100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

DOD MWS cdc exam with 100% correct answers 2024/2025

Puntuación
-
Vendido
-
Páginas
15
Grado
A+
Subido en
26-08-2024
Escrito en
2024/2025

1. an MWS apparatus equipped with fire pump must have a tank to pump line at least 2 in in diameter and capable of supplying the pump with 500 GPM unit at least 80% of water in the tank is emptied 2. NMWS apparatus must be equipped with at least one external fuel connection connected into the tank that allows the tank to be filled at a minimum rate of 1000 GPM 3. The external fuel connection should be equipped with a valve strainer and 30° elbow 4. valves that are 3 in or larger must be of the slow closing design 5. an MWS apparatus must have at least three large tank discharge capable of discharging 90% of the tank volume at an average rate of 1,000 GPM correct answersidentify five requirements for a MWS apparatus that can be found in NFPA 1901 saddle tanks correct answerswhen checking the left front or right front side of the apparatus, don't forget to inspect: an independent testing agency correct answerspre-service pump certification tests are conducted by: 10,4 correct answerswhen using a static body of water as your water source during fire apparatus service testing the water surface must not be more than_____feet above the center line of the pump intake and the water must be at least____feet deep stop the testing until the problem is corrected correct answersif the engine speed check provides the MWS apparatus is running at a different speed than that which it was originally rated, you need to: 30 correct answerswhen conducting a priming device test and using a pump of less than 1500 GPM, the priming device should be able to create the necessary vacuum_____seconds to lift water 10 ft through 20 ft of hard suction hose And no less than 3 seconds and no more than 10 seconds correct answersThe three parts of the pressure control test require you to close the flowing valves one at a time:

Mostrar más Leer menos
Institución
DOD MWS Cdc
Grado
DOD MWS cdc









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
DOD MWS cdc
Grado
DOD MWS cdc

Información del documento

Subido en
26 de agosto de 2024
Número de páginas
15
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

DOD MWS cdc

1. an MWS apparatus equipped with fire pump must have a tank to pump line at least 2 in in diameter
and capable of supplying the pump with 500 GPM unit at least 80% of water in the tank is emptied

2. NMWS apparatus must be equipped with at least one external fuel connection connected into the
tank that allows the tank to be filled at a minimum rate of 1000 GPM

3. The external fuel connection should be equipped with a valve strainer and 30° elbow

4. valves that are 3 in or larger must be of the slow closing design

5. an MWS apparatus must have at least three large tank discharge capable of discharging 90% of the
tank volume at an average rate of 1,000 GPM correct answersidentify five requirements for a MWS
apparatus that can be found in NFPA 1901



saddle tanks correct answerswhen checking the left front or right front side of the apparatus, don't
forget to inspect:



an independent testing agency correct answerspre-service pump certification tests are conducted by:



10,4 correct answerswhen using a static body of water as your water source during fire apparatus service
testing the water surface must not be more than_____feet above the center line of the pump intake and
the water must be at least____feet deep



stop the testing until the problem is corrected correct answersif the engine speed check provides the
MWS apparatus is running at a different speed than that which it was originally rated, you need to:



30 correct answerswhen conducting a priming device test and using a pump of less than 1500 GPM, the
priming device should be able to create the necessary vacuum_____seconds to lift water 10 ft through
20 ft of hard suction hose



And no less than 3 seconds and no more than 10 seconds correct answersThe three parts of the pressure
control test require you to close the flowing valves one at a time:

, 10% correct answersThe gauge and flow meter test compares flow meter readings with actual pilot tube
readings. The two readings should differ no more than:



NFPA 1901 correct answersThe tank to pump flow rate test measures whether the piping between an
apparatus water tank and fire pump meets the minimum flow standard of:



1. keeps everyone on the team informed about equipment conditions

2. helps determine whether equipment should be repaired / replaced. correct answersidentify two most
important reasons for maintaining good MWS apparatus records.



start the engine without a load. correct answersan MWS apparatus should be started with all electrical
switches and the OFF position in order to:



20 ft of hard suction hose correct answerswhen testing the priming device on an MWS apparatus with a
fire pump with the capacity less than 1500 GPM, the priming device should be able to create the
necessary vacuum in 30 seconds to lift water 10 ft through:



1. road test

2. independent pump certification test

3. hydrostatic test

4. purchase acceptance test correct answersidentify four pre-service tests for an MWS apparatus
equipped with a fire pump



1. priming device

2. hard suction hose

3. pump correct answersidentify three items that are checked for leaks during vacuum test.



10 in and 5 minutes correct answerswhen performing a vacuum service test, once the engine is turned
on, the column of mercury should fall no more than:



1. tachometer

2. smooth bore tip
$16.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
QUILLSKY Yale University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
513
Miembro desde
2 año
Número de seguidores
275
Documentos
13973
Última venta
1 mes hace
,STUDY GUIDES,TESTBANKS AND QUALITY EXAMS IS THE KEY TO STUDENTS CAREER EXCELLENCE!!!

On this page, you find all documents, package deals, and flashcards offered by seller MAXGRADES WELCOME TO MAXGRADES ALL THE BEST !!!!!!

3.6

129 reseñas

5
49
4
23
3
29
2
6
1
22

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes