EPA 608 Guaranteed Success 1. Definition of Reclaiming: - To process refrigerant to a level equal to new (virgin) product specifications as determined by chemical analysis defines: ️ Reclaiming. 2. Disposable Cylinder Disposal Method: - The proper disposal method for disposable cylinders is to ️ recover any remaining refrigerant and then render the cylinder useless, then recycle the metal. 3. Definition of Recycling: - Clean refrigerant for reuse by separating the oil from the refrigerant by passing it through one or more filter driers is the definition of: ️ Recycle. 4. GWP of R-1234ze: - The Global Warming Potential (GWP) of R-1234ze is ️ 0. 5. Hydrostatic Testing Frequency: - Reusable refrigerant containers under high pressure must be hydrostatically tested how often? ️ Every 5 years. 6. Venting Off Refrigerant Vapor: - When filling a charging cylinder with a regulated refrigerant, the refrigerant vapor that is vented off the top must be ️ recovered. 7. Example of Non-condensable: - An example of a non-condensable is ️ air. 8. Vacuum System Safety: - When a system is in deep vacuum, never ️ energize the compressor. 9. HC Refrigerant for Small Appliances: - The HC refrigerant allowed for use in new domestic small appliances is ️ R-600a. 10. Leak Rate Repair Requirement: - Leaks must be repaired on industrial process and refrigeration units with a 50-pound charge or greater when the annualized leak rate reaches ️ 30% or more. 11. Refrigerant Trace Gas Release: - What can be done with a refrigerant trace gas and nitrogen mixture after a system leak is found? ️ Release into atmosphere. 12. Classification of Common Refrigerants: - Refrigerants CFC R-12, HCFC R-22, and HFC 134a are all classified as ️ A1. 13. Evacuation Level for R-410A: - When using a recovery unit on a system containing 100 lbs of R-410A, it must be evacuated to: ️ 0" Hg. 14. Dehydration Level: - When dehydrating a system, it should be evacuated to a level of ️ 500 microns. 15. Condensing and Refrigerant Recovery: - Refrigerant should be recovered from the condenser outlet if the condenser is ️ below the receiver. 16. Action for Non-Repairable Leaking Appliance: - If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be ️ retrofitted or retired within 12 months. 17. Recovery Level for Medium Pressure System: - When recovering a medium pressure system with more than 200 lbs of refrigerant, recover to a level of: ️ 15" Hg. 18. Standard for Machine Room Safety: - The standard for machine room safety is ️ ASHRAE 15. 19. Safety Classification of HCFC-123: - The safety classification of HCFC-123 is ️ B1. 20. EPA Evacuation Level for Low Pressure Systems: - The EPA required evacuation level for recovery or recycling equipment used on low-pressure systems is ️ 25 mm of Hg absolute. 21. Equipment for Type III Certification: - What type of equipment can be worked on with Type III certification? ️ Low pressure. 22. Safety Classification of R-134A: - The safety classification of R-134A under ASHRAE Standard 34 is ️ A1. 23. Rupture Disk Burst Pressure: - The rupture disk on a low-pressure chiller has a burst pressure of ️ 15 psig. 24. Maximum Pressure for Leak Detection: - When pressurizing a low-pressure system for leak detection purposes, do not exceed ️ 10 psig. 25. Oil Used in HFC and HFO Systems: - The oil used in HFC and HFO HVACR systems is ️ Esters.

Mostrar más Leer menos
Institución
Grado









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Estudio
Grado

Información del documento

Subido en
6 de agosto de 2024
Número de páginas
9
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

EPA 608 Guaranteed Success


1. Definition of Reclaiming:

- To process refrigerant to a level equal to new (virgin) product specifications as determined by
chemical analysis defines: ✔️ Reclaiming.



2. Disposable Cylinder Disposal Method:

- The proper disposal method for disposable cylinders is to ✔️ recover any remaining refrigerant and
then render the cylinder useless, then recycle the metal.



3. Definition of Recycling:

- Clean refrigerant for reuse by separating the oil from the refrigerant by passing it through one or
more filter driers is the definition of: ✔️ Recycle.



4. GWP of R-1234ze:

- The Global Warming Potential (GWP) of R-1234ze is ✔️ 0.



5. Hydrostatic Testing Frequency:

- Reusable refrigerant containers under high pressure must be hydrostatically tested how often? ✔️
Every 5 years.



6. Venting Off Refrigerant Vapor:

- When filling a charging cylinder with a regulated refrigerant, the refrigerant vapor that is vented off
the top must be ✔️ recovered.



7. Example of Non-condensable:

- An example of a non-condensable is ✔️ air.



8. Vacuum System Safety:

- When a system is in deep vacuum, never ✔️ energize the compressor.

, 9. HC Refrigerant for Small Appliances:

- The HC refrigerant allowed for use in new domestic small appliances is ✔️ R-600a.



10. Leak Rate Repair Requirement:

- Leaks must be repaired on industrial process and refrigeration units with a 50-pound charge or
greater when the annualized leak rate reaches ✔️ 30% or more.



11. Refrigerant Trace Gas Release:

- What can be done with a refrigerant trace gas and nitrogen mixture after a system leak is found?
✔️ Release into atmosphere.



12. Classification of Common Refrigerants:

- Refrigerants CFC R-12, HCFC R-22, and HFC 134a are all classified as ✔️ A1.



13. Evacuation Level for R-410A:

- When using a recovery unit on a system containing 100 lbs of R-410A, it must be evacuated to: ✔️
0" Hg.



14. Dehydration Level:

- When dehydrating a system, it should be evacuated to a level of ✔️ 500 microns.



15. Condensing and Refrigerant Recovery:

- Refrigerant should be recovered from the condenser outlet if the condenser is ✔️ below the
receiver.



16. Action for Non-Repairable Leaking Appliance:

- If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be ✔️
retrofitted or retired within 12 months.
$11.30
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
bestscores1 Kent State University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
12
Miembro desde
1 año
Número de seguidores
0
Documentos
1369
Última venta
3 semanas hace
ReadEase

Welcome to ReadEase, your ultimate resource for exam preparation. At ReadEase, we specialize in providing comprehensive study materials and resources to help you excel in your exams. Whether you're preparing for standardized tests, professional certifications, or academic assessments, our finely curated collection covers a wide range of subjects and levels. From practice tests and study guides to expert tips and strategies, we're here to support your journey to success. ReadEase is committed to availing high-quality educational content, helping you thrive and achieve your academic and professional goals. Have any questions? We're just a message away.

Lee mas Leer menos
4.3

4 reseñas

5
2
4
1
3
1
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes