NATE Exam: Air Conditioning and Heat Pumps with Answers 100% Pass

Document preview thumbnail
Vista previa 3 fuera de 23 páginas

NATE Exam: Air Conditioning and Heat Pumps with Answers 100% Pass 1. d (All of the above: air move- ment, humidity, temperature) 2. c (+15%) 3. d (+25%) 4. b (15%) 5. b (3.2 kWh) Which of the following factors affects a customer's level of comfort? a. Air movement b. Humidity c. Temperature d. All of the above A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible capacity of a cool- ing-only system should be within % of this calculated value. a. ±10% b. +10% c. +15% d. +30% The maximum sensible cooling capacity of a heat pump should be withi

Vista previa del contenido

NATE Exam: Air Conditioning and Heat Pumps with Answers 100% Pass

1. d (All of the Which of the following factors affects a customer's level of
above: air move- comfort?
ment, humidity,
temperature) a. Air movement
b. Humidity
c. Temperature
d. All of the above

2. c (+15%) A cooling load calculation estimates the sensible heat gain
of a structure. The maximum sensible capacity of a cool-
ing-only system should be within % of this calculated
value.

a. ±10%
b. +10%
c. +15%
d. +30%

3. d (+25%) The maximum sensible cooling capacity of a heat pump
should be within % of the calculated sensible heat
gain of a structure with a large heating load.

a. ±10%
b. +15%
c. -25%
d. +25%

4. b (15%) The combined output of a heat pump and its auxiliary heat
should not exceed the calculated heat loss of a home by
more than %.

a. 10%
b. 15%
c. 20%
d. 25%

5. b (3.2 kWh) What amount of auxiliary electric heat is needed when the
output of a heat pump on a design day equals 18,800 Btuh
and the heat loss of a home is 29,700 Btuh?


,NATE Exam: Air Conditioning and Heat Pumps with Answers 100% Pass


a. 2.1 kWh
b. 3.2 kWh
c. 5.0 kWh
d. 10.9 kWh

Note: 3,413 Btu/kW

6. b (radiation) The three processes that transfer heat energy are conduc-
tion, convection, and .

a. concentration
b. radiation
c. refraction
d. static pressure

7. b (conduction) Heat transfer that occurs when substances of different
temperatures are in contact with each other is called .

a. concentration
b. conduction
c. convection
d. radiation

8. d (The refrig- What effect does raising the pressure in a sealed system
erant's boiling have on refrigerant?
point increases)
a. It becomes more difficult to subcool the liquid refrigerant
b. It becomes more difficult to superheat the refrigerant
vapor
c. The refrigerant's boiling point decreases
d. The refrigerant's boiling point increases

9. d (Suffocation What is the primary danger to people near an accidental
caused by the refrigerant release or spill?
heavier refriger-
ant displacing a. Blurred vision caused by the refrigerant vapor coming
oxygen in the air) in contact with the eyes
b. Changes in weather patterns caused by global warming
c. Damage to the food chain caused by decreased ozone


, levels in the stratosphere
d. Suffocation caused by the heavier refrigerant displacing
oxygen in the air

10. c (125°F, 80%) The maximum temperature at which refrigerant may be
stored is °F when the container is no more than
% full of liquid by volume.

a. 120°F, 60%
b. 125°F, 60%
c. 125°F, 80%
d. 135°F, 80%

11. c (Evaporator) Boiling of the refrigerant occurs in which system compo-
nent?

a. Compressor
b. Condenser
c. Evaporator
d. Metering device

12. a (It ensures that Why is superheat necessary in a system that utilizes her-
dry vapor reach- metic compressors?
es the compres-
sor so that me- a. It ensures that dry vapor reaches the compressor so
chanical damage that mechanical damage does not occur
does not occur) b. It increases system capacity
c. It prevents liquid refrigerant from gassing the metering
device
d. Superheat is necessary only when open compressors
are being used

13. d (Suction pres- When the heat load on an evaporator increases, what is
sure and dis- the effect on the system?
charge pressure
both increase) a. Suction pressure decreases and discharge pressure
increases
b. Suction pressure increases and discharge pressure
decreases

Información del documento

Subido en
4 de agosto de 2024
Número de páginas
23
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$13.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MERCYTRISHIA
3.9
(43)
Vendido
230
Seguidores
35
Artículos
14264
Última venta
1 día hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes