100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

ACI Test All Answers Correct

Puntuación
-
Vendido
-
Páginas
9
Grado
A+
Subido en
06-08-2024
Escrito en
2024/2025

ACI Test All Answers Correct - What is the maximum duration allowed between the first and final portions of a composite sample collection? The maximum allowable time between obtaining the first and last portions of a composite sample is 15 minutes. - Should wet sieving of a concrete sample occur after the individual samples are mixed into a composite? False. Wet sieving should not be conducted after the samples are combined; it has distinct timing requirements. - After obtaining a composite sample, within how many minutes must tests for slump, temperature, and air content commence? These tests are required to start within 5 minutes of acquiring the composite sample. - When must test specimens be molded after the composite sample collection? The molding of test specimens should occur within 15 minutes after the collection of the composite sample. - What precautions should be taken with concrete samples to prevent negative effects? Concrete samples should be safeguarded from sunlight, wind, rapid evaporation, and contamination. - What is the minimum volume of concrete sample needed for molding strength test specimens? A minimum concrete sample size of 28 liters (1 cubic foot) is required for this purpose. - Is obtaining a representative sample the main goal of the sampling process? True. Ensuring that the sample is representative is the key objective of the sampling procedure. - How many portions should be collected from a revolving drum truck mixer during sampling? Concrete should be taken from 2 or more sections of the batch when sampling from a revolving drum truck mixer. - What circumstances call for wet sieving of concrete? Wet sieving is necessary if the concrete includes aggregates larger than what is acceptable for testing. - Is it permissible to use three small containers on the subgrade when sampling from a paving mixer? False. This method is not acceptable for obtaining the required concrete samples. --- TEMPERATURE MEASUREMENTS - How long may it take for temperature stabilization when the nominal maximum size (NMS) of coarse aggregate exceeds a certain dimension? It may take up to 20 minutes for the temperature to stabilize when the NMS of coarse aggregate is greater than 3 inches. - What size container is necessary to ensure proper temperature measurement in concrete? The container must be large enough to allow for at least 3 inches (or 3 times the NMS) of concrete to surround the temperature measuring device on all sides. - What accuracy should the temperature measuring device have, and what range must it encompass? The device should accurately measure temperature within ±1°F and cover a temperature range from 30°F to 120°F. - Is a composite sample required if the only intention is to measure temperature? True. A composite sample is not necessary for determining temperature alone. - How frequently should the temperature measuring device be calibrated? The calibration must be performed annually or whenever there is doubt regarding its accuracy.

Mostrar más Leer menos
Institución
Grado









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Estudio
Grado

Información del documento

Subido en
6 de agosto de 2024
Número de páginas
9
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ACI Test All Answers Correct
- What is the maximum duration allowed between the first and final portions of a composite sample
collection?

The maximum allowable time between obtaining the first and last portions of a composite sample is 15
minutes.



- Should wet sieving of a concrete sample occur after the individual samples are mixed into a
composite?

False. Wet sieving should not be conducted after the samples are combined; it has distinct timing
requirements.



- After obtaining a composite sample, within how many minutes must tests for slump, temperature, and
air content commence?

These tests are required to start within 5 minutes of acquiring the composite sample.



- When must test specimens be molded after the composite sample collection?

The molding of test specimens should occur within 15 minutes after the collection of the composite
sample.



- What precautions should be taken with concrete samples to prevent negative effects?

Concrete samples should be safeguarded from sunlight, wind, rapid evaporation, and contamination.



- What is the minimum volume of concrete sample needed for molding strength test specimens?

A minimum concrete sample size of 28 liters (1 cubic foot) is required for this purpose.



- Is obtaining a representative sample the main goal of the sampling process?

True. Ensuring that the sample is representative is the key objective of the sampling procedure.



- How many portions should be collected from a revolving drum truck mixer during sampling?

Concrete should be taken from 2 or more sections of the batch when sampling from a revolving drum
truck mixer.

, - What circumstances call for wet sieving of concrete?

Wet sieving is necessary if the concrete includes aggregates larger than what is acceptable for testing.



- Is it permissible to use three small containers on the subgrade when sampling from a paving mixer?

False. This method is not acceptable for obtaining the required concrete samples.



---



TEMPERATURE MEASUREMENTS



- How long may it take for temperature stabilization when the nominal maximum size (NMS) of coarse
aggregate exceeds a certain dimension?

It may take up to 20 minutes for the temperature to stabilize when the NMS of coarse aggregate is
greater than 3 inches.



- What size container is necessary to ensure proper temperature measurement in concrete?

The container must be large enough to allow for at least 3 inches (or 3 times the NMS) of concrete to
surround the temperature measuring device on all sides.



- What accuracy should the temperature measuring device have, and what range must it encompass?

The device should accurately measure temperature within ±1°F and cover a temperature range from
30°F to 120°F.



- Is a composite sample required if the only intention is to measure temperature?

True. A composite sample is not necessary for determining temperature alone.



- How frequently should the temperature measuring device be calibrated?

The calibration must be performed annually or whenever there is doubt regarding its accuracy.
$12.35
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
bestscores1 Kent State University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
12
Miembro desde
1 año
Número de seguidores
0
Documentos
1369
Última venta
1 mes hace
ReadEase

Welcome to ReadEase, your ultimate resource for exam preparation. At ReadEase, we specialize in providing comprehensive study materials and resources to help you excel in your exams. Whether you're preparing for standardized tests, professional certifications, or academic assessments, our finely curated collection covers a wide range of subjects and levels. From practice tests and study guides to expert tips and strategies, we're here to support your journey to success. ReadEase is committed to availing high-quality educational content, helping you thrive and achieve your academic and professional goals. Have any questions? We're just a message away.

Lee mas Leer menos
4.3

4 reseñas

5
2
4
1
3
1
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes