1. The function of the compressor is : - B. to lower the pressure in the evaporator so that the refrigerant temperature is lowered below the temperature of the air in the box . 2 . Forced air evaporator coils are commonly used because : - A. they absorb more heat in less time . 3 . Evaporator A operates with a 5 ° TD and evaporator B operates with a 15⁰ TD . - D. Box A operates with higher humidity than box B 4 Whenever you re soldering refrigerant lines : - D. B & C 5 . R404A must be charged into a system : - A. In a liquid state 6 . If an evaporator fan motor needs to be replaced it must be replaced with : - C. Any motor with the exact HP , speed , voltage , mounting and rotation 7 . The fan blade on an evaporator or condenser must be positioned in the housing or shroud so that : - B. The blade is mounted mid way into the evaporator housing opening or fan shroud opening on a condenser . 8. Which of the following refrigerants is an interim choice for a replacement for R - 12 in a system that had a leak in the condenser and lost all of its refrigerant ? - C. R - 409A 9 . Which refrigerant is an interim refrigerant choice for a R502 system that had a major leak in the evaporator - d . R408A 10 . When evacuating a refrigeration system what tool is needed to ensure a good evacuation and to help inform you if there is any moisture or leaks in the system : - B. Micron gauge11 . Which refrigerant would you convert a walk in freezer to if replacing the condensing unit on an R502 system : - B. R404A 12 . Which phrase best describes the proper use for a refrigerated box using a cap tube system ? - A. Storage freezer 13 . Which is the best example of the definition of a storage box ? - A. A freezer on which the door is opened 8 times a day 14 . In order to maintain proper temperature under the various loads , a cooler or freezer located on a front prep line must be equipped with : - C. A thermal expansion valve

Mostrar más Leer menos
Institución
CFESA Refrigeration Certification
Grado
CFESA Refrigeration Certification









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
CFESA Refrigeration Certification
Grado
CFESA Refrigeration Certification

Información del documento

Subido en
17 de agosto de 2024
Número de páginas
13
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

CFESA Refrigeration Certification Test
1. The function of the compressor is : - B. to lower the pressure in the evaporator so that the
refrigerant temperature is lowered below the temperature of the air in the box .



2 . Forced air evaporator coils are commonly used because : - A. they absorb more heat in less
time .



3 . Evaporator A operates with a 5 ° TD and evaporator B operates with a 15⁰ TD . - D. Box A
operates with higher humidity than box B



4 Whenever you re soldering refrigerant lines : - D. B & C



5 . R404A must be charged into a system : - A. In a liquid state



6 . If an evaporator fan motor needs to be replaced it must be replaced with : - C. Any motor with
the exact HP , speed , voltage , mounting and rotation



7 . The fan blade on an evaporator or condenser must be positioned in the housing or shroud so that : -
B. The blade is mounted mid way into the evaporator housing opening or fan shroud opening on a
condenser .



8. Which of the following refrigerants is an interim choice for a replacement for R - 12 in a system that
had a leak in the condenser and lost all of its refrigerant ? - C. R - 409A



9 . Which refrigerant is an interim refrigerant choice for a R502 system that had a major leak in the
evaporator - d . R408A



10 . When evacuating a refrigeration system what tool is needed to ensure a good evacuation and to
help inform you if there is any moisture or leaks in the system : - B. Micron gauge

, 11 . Which refrigerant would you convert a walk in freezer to if replacing the condensing unit on an R502
system : - B. R404A



12 . Which phrase best describes the proper use for a refrigerated box using a cap tube system ? -
A. Storage freezer



13 . Which is the best example of the definition of a storage box ? - A. A freezer on which the door
is opened 8 times a day



14 . In order to maintain proper temperature under the various loads , a cooler or freezer located on a
front prep line must be equipped with : - C. A thermal expansion valve



15 . A cap tube is ineffective on most commercial refrigeration systems because : - D. it cannot
respond to the refrigerant needs under heavy loads



16 . The sensor bulb on a TEV must be : - C. mounted tight to a clean surface on the suction line
close to the outlet of the coil



17 . An automatic expansion valve does not : - C. react well in situations of heavy loads .



18 . For maximum efficiency the thermal expansion valve superheat for a freezer should be about : -
A. 5 degrees



19 . For maximum system efficiency the TEV superheat for a cooler should be about : - C. 8-10
degrees



20 . What type of oil is most commonly used with CFC refrigerants ? - C. Mineral



21 . What type of oil must be used with R404A ? - D. Polyolester



22 . What pressure relates to 20 ° F on R404A ? - 56.7 psi
$7.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
PatrickKaylian Delaware State University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1820
Miembro desde
2 año
Número de seguidores
1044
Documentos
22126
Última venta
1 día hace

3.8

317 reseñas

5
147
4
60
3
54
2
16
1
40

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes