Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 5 páginas
Examen

FEX Seattle Study guide Questions And Answers Rated A+ New Update Assured Satisfaction

Document preview thumbnail
Vista previa 2 fuera de 5 páginas

The four methods for filling liquid agent shall be determined using these to prevent overfilling - Exact measurement by weight or volume, anti-overfill tube, fill mark on side of extinguisher For low pressure cylinders, if pressure is not specified on nameplate, what shall they be test to, but to to exceed three time service pressure? - factory test pressure DOT 3A, 3AA, or 3AL cylinders used as carbon dioxide extinguishers, OR nitrogen cylinders, argon cylinders, or carbon dioxide cylinders used with wheeled extinguishers shall be tested to what fraction of the service pressure, when on the topic of high pressure cylinders? - 5/3 All cylinders and apparatuses, except water based, need to have what happen after testing? - Thoroughly dried At what temperature should extinguishers having aluminum cylinders or shells suspected of being exposed to this temperature be removed from service and hydrotested? - 350F Cartridge and cylinder operated dry chemical and dry powder types shall be hydro'd at what test pressure? - Original factory test pressure Class D hazard fire extinguisher travel distance? - 75 ft Class K hazard maximum travel distance? - 30 ft Cylinders (except those charged with carbon dioxide) complying with 49 CFR 180.2098(b) shall be permitted to be hydro tested how often? - Every 10 years Cylinders & cartridge bearing what two symbols are regulated to their own regulations - DOT and TCExtinguishers manufactured prior to what date are not required to have as strict of labeling standards? (Labeling code 4.1.2) - 1/1/1986 Extinguishers shall be located along normal paths of travel, INCLUDING exits. True or False? - True FE's weighing less than 40lb should be installed so that the top of device is no more than how far from the ground? - 5 ft Fire extinguishers shall not be further than how many feet away from flammable liquids of appreciable depth? - 50 ft General labeling types for water based extinguishers - ANSI/UL626 and CAN/ULC-S507 How long should the pressure of a hydro test be held? - 30 seconds How often are Co2 hoses supposed to be conductivity tested? - Yearly How often do master gauges or dead weight testers be calibrated? - Annually How often will pump tank water and pump tank calcium-chloride based antifreeze types of fire extinguishers be recharged with new chemicals or water as applicable? - 12 months How often will the premixed agent in liquid charge type AFFF and FFFP fire extinguishers shall be replaced how often? - Every 3 years If a conductivity test on a Co2 hose fails, what occurs? - Replacement

Vista previa del contenido

FEX Seattle Study guide
The four methods for filling liquid agent shall be determined using these to prevent overfilling -
Exact measurement by weight or volume, anti-overfill tube, fill mark on side of extinguisher



For low pressure cylinders, if pressure is not specified on nameplate, what shall they be test to, but to to
exceed three time service pressure? - factory test pressure



DOT 3A, 3AA, or 3AL cylinders used as carbon dioxide extinguishers, OR nitrogen cylinders, argon
cylinders, or carbon dioxide cylinders used with wheeled extinguishers shall be tested to what fraction of
the service pressure, when on the topic of high pressure cylinders? - 5/3



All cylinders and apparatuses, except water based, need to have what happen after testing? -
Thoroughly dried



At what temperature should extinguishers having aluminum cylinders or shells suspected of being
exposed to this temperature be removed from service and hydrotested? - >350F



Cartridge and cylinder operated dry chemical and dry powder types shall be hydro'd at what test
pressure? - Original factory test pressure



Class D hazard fire extinguisher travel distance? - 75 ft



Class K hazard maximum travel distance? - 30 ft



Cylinders (except those charged with carbon dioxide) complying with 49 CFR 180.2098(b) shall be
permitted to be hydro tested how often? - Every 10 years



Cylinders & cartridge bearing what two symbols are regulated to their own regulations - DOT and
TC

, Extinguishers manufactured prior to what date are not required to have as strict of labeling standards?
(Labeling code 4.1.2) - 1/1/1986



Extinguishers shall be located along normal paths of travel, INCLUDING exits. True or False? - True



FE's weighing less than 40lb should be installed so that the top of device is no more than how far from
the ground? - 5 ft



Fire extinguishers shall not be further than how many feet away from flammable liquids of appreciable
depth? - 50 ft



General labeling types for water based extinguishers - ANSI/UL626 and CAN/ULC-S507



How long should the pressure of a hydro test be held? - 30 seconds



How often are Co2 hoses supposed to be conductivity tested? - Yearly



How often do master gauges or dead weight testers be calibrated? - Annually



How often will pump tank water and pump tank calcium-chloride based antifreeze types of fire
extinguishers be recharged with new chemicals or water as applicable? - 12 months



How often will the premixed agent in liquid charge type AFFF and FFFP fire extinguishers shall be
replaced how often? - Every 3 years



If a conductivity test on a Co2 hose fails, what occurs? - Replacement



If using heated air to dry a cylinder after hydrotesting, what is the maximum temperature of that air? -
150

Información del documento

Subido en
20 de agosto de 2024
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$8.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Brainarium
3.8
(333)
Vendido
1977
Seguidores
1046
Artículos
23847
Última venta
2 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes