANSWER-Expansion tank

The condenser must be immediately cleaned IAW which NSTM if it is discovered that the condenser
has greater than 10% of its tubes blocked in one pass? - ANSWER-254

The refrigerant liquid strainer is designed to protect what? - ANSWER-Solenoid valves and TXV

TXV valves are set to maintain a superheat range of how many degrees at the cooling coil outlet? -
ANSWER-4 - 12 F

Under normal conditions, what percentage of the full refrigerant load should the refrigerant charge
be with the compressor stopped under normal conditions? - ANSWER-85%

What actuates the compressor capacity control valve? - ANSWER-Oil pressure

What can be used to determine leak locations in a leaking air conditioning plant refrigerant system in
which the location of the leaks cannot be determined? - ANSWER-Fluorescent dye

What controls the capacity of a refrigerant compressor? - ANSWER-Cylinder loading and unloading

What is installed in condenser heads to protect the condenser from corrosion? - ANSWER-Zinc

What is not permitted in the vicinity of performing recovery of refrigerant? - ANSWER-Hot work

What is the allowable monthly leakage rate of the total air conditioning charge minus reported
accidental or unintentional releases? - ANSWER-15%

What is the allowable monthly leakage rate of the total refrigerant charge minus the reported
accidental or unintentional releases? - ANSWER-35%

What is the first indication of a refrigerant shaft seal failure? - ANSWER-Oil leakage

What is the max moisture content of an oil sample drawn from a centrifugal compressor? - ANSWER-
100 PPM

What is the maximum allowable crankshaft oil seal leakage criteria on a reciprocating compressor? -
ANSWER-Less than 1 drop every 5 mins

What is the maximum percentage of condenser tubes that can be plugged in a refrigerant system? -
ANSWER-10%

What is the maximum seawater temperature that all R-134a reciprocating air conditioning and
refrigeration plants are designed to operate with? - ANSWER-85 F

What is the maximum temperature that refrigerant bottles should be exposed to? - ANSWER-130 F

What is the problem if while conducting a compressor discharge valve test, the discharge pressure
drops at a rate in excess of 3 pounds a minute and the crackcase pressure rises? - ANSWER-
Compressor discharge valve leakage

What is the service life of air conditioning hoses? - ANSWER-Indefinite

What is the setting of the condenser water regulating valves on an R-134 system? - ANSWER-130 -
135 PSIG

Información del documento

Subido en
28 de agosto de 2024
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$23.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Creativepdf
3.8
(5)
Vendido
38
Seguidores
28
Artículos
2597
Última venta
5 meses hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes