Mass oil burner exam questions with correct answers 100% Already Graded A

Document preview thumbnail
Vista previa 2 fuera de 6 páginas

Mass oil burner exam questions with correct answers 100% Already Graded A What must be done before removing an oil tank and where is it obtained? - ANSWERpermit, from the fire department All oil tanks over ________________ must have an open air vent pipe. Minimum pipe size of ___________. The fill pipe cannot exceed the size of vent pipe. Both must terminate _______________? - ANSWER10 gallons, 1 1/4", outside of building No more than how many gallon oil tank (1) can be exposed in a building? - ANSWER660 gallons Exposed tanks ( more than 1) in a building cannot be more than how many gallons? - ANSWER1320 What must be done with any unused openings on an oil tank? - ANSWERMade vapor tight What cannot be used for fill and vent piping? - ANSWERSolder copper tubing and fittings, or plastic piping. All oil tanks with fill and vent pipes must have what type of gauging device? - ANSWERVisual or audible The maximum total capacity of all the tanks located above the lowest level of a building cannot exceed how many gallons? - ANSWER60 The maximum total capacity of all the tanks located above the lowest level of a building has an exception what is it? - ANSWERA tank on slab adjacent to first floor Vent pipe mjst terminate at least how many feet above grade? - ANSWER3 feet Vent pipe must terminate ____ feet vertically and _______ horizontally from any building opening. - ANSWERTwo, two What mjst vent pipe have on the terminate outside of building? - ANSWERwater tight cap Fill and vent pipes are slopped in which direction? - ANSWERtowards tank re fixed sash windows considered a building opening to apply to fill and vent piping? - ANSWERNo What is the definition of confined space? - ANSWERA space supplying air for combustion whose volume is less than 50 cubic feet per 1000 btu per hour input of all appliances in the space What is the maximum voltage used for oil burner circuits? - ANSWER150v

Vista previa del contenido

Mass oil burner exam questions with correct answers 100%
Already Graded A

What must be done before removing an oil tank and where is it obtained? -
ANSWER>>permit, from the fire department


All oil tanks over ________________ must have an open air vent pipe.
Minimum pipe size of ___________. The fill pipe cannot exceed the size of
vent pipe. Both must terminate _______________? - ANSWER>>10 gallons, 1
1/4", outside of building


No more than how many gallon oil tank (1) can be exposed in a building? -
ANSWER>>660 gallons


Exposed tanks ( more than 1) in a building cannot be more than how many
gallons? - ANSWER>>1320


What must be done with any unused openings on an oil tank? -
ANSWER>>Made vapor tight


What cannot be used for fill and vent piping? - ANSWER>>Solder copper
tubing and fittings, or plastic piping.


All oil tanks with fill and vent pipes must have what type of gauging
device? - ANSWER>>Visual or audible


The maximum total capacity of all the tanks located above the lowest level
of a building cannot exceed how many gallons? - ANSWER>>60

, The maximum total capacity of all the tanks located above the lowest level
of a building has an exception what is it? - ANSWER>>A tank on slab
adjacent to first floor


Vent pipe mjst terminate at least how many feet above grade? -
ANSWER>>3 feet


Vent pipe must terminate ____ feet vertically and _______ horizontally from
any building opening. - ANSWER>>Two, two


What mjst vent pipe have on the terminate outside of building? -
ANSWER>>water tight cap


Fill and vent pipes are slopped in which direction? - ANSWER>>towards
tank


re fixed sash windows considered a building opening to apply to fill and
vent piping? - ANSWER>>No


What is the definition of confined space? - ANSWER>>A space supplying
air for combustion whose volume is less than 50 cubic feet per 1000 btu
per hour input of all appliances in the space


What is the maximum voltage used for oil burner circuits? -
ANSWER>>150v

Información del documento

Subido en
27 de agosto de 2024
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$14.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
QueenElsa
4.9
(61)
Vendido
82
Seguidores
36
Artículos
1013
Última venta
4 meses hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes